{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,9]],"date-time":"2026-09-09T17:10:41Z","timestamp":1788973841409,"version":"build-2803163510"},"reference-count":11,"publisher":"SLACK, Inc.","issue":"9","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["J Refract Surg"],"published-print":{"date-parts":[[2026,9,1]]},"abstract":"<jats:sec>\n                    <jats:title>Purpose:<\/jats:title>\n                    <jats:p>To compare the refractive prediction accuracy of five intraocular lens (IOL) power calculation formulas in eyes undergoing secondary sutureless intrascleral fixation of a one-piece foldable IOL and to assess biometric and anatomical factors associated with prediction error (PE).<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Methods:<\/jats:title>\n                    <jats:p>This post-hoc comparative formula analysis of a prospective interventional case series (24-month follow-up) included adult patients undergoing secondary implantation of a foldable single-piece IOL. IOL power was calculated using the SRK\/T, Hoffer Q, Holladay 1, Barrett Universal II, and Kane formulas. Primary outcomes included PE, mean absolute error (MAE), and the proportion of eyes within PE of \u00b10.50 and \u00b11.00 diopters (D). Subgroup analysis using anterior segment optical coherence tomography evaluated associations between PE, IOL tilt, and decentration. Main outcome measures were MAE, proportion of eyes within PE \u00b10.50 and \u00b11.00 D, and correlation between PE and anatomical parameters (axial length, tilt, decentration).<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results:<\/jats:title>\n                    <jats:p>\n                      A total of 226 eyes were included. MAE was lowest with Barrett Universal II (0.44 \u00b1 0.37 D) and Kane (0.46 \u00b1 0.39 D) (\n                      <jats:italic toggle=\"yes\">P<\/jats:italic>\n                      &lt; .0001, analysis of variance). The proportion of eyes with PE within \u00b10.50 D was 69.0% (129 of 187) for Barrett Universal II, 66.3% (124 of 187) for Kane, 53.5% (121 of 226) for SRK\/T, 52.2% (118 of 226) for Hoffer Q, and 51.3% (116 of 226) for Holladay 1 (\n                      <jats:italic toggle=\"yes\">P<\/jats:italic>\n                      &lt; .0001, chi-square test). The proportion within \u00b11.00 D was 90.9% (170 of 187), 90.9% (170 of 187), 83.6% (189 of 226), 83.2% (188 of 226), and 82.3% (186 of 226), respectively (\n                      <jats:italic toggle=\"yes\">P<\/jats:italic>\n                      &lt; .0001, chi-square test). PE &gt;\u00b11.00 D was significantly associated with axial length &lt;22 mm (myopic shift) or &gt;26 mm (hyperopic shift) across all formulas (\n                      <jats:italic toggle=\"yes\">P<\/jats:italic>\n                      = .022). In 86 eyes, IOL tilt showed a positive correlation with PE for Kane (B = 0.136,\n                      <jats:italic toggle=\"yes\">P<\/jats:italic>\n                      &lt; .001) and a weak negative correlation for Barrett Universal II (B = \u22120.062,\n                      <jats:italic toggle=\"yes\">P<\/jats:italic>\n                      &lt; .001), whereas no significant association was found for decentration (\n                      <jats:italic toggle=\"yes\">P<\/jats:italic>\n                      &gt; .05).\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusions:<\/jats:title>\n                    <jats:p>The Barrett Universal II and Kane formulas showed significantly better refractive prediction accuracy than third-generation formulas in eyes undergoing secondary sutureless intrascleral fixation of a one-piece foldable IOL. Axial length variability and IOL tilt significantly impacted PE across all formulas, underscoring the importance of biometric and anatomical factors in surgical planning.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.3928\/1081597x-20260707-01","type":"journal-article","created":{"date-parts":[[2026,9,9]],"date-time":"2026-09-09T16:15:11Z","timestamp":1788970511000},"source":"Crossref","is-referenced-by-count":0,"title":["Comparison of IOL Power Calculation Formulas After Sutureless Intrascleral One-Piece IOL Fixation: A Post-hoc Analysis"],"prefix":"10.3928","volume":"42","author":[{"given":"Paola","family":"Marolo","sequence":"first","affiliation":[{"name":"Department of Surgical Sciences, Section of Ophthalmology, University of Turin, Turin, Italy;"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Enrico","family":"Borrelli","sequence":"additional","affiliation":[{"name":"Department of Surgical Sciences, Section of Ophthalmology, University of Turin, Turin, Italy;"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Guglielmo","family":"Parisi","sequence":"additional","affiliation":[{"name":"Department of Surgical Sciences, Section of Ophthalmology, University of Turin, Turin, Italy;"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Francesca","family":"Cimorosi","sequence":"additional","affiliation":[{"name":"Department of Surgical Sciences, Section of Ophthalmology, University of Turin, Turin, Italy;"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Federica","family":"Lo Cascio","sequence":"additional","affiliation":[{"name":"Department of Surgical Sciences, Section of Ophthalmology, University of Turin, Turin, Italy;"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Federica","family":"Trastu","sequence":"additional","affiliation":[{"name":"Department of Surgical Sciences, Section of Ophthalmology, University of Turin, Turin, Italy;"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Lorena","family":"Ulla","sequence":"additional","affiliation":[{"name":"Department of Surgical Sciences, Section of Ophthalmology, University of Turin, Turin, Italy;"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Gian Marco","family":"Tosi","sequence":"additional","affiliation":[{"name":"Ophthalmology Unit, Department of Medicine, Surgery and Neurosciences, University of Siena, Siena, Italy;"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Maria Francesca","family":"Lisa","sequence":"additional","affiliation":[{"name":"Ophthalmology Unit, Department of Medicine, Surgery and Neurosciences, University of Siena, Siena, Italy;"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Matteo","family":"Fallico","sequence":"additional","affiliation":[{"name":"Department of Ophthalmology, University of Catania, Catania, Italy;"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Mario Damiano","family":"Toro","sequence":"additional","affiliation":[{"name":"Eye Clinic, Public Health Department, University of Naples Federico II, Naples, Italy;"},{"name":"Department of General and Pediatric Ophthalmology, Medical University of Lublin, Lublin, Poland;"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Vincenza Maria Elena","family":"Bonfiglio","sequence":"additional","affiliation":[{"name":"Department of Experimental Biomedicine and Clinical Neuroscience, Ophthalmology Section, University of Palermo, Palermo, Italy."}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Michele","family":"Reibaldi","sequence":"additional","affiliation":[{"name":"Department of Surgical Sciences, Section of Ophthalmology, University of Turin, Turin, Italy;"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"2308","reference":[{"key":"e_1_3_1_2_2","doi-asserted-by":"publisher","DOI":"10.1186\/s40662-024-00414-0"},{"key":"e_1_3_1_3_2","doi-asserted-by":"publisher","DOI":"10.1186\/s40662-023-00341-6"},{"key":"e_1_3_1_4_2","doi-asserted-by":"publisher","DOI":"10.1097\/IAE.0000000000003873"},{"key":"e_1_3_1_5_2","doi-asserted-by":"publisher","DOI":"10.3928\/1081597X-20240611-04"},{"key":"e_1_3_1_6_2","doi-asserted-by":"publisher","DOI":"10.1111\/aos.15795"},{"key":"e_1_3_1_7_2","doi-asserted-by":"publisher","DOI":"10.3928\/1081597X-20210401-01"},{"key":"e_1_3_1_8_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.oret.2025.09.005"},{"key":"e_1_3_1_9_2","volume-title":"Statistical Power Analysis for the Behavioral Sciences","author":"Cohen JS","year":"1988","unstructured":"Cohen JS. Statistical Power Analysis for the Behavioral Sciences. 2nd Ed. Routledge; 1988.","edition":"2"},{"key":"e_1_3_1_10_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.jcjo.2025.01.020"},{"key":"e_1_3_1_11_2","doi-asserted-by":"publisher","DOI":"10.1111\/aos.16654"},{"key":"e_1_3_1_12_2","doi-asserted-by":"publisher","DOI":"10.1097\/j.jcrs.0000000000001592"}],"container-title":["Journal of Refractive Surgery"],"original-title":[],"language":"en","deposited":{"date-parts":[[2026,9,9]],"date-time":"2026-09-09T16:15:16Z","timestamp":1788970516000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.healio.com\/doi\/10.3928\/1081597X-20260707-01"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,9,1]]},"references-count":11,"journal-issue":{"issue":"9","published-print":{"date-parts":[[2026,9,1]]}},"alternative-id":["10.3928\/1081597X-20260707-01"],"URL":"https:\/\/doi.org\/10.3928\/1081597x-20260707-01","relation":{},"ISSN":["1081-597X"],"issn-type":[{"value":"1081-597X","type":"print"}],"subject":[],"published":{"date-parts":[[2026,9,1]]}}}