{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,9]],"date-time":"2026-09-09T17:10:46Z","timestamp":1788973846058,"version":"build-2803163510"},"reference-count":46,"publisher":"SLACK, Inc.","issue":"9","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["J Refract Surg"],"published-print":{"date-parts":[[2026,9,1]]},"abstract":"<jats:sec>\n                    <jats:title>Purpose:<\/jats:title>\n                    <jats:p>To assess the incidence and contributing factors of pseudoaccommodation in pseudophakic eyes implanted with aspherically neutral monofocal intraocular lenses (IOLs), comparing printed chart reading under standardized ambient illumination with assessment using the backlit Salzburg Reading Desk (SRD) (SRD Vision, LLC).<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Methods:<\/jats:title>\n                    <jats:p>This was a prospective, non-randomized, single-eye cohort study of patients undergoing monofocal IOL implantation for cataract surgery. Uncorrected near visual acuity (UNVA) was measured at 1 and 3 to 9 months postoperatively using both the Precision Vision Chart (chart-based, 40 cm) and the SRD (screen-based, 40 cm). Chart-based assessment was performed first, followed by SRD-based assessment, in a consistent order. Both assessments were conducted in the same room under standardized ambient illumination (\u223c500 lux). Pseudoaccommodation was defined as simultaneous uncorrected distance visual acuity (UDVA) better than 20\/40 (0.3 logarithm of the minimum angle of resolution [logMAR]) and UNVA 0.3 logMAR (J4). Binary logistic regression (backward and forward stepwise, with Firth-penalized regression as a sensitivity analysis) identified independent predictors. A worst-case attrition sensitivity analysis and a sensitivity analysis restricted to eyes within \u00b10.50 diopters (D) of emmetropia were performed.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results:<\/jats:title>\n                    <jats:p>\n                      Of 412 patients recruited, 301 (73.1%) had complete data (27.0% were lost to follow-up due to the coronavirus disease 2019 pandemic). Pseudoaccommodation occurred in 21 patients (6.9%) with printed charts versus 29 patients (9.6%) with SRD; only 9 patients (3.0%) met criteria by both methods. In a worst-case attrition analysis, rates were 5.1% (chart) and 7.0% (SRD), preserving the directional difference. Multivariable analysis revealed total spherical aberration as the sole independent predictor of chart-based pseudoaccommodation (odds ratio [OR]: 3.3 \u00d7 10\n                      <jats:sup>\u22126<\/jats:sup>\n                      , 95% CI: 0.00 to 0.08,\n                      <jats:italic toggle=\"yes\">P<\/jats:italic>\n                      = .02). For SRD-based pseudoaccommodation, independent predictors were lower (more myopic) spherical equivalent (OR: 0.49, 95% CI: 0.31 to 0.78,\n                      <jats:italic toggle=\"yes\">P<\/jats:italic>\n                      = .01), smaller mesopic pupil diameter (OR: 0.41, 95% CI: 0.24 to 0.72,\n                      <jats:italic toggle=\"yes\">P<\/jats:italic>\n                      &lt; .01), lower total spherical aberration (OR: 9.6 \u00d7 10\n                      <jats:sup>\u22126<\/jats:sup>\n                      , 95% CI: 0.00 to 0.02,\n                      <jats:italic toggle=\"yes\">P<\/jats:italic>\n                      = .01), and shorter preoperative axial length (OR: 0.40, 95% CI: 0.22 to 0.73,\n                      <jats:italic toggle=\"yes\">P<\/jats:italic>\n                      &lt; .01). In a sensitivity analysis restricted to eyes within \u00b10.50 D of emmetropia (n = 218), spherical aberration and mesopic pupil size remained significant predictors, indicating their contribution is independent of residual refractive error.\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusions:<\/jats:title>\n                    <jats:p>Pseudoaccommodation is multifactorial, with the assessment method and nature of the visual stimulus (self-luminous backlit screen versus reflective printed chart) significantly influencing its incidence and predictive factors. Spherical aberration was the sole independent predictor for chart-based pseudoaccommodation, whereas spherical equivalent, mesopic pupil size, spherical aberration, and axial length were independent predictors for SRD-based pseudoaccommodation.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.3928\/1081597x-20260714-01","type":"journal-article","created":{"date-parts":[[2026,9,9]],"date-time":"2026-09-09T16:15:11Z","timestamp":1788970511000},"source":"Crossref","is-referenced-by-count":0,"title":["Association Between Pseudoaccommodation Measured With the Salzburg Reading Desk Versus the Reading Chart in Pseudophakic Patients"],"prefix":"10.3928","volume":"42","author":[{"given":"Mayank A.","family":"Nanavaty","sequence":"first","affiliation":[{"name":"University Hospitals Sussex NHS Foundation Trust, Brighton, United Kingdom;"},{"name":"Brighton &amp; Sussex Medical School, University of Sussex, Falmer, Brighton, United Kingdom;"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ritika","family":"Mukhija","sequence":"additional","affiliation":[{"name":"University Hospitals Sussex NHS Foundation Trust, Brighton, United Kingdom;"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Zahra","family":"Ashena","sequence":"additional","affiliation":[{"name":"University Hospitals Sussex NHS Foundation Trust, Brighton, United Kingdom;"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Catey","family":"Bunce","sequence":"additional","affiliation":[{"name":"London School of Hygiene and Tropical Medicine, London, United Kingdom;"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"David J.","family":"Spalton","sequence":"additional","affiliation":[{"name":"Kings College, London, United Kingdom."}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"2308","reference":[{"key":"e_1_3_2_2_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0042-6989(98)00283-1"},{"key":"e_1_3_2_3_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0002-9394(14)77905-X"},{"key":"e_1_3_2_4_2","doi-asserted-by":"publisher","DOI":"10.1038\/s41433-025-04048-x"},{"key":"e_1_3_2_5_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.jcrs.2006.03.021"},{"key":"e_1_3_2_6_2","doi-asserted-by":"publisher","DOI":"10.1097\/j.jcrs.0000000000001302"},{"key":"e_1_3_2_7_2","doi-asserted-by":"publisher","DOI":"10.3928\/1081597X-20091119-01"},{"key":"e_1_3_2_8_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.jcrs.2013.01.031"},{"key":"e_1_3_2_9_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0886-3350(97)80155-1"},{"key":"e_1_3_2_10_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.jcrs.2011.07.032"},{"key":"e_1_3_2_11_2","doi-asserted-by":"publisher","DOI":"10.1097\/OPX.0b013e318157c6dc"},{"issue":"12","key":"e_1_3_2_12_2","first-page":"1458","article-title":"Apparent accommodation in pseudophakic eyes after implantation of posterior chamber intraocular lenses: optical analysis","volume":"25","author":"Nakazawa M","year":"1984","unstructured":"Nakazawa M, Ohtsuki K. Apparent accommodation in pseudophakic eyes after implantation of posterior chamber intraocular lenses: optical analysis. Invest Ophthalmol Vis Sci. 1984;25(12):1458\u20131460. PMID:6511231","journal-title":"Invest Ophthalmol Vis Sci"},{"key":"e_1_3_2_13_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.jcrs.2008.10.054"},{"key":"e_1_3_2_14_2","doi-asserted-by":"publisher","DOI":"10.1097\/OPX.0b013e3181559ace"},{"key":"e_1_3_2_15_2","doi-asserted-by":"publisher","DOI":"10.1167\/iovs.05-0939"},{"key":"e_1_3_2_16_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.jcrs.2010.07.022"},{"key":"e_1_3_2_17_2","doi-asserted-by":"publisher","DOI":"10.1097\/j.jcrs.0000000000000713"},{"key":"e_1_3_2_18_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.jcrs.2007.01.035"},{"key":"e_1_3_2_19_2","doi-asserted-by":"publisher","DOI":"10.3928\/1081-597X-20021101-04"},{"key":"e_1_3_2_20_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.visres.2011.05.006"},{"key":"e_1_3_2_21_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.jcrs.2007.04.019"},{"key":"e_1_3_2_22_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.jcrs.2013.02.052"},{"key":"e_1_3_2_23_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.ophtha.2007.01.024"},{"key":"e_1_3_2_24_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0886-3350(03)00334-1"},{"key":"e_1_3_2_25_2","doi-asserted-by":"publisher","DOI":"10.1097\/OPX.0b013e318198198d"},{"key":"e_1_3_2_26_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.jcrs.2008.09.012"},{"issue":"7","key":"e_1_3_2_27_2","first-page":"511","article-title":"Subjective depth-of-focus of the eye","volume":"74","author":"Atchison DA","year":"1997","unstructured":"Atchison DA, Charman WN, Woods RL. Subjective depth-of-focus of the eye. Optom Vis Sci. 1997;74(7):511\u2013520. PMID:9293519","journal-title":"Optom Vis Sci"},{"key":"e_1_3_2_28_2","doi-asserted-by":"publisher","DOI":"10.1167\/12.10.12"},{"key":"e_1_3_2_29_2","doi-asserted-by":"publisher","DOI":"10.1167\/4.4.7"},{"key":"e_1_3_2_30_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.jcrs.2013.09.010"},{"key":"e_1_3_2_31_2","doi-asserted-by":"publisher","DOI":"10.1167\/1.1.1"},{"key":"e_1_3_2_32_2","doi-asserted-by":"publisher","DOI":"10.1364\/JO-SAA.17.001697"},{"key":"e_1_3_2_33_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.jcrs.2014.06.015"},{"key":"e_1_3_2_34_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.jcrs.2010.12.041"},{"key":"e_1_3_2_35_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0161-6420(97)30127-4"},{"issue":"6","key":"e_1_3_2_36_2","first-page":"1162","article-title":"Age-related changes in human ciliary muscle and lens: a magnetic resonance imaging study","volume":"40","author":"Strenk SA","year":"1999","unstructured":"Strenk SA, Semmlow JL, Strenk LM, Munoz P, Gronlund-Jacob J, DeMarco JK. Age-related changes in human ciliary muscle and lens: a magnetic resonance imaging study. Invest Ophthalmol Vis Sci. 1999;40(6):1162\u20131169. PMID:10235549","journal-title":"Invest Ophthalmol Vis Sci"},{"key":"e_1_3_2_37_2","doi-asserted-by":"publisher","DOI":"10.1167\/9.12.20"},{"key":"e_1_3_2_38_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.jcrs.2007.10.031"},{"key":"e_1_3_2_39_2","doi-asserted-by":"publisher","DOI":"10.1097\/OPX.0b013e3182928bc6"},{"key":"e_1_3_2_40_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.jcrs.2016.06.029"},{"issue":"9","key":"e_1_3_2_41_2","first-page":"2882","article-title":"Apparent accommodation and corneal wavefront aberration in pseudophakic eyes","volume":"43","author":"Oshika T","year":"2002","unstructured":"Oshika T, Mimura T, Tanaka S, . Apparent accommodation and corneal wavefront aberration in pseudophakic eyes. Invest Ophthalmol Vis Sci. 2002;43(9):2882\u20132886. PMID:12202506","journal-title":"Invest Ophthalmol Vis Sci"},{"key":"e_1_3_2_42_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.jcrs.2009.08.024"},{"key":"e_1_3_2_43_2","doi-asserted-by":"publisher","DOI":"10.1186\/s12886-018-0963-3"},{"key":"e_1_3_2_44_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.ajo.2014.02.013"},{"key":"e_1_3_2_45_2","doi-asserted-by":"publisher","DOI":"10.1002\/j.1538-9235.1997.tb04749.x"},{"key":"e_1_3_2_46_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.jcrs.2010.03.043"},{"key":"e_1_3_2_47_2","doi-asserted-by":"publisher","DOI":"10.1177\/1120672120962030"}],"container-title":["Journal of Refractive Surgery"],"original-title":[],"language":"en","deposited":{"date-parts":[[2026,9,9]],"date-time":"2026-09-09T16:15:23Z","timestamp":1788970523000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.healio.com\/doi\/10.3928\/1081597X-20260714-01"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,9,1]]},"references-count":46,"journal-issue":{"issue":"9","published-print":{"date-parts":[[2026,9,1]]}},"alternative-id":["10.3928\/1081597X-20260714-01"],"URL":"https:\/\/doi.org\/10.3928\/1081597x-20260714-01","relation":{},"ISSN":["1081-597X"],"issn-type":[{"value":"1081-597X","type":"print"}],"subject":[],"published":{"date-parts":[[2026,9,1]]}}}