{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,21]],"date-time":"2026-10-21T02:10:23Z","timestamp":1792548623345,"version":"4.5.0"},"reference-count":27,"publisher":"SLACK, Inc.","issue":"7","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["J Refract Surg"],"published-print":{"date-parts":[[2026,7,1]]},"abstract":"<jats:sec>\n                    <jats:title>Purpose:<\/jats:title>\n                    <jats:p>To compare the repeatability of corneal parameters measured by anterior segment optical coherence tomography (AS-OCT) in patients with keratoconus and healthy individuals.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Methods:<\/jats:title>\n                    <jats:p>This monocentric cross-sectional study included 136 individuals in total: 95 patients with keratoconus and 41 healthy individuals. Three AS-OCT measurements were performed on the same day using the Anterion (Heidelberg Engineering). One eye per patient was randomly selected and repeatability coefficients (RCs) with two-sided 95% CIs were calculated for anterior and posterior keratometry, as well as corneal pachymetric, epithelial, and stromal parameters. The repeatability of measured parameters was compared between patients with keratoconus and healthy individuals and in different keratoconus severity groups using intra-subject variance.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results:<\/jats:title>\n                    <jats:p>\n                      The RC of maximum keratometry (Kmax) (two-sided 95% CI) was 0.33 diopters (D) (range: 0.29 to 0.39 D) in healthy eyes and 0.68 D (range: 0.62 to 0.76 D) in eyes with keratoconus. The RC of anterior Kmean was 0.19 D (range: 0.17 to 0.23 D) and 0.37 D (range: 0.33 to 0.41 D), the RC of anterior corneal astigmatism was 0.28 D (range: 0.24 to 0.33 D) and 0.43 D (range: 0.39 to 0.48 D), and the RC of minimum corneal thickness was 1.98 \u00b5m (range: 1.72 to 2.34 \u00b5m) and 2.15 \u00b5m (range: 1.96 to 2.39 \u00b5m) in healthy eyes and eyes with keratoconus, respectively. Patients with keratoconus had a lower measurement repeatability for most measured parameters, including Kmax (\n                      <jats:italic toggle=\"yes\">P<\/jats:italic>\n                      &lt; .001, Mann-Whitney\n                      <jats:italic toggle=\"yes\">U<\/jats:italic>\n                      test, two-tailed) compared to the healthy individuals. Repeatability tended to worsen with increasing keratoconus severity.\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusions:<\/jats:title>\n                    <jats:p>Although the AS-OCT demonstrated a high measurement repeatability in both healthy eyes and eyes with keratoconus, the repeatability of most evaluated parameters was slightly lower in patients with keratoconus and tended to worsen with increasing keratoconus severity.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.3928\/1081597x-20260504-03","type":"journal-article","created":{"date-parts":[[2026,7,10]],"date-time":"2026-07-10T11:31:42Z","timestamp":1783683102000},"source":"Crossref","is-referenced-by-count":1,"title":["Severity-Graded Repeatability of AS-OCT Including Epithelial and Stromal Metrics in Patients With Keratoconus Versus Healthy Individuals"],"prefix":"10.3928","volume":"42","author":[{"given":"Ramin","family":"Khoramnia","sequence":"first","affiliation":[{"name":"International Vision Correction Research Centre, Department of Ophthalmology, University of Heidelberg, Heidelberg, Germany;"},{"name":"Department of Ophthalmology, Faculty of Medicine and University Hospital Carl Gustav Carus, TU Dresden, Dresden, Germany."}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Tadas","family":"Naujokaitis","sequence":"additional","affiliation":[{"name":"International Vision Correction Research Centre, Department of Ophthalmology, University of Heidelberg, Heidelberg, Germany;"},{"name":"Department of Ophthalmology, Faculty of Medicine and University Hospital Carl Gustav Carus, TU Dresden, Dresden, Germany."}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Maximilian","family":"Friedrich","sequence":"additional","affiliation":[{"name":"International Vision Correction Research Centre, Department of Ophthalmology, University of Heidelberg, Heidelberg, Germany;"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Hyeck-Soo","family":"Son","sequence":"additional","affiliation":[{"name":"International Vision Correction Research Centre, Department of Ophthalmology, University of Heidelberg, Heidelberg, Germany;"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Gerd U.","family":"Auffarth","sequence":"additional","affiliation":[{"name":"International Vision Correction Research Centre, Department of Ophthalmology, University of Heidelberg, Heidelberg, Germany;"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Victor A.","family":"Augustin","sequence":"additional","affiliation":[{"name":"International Vision Correction Research Centre, Department of Ophthalmology, University of Heidelberg, Heidelberg, Germany;"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"2308","reference":[{"key":"e_1_3_1_2_2","article-title":"Detecting subclinical keratoconus by biomechanical analysis in tomographically regular keratoconus fellow eyes","author":"Augustin VA","unstructured":"Augustin VA, Son HS, Baur I, Zhao L, Auffarth GU, Khoramnia R. Detecting subclinical keratoconus by biomechanical analysis in tomographically regular keratoconus fellow eyes. Eur J Ophthalmol. Published online November 29, 2021. PMID:34841930","journal-title":"Eur J Ophthalmol"},{"key":"e_1_3_1_3_2","doi-asserted-by":"publisher","DOI":"10.1097\/ICO.0000000000003518"},{"key":"e_1_3_1_4_2","doi-asserted-by":"publisher","DOI":"10.1038\/s41433-024-03199-7"},{"key":"e_1_3_1_5_2","doi-asserted-by":"publisher","DOI":"10.3928\/1081597X-20200212-03"},{"key":"e_1_3_1_6_2","doi-asserted-by":"publisher","DOI":"10.3390\/diagnostics11081466"},{"key":"e_1_3_1_7_2","doi-asserted-by":"publisher","DOI":"10.1097\/APO.0000000000000333"},{"key":"e_1_3_1_8_2","doi-asserted-by":"publisher","DOI":"10.1136\/bjophthalmol-2019-314954"},{"key":"e_1_3_1_9_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.ajo.2020.06.013"},{"key":"e_1_3_1_10_2","doi-asserted-by":"publisher","DOI":"10.3928\/1081597X-20220114-02"},{"key":"e_1_3_1_11_2","doi-asserted-by":"publisher","DOI":"10.1186\/s40662-022-00290-6"},{"key":"e_1_3_1_12_2","doi-asserted-by":"publisher","DOI":"10.3928\/1081597X-20220414-01"},{"key":"e_1_3_1_13_2","doi-asserted-by":"publisher","DOI":"10.3928\/1081597X-20230606-01"},{"key":"e_1_3_1_14_2","doi-asserted-by":"publisher","DOI":"10.5005\/jp-journals-10025-1069"},{"key":"e_1_3_1_15_2","doi-asserted-by":"publisher","DOI":"10.1167\/tvst.9.9.14"},{"key":"e_1_3_1_16_2","doi-asserted-by":"publisher","DOI":"10.1136\/bmj.312.7047.1654"},{"key":"e_1_3_1_17_2","doi-asserted-by":"publisher","DOI":"10.1593\/tlo.09268"},{"key":"e_1_3_1_18_2","doi-asserted-by":"publisher","DOI":"10.1177\/112067211002000327"},{"key":"e_1_3_1_19_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.jcrs.2011.10.027"},{"key":"e_1_3_1_20_2","doi-asserted-by":"publisher","DOI":"10.1111\/aos.17557"},{"key":"e_1_3_1_21_2","doi-asserted-by":"publisher","DOI":"10.1007\/s10384-014-0338-0"},{"key":"e_1_3_1_22_2","doi-asserted-by":"publisher","DOI":"10.1038\/s41598-020-57926-7"},{"key":"e_1_3_1_23_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.ajo.2019.01.015"},{"key":"e_1_3_1_24_2","doi-asserted-by":"publisher","DOI":"10.1371\/journal.pone.0248350"},{"key":"e_1_3_1_25_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.optom.2025.100535"},{"key":"e_1_3_1_26_2","doi-asserted-by":"publisher","DOI":"10.1097\/ICO.0000000000002657"},{"key":"e_1_3_1_27_2","doi-asserted-by":"publisher","DOI":"10.3390\/life13071474"},{"key":"e_1_3_1_28_2","doi-asserted-by":"publisher","DOI":"10.3928\/1081597X-20211116-01"}],"container-title":["Journal of Refractive Surgery"],"original-title":[],"language":"en","deposited":{"date-parts":[[2026,7,10]],"date-time":"2026-07-10T11:32:03Z","timestamp":1783683123000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.healio.com\/doi\/10.3928\/1081597X-20260504-03"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,7,1]]},"references-count":27,"journal-issue":{"issue":"7","published-print":{"date-parts":[[2026,7,1]]}},"alternative-id":["10.3928\/1081597X-20260504-03"],"URL":"https:\/\/doi.org\/10.3928\/1081597x-20260504-03","relation":{},"ISSN":["1081-597X"],"issn-type":[{"value":"1081-597X","type":"print"}],"subject":[],"published":{"date-parts":[[2026,7,1]]}}}