{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,7,20]],"date-time":"2026-07-20T19:04:06Z","timestamp":1784574246593,"version":"3.55.0"},"reference-count":27,"publisher":"SLACK, Inc.","issue":"5","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["J Refract Surg"],"published-print":{"date-parts":[[2026,5,1]]},"abstract":"<jats:sec>\n                    <jats:title>Purpose:<\/jats:title>\n                    <jats:p>To compensate for Pentacam's (Oculus Optikger\u00e4te GmbH) flaw in Implantable Collamer Lens (ICL; STAAR Surgical) vault assessment, which is the difficulty to clearly detect the ICL itself, for the improvement of Pentacam's performance in the follow-up after ICL implantation.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Methods:<\/jats:title>\n                    <jats:p>One hundred fourteen eyes that had ICL implantation at Beijing Fenglian Eyecare Beau Care Clinic were pre-screened from January to December 2024 and were randomly divided into the formula establishment group (76 eyes) and the formula validation group (38 eyes). A regression formula was worked out with the perioperative variables measured by Pentacam to best correlate with postoperative ICL vault measured by anterior segment optical coherence tomography (AS-OCT) using Pearson correlations and multiple linear regressions in the formula establishment group, and it was then tested in the validation group.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results:<\/jats:title>\n                    <jats:p>\n                      ICL vault showed significant positive linear correlations with anterior chamber volume change (\u0394ACV) (\n                      <jats:italic toggle=\"yes\">r<\/jats:italic>\n                      = 0.845,\n                      <jats:italic toggle=\"yes\">P<\/jats:italic>\n                      &lt; .001), anterior chamber depth (\n                      <jats:italic toggle=\"yes\">r<\/jats:italic>\n                      = 0.441,\n                      <jats:italic toggle=\"yes\">P<\/jats:italic>\n                      &lt; .001), and white-to-white distance (\n                      <jats:italic toggle=\"yes\">r<\/jats:italic>\n                      = 0.342,\n                      <jats:italic toggle=\"yes\">P<\/jats:italic>\n                      &lt; .01). However, there was no linear correlation between ICL vault and ICL size\/direction\/anterior chamber angle (\n                      <jats:italic toggle=\"yes\">P<\/jats:italic>\n                      &gt; .05). The estimation formula was: ICL vault (\u03bcm) = 1,710.94 \u2013 157.81 \u00d7 ICL size (mm) +13.20 \u00d7 \u0394ACV (\u03bcL). The validation results showed that the mean absolute error, median absolute error, and root mean square error were 82.27, 77.54, and 99.31 \u03bcm, respectively.\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusions:<\/jats:title>\n                    <jats:p>This study established the ICL vault estimation formula based on \u0394ACV measured by Pentacam to best correlate with vault measured by AS-OCT. It compensates for Pentacam's flaw in ICL vault assessment, which is the difficulty to clearly detect the ICL itself, and is especially valuable when AS-OCT is unavailable.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.3928\/1081597x-20260223-01","type":"journal-article","created":{"date-parts":[[2026,5,11]],"date-time":"2026-05-11T18:21:48Z","timestamp":1778523708000},"source":"Crossref","is-referenced-by-count":0,"title":["Estimating Implantable Collamer Lens Vault From Scheimpflug-Derived Postoperative Anterior Chamber Volume Change in Chinese Eyes"],"prefix":"10.3928","volume":"42","author":[{"given":"Yinan","family":"Liu","sequence":"first","affiliation":[{"name":"Department of Ophthalmology, Peking University Third Hospital, Beijing, China"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Meng","family":"Yang","sequence":"additional","affiliation":[{"name":"Beijing Fenglian Eyecare Beau Care Clinic, Beijing, China."}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Junquan","family":"Zan","sequence":"additional","affiliation":[{"name":"Beijing Fenglian Eyecare Beau Care Clinic, Beijing, China."}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Xiaoyong","family":"Chen","sequence":"additional","affiliation":[{"name":"Department of Ophthalmology, Peking University Third Hospital, Beijing, China"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"2308","reference":[{"key":"e_1_3_2_2_2","doi-asserted-by":"publisher","DOI":"10.1080\/17434440.2023.2174429"},{"key":"e_1_3_2_3_2","doi-asserted-by":"publisher","DOI":"10.2147\/OPTH.S379856"},{"key":"e_1_3_2_4_2","doi-asserted-by":"publisher","DOI":"10.1097\/ICU.0000000000001053"},{"key":"e_1_3_2_5_2","doi-asserted-by":"publisher","DOI":"10.2147\/OPTH.S188785"},{"key":"e_1_3_2_6_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.jfo.2021.03.007"},{"key":"e_1_3_2_7_2","doi-asserted-by":"publisher","DOI":"10.1186\/s12886-019-1194-y"},{"key":"e_1_3_2_8_2","doi-asserted-by":"publisher","DOI":"10.1186\/s12886-022-02758-4"},{"key":"e_1_3_2_9_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.ajo.2005.08.048"},{"key":"e_1_3_2_10_2","doi-asserted-by":"publisher","DOI":"10.1001\/archopht.123.8.1053"},{"key":"e_1_3_2_11_2","doi-asserted-by":"publisher","DOI":"10.1186\/s12938-023-01123-w"},{"key":"e_1_3_2_12_2","doi-asserted-by":"publisher","DOI":"10.1186\/s12886-023-03096-9"},{"key":"e_1_3_2_13_2","doi-asserted-by":"publisher","DOI":"10.1371\/journal.pone.0242434"},{"key":"e_1_3_2_14_2","doi-asserted-by":"publisher","DOI":"10.3928\/1081597X-20230207-03"},{"key":"e_1_3_2_15_2","doi-asserted-by":"publisher","DOI":"10.18240\/ijo.2024.07.15"},{"key":"e_1_3_2_16_2","doi-asserted-by":"publisher","DOI":"10.1097\/j.jcrs.0000000000001079"},{"key":"e_1_3_2_17_2","doi-asserted-by":"publisher","DOI":"10.3389\/fneur.2023.1136579"},{"key":"e_1_3_2_18_2","doi-asserted-by":"publisher","DOI":"10.1186\/s40662-021-00250-6"},{"key":"e_1_3_2_19_2","doi-asserted-by":"publisher","DOI":"10.1371\/journal.pone.0296811"},{"key":"e_1_3_2_20_2","doi-asserted-by":"publisher","DOI":"10.1007\/s40123-024-00891-5"},{"key":"e_1_3_2_21_2","doi-asserted-by":"publisher","DOI":"10.3389\/fmed.2021.732719"},{"key":"e_1_3_2_22_2","doi-asserted-by":"publisher","DOI":"10.1159\/000528616"},{"key":"e_1_3_2_23_2","doi-asserted-by":"publisher","DOI":"10.1007\/s00417-024-06408-x"},{"key":"e_1_3_2_24_2","doi-asserted-by":"publisher","DOI":"10.3389\/fmed.2022.1029350"},{"key":"e_1_3_2_25_2","doi-asserted-by":"publisher","DOI":"10.1167\/tvst.13.1.8"},{"key":"e_1_3_2_26_2","doi-asserted-by":"publisher","DOI":"10.1136\/bjophthalmol-2021-319618"},{"key":"e_1_3_2_27_2","doi-asserted-by":"publisher","DOI":"10.2147\/OPTH.S171576"},{"key":"e_1_3_2_28_2","doi-asserted-by":"publisher","DOI":"10.1007\/s10792-020-01381-w"}],"container-title":["Journal of Refractive Surgery"],"original-title":[],"language":"en","deposited":{"date-parts":[[2026,7,20]],"date-time":"2026-07-20T18:44:35Z","timestamp":1784573075000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.healio.com\/doi\/10.3928\/1081597X-20260223-01"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,5,1]]},"references-count":27,"journal-issue":{"issue":"5","published-print":{"date-parts":[[2026,5,1]]}},"alternative-id":["10.3928\/1081597X-20260223-01"],"URL":"https:\/\/doi.org\/10.3928\/1081597x-20260223-01","relation":{},"ISSN":["1081-597X"],"issn-type":[{"value":"1081-597X","type":"print"}],"subject":[],"published":{"date-parts":[[2026,5,1]]}}}