{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,9]],"date-time":"2026-09-09T17:10:50Z","timestamp":1788973850440,"version":"build-2803163510"},"reference-count":23,"publisher":"SLACK, Inc.","issue":"9","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["J Refract Surg"],"published-print":{"date-parts":[[2026,9,1]]},"abstract":"<jats:sec>\n                    <jats:title>Purpose:<\/jats:title>\n                    <jats:p>To compare the predictive accuracy of the Barrett Toric IOL formula\u2014when incorporating either Predicted or Measured posterior corneal astigmatism (PCA)\u2014with the Castrop Toric formula.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Methods:<\/jats:title>\n                    <jats:p>In this retrospective study, patients diagnosed as having age-related cataract who underwent phacoemulsification with the implantation of a monofocal non-toric IOL were reviewed. Four methods of calculating a toric IOL\u2014the Castrop formula based on Predicted PCA (C-PPCA), the Castrop formula based on Measured PCA (C-MPCA), the Barrett Toric Calculator based on Predicted PCA (B-PPCA), and the Barrett Toric Calculator based on Measured PCA (B-MPCA)\u2014were applied to calculate the predicted residual astigmatism and spherical equivalent (SE). The mean absolute astigmatic prediction error (MAPEastig), centroid of astigmatic prediction error (PE), proportion of eyes within the astigmatic prediction error of \u00b10.50, \u00b10.75, and \u00b11.00 diopters (D), and PE of SE were all calculated for the four methods.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results:<\/jats:title>\n                    <jats:p>\n                      One hundred eyes of 100 patients were reviewed. No significant differences were seen for MAPEastig (\n                      <jats:italic toggle=\"yes\">P<\/jats:italic>\n                      = .379) or the centroid vectors of astigmatic PE among the four methods (\n                      <jats:italic toggle=\"yes\">P<\/jats:italic>\n                      = .138), although the differences of the predictability rate within \u00b11.00 D were significant (\n                      <jats:italic toggle=\"yes\">P<\/jats:italic>\n                      = .008). B-PPCA and B-MPCA yielded better clinical results, with 89% and 90% of eyes achieving an astigmatic PE of less than 1.00 D, compared to that of the Castrop Calculator (\n                      <jats:italic toggle=\"yes\">P<\/jats:italic>\n                      = .006 and\n                      <jats:italic toggle=\"yes\">P<\/jats:italic>\n                      = .002, respectively). For the 71 eyes with axial length of 22 to 26 mm and anterior corneal refractive power of 42.00 to 46.00 diopters, no significant differences in the PE of SE were seen between B-PPCA and B-MPCA (\n                      <jats:italic toggle=\"yes\">P<\/jats:italic>\n                      = 1.000), or between C-PPCA and C-MPCA (\n                      <jats:italic toggle=\"yes\">P<\/jats:italic>\n                      = .078). Further comparison showed that the PE of the SE of the Castrop Calculator was significantly greater than the Barrett Toric Calculator (\n                      <jats:italic toggle=\"yes\">P<\/jats:italic>\n                      &lt; .001).\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusions:<\/jats:title>\n                    <jats:p>The current study revealed comparable outcomes of the accuracy of cylindrical power calculation between the Barrett Toric and Castrop Calculators, both using Predicted and Measured PCA mode, although the Barrett Toric Calculator showed a lower PE than the Castrop Calculator in IOL spherical power calculation.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.3928\/1081597x-20260728-02","type":"journal-article","created":{"date-parts":[[2026,9,9]],"date-time":"2026-09-09T16:15:11Z","timestamp":1788970511000},"source":"Crossref","is-referenced-by-count":0,"title":["Comparative Accuracy of the Barrett Toric Calculator With or Without the Incorporation of Posterior Corneal Astigmatism and the Castrop Formula"],"prefix":"10.3928","volume":"42","author":[{"given":"Fangyu","family":"Zhao","sequence":"first","affiliation":[{"name":"Tianjin Key Laboratory of Retinal Functions and Diseases, Tianjin Branch of National Clinical Research Center for Ocular Disease, Eye Institute and School of Optometry, Tianjin Medical University Eye Hospital, Tianjin, China."}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Yaning","family":"Li","sequence":"additional","affiliation":[{"name":"Tianjin Key Laboratory of Retinal Functions and Diseases, Tianjin Branch of National Clinical Research Center for Ocular Disease, Eye Institute and School of Optometry, Tianjin Medical University Eye Hospital, Tianjin, China."}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jiayi","family":"Shi","sequence":"additional","affiliation":[{"name":"Tianjin Key Laboratory of Retinal Functions and Diseases, Tianjin Branch of National Clinical Research Center for Ocular Disease, Eye Institute and School of Optometry, Tianjin Medical University Eye Hospital, Tianjin, China."}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Fang","family":"Tian","sequence":"additional","affiliation":[{"name":"Tianjin Key Laboratory of Retinal Functions and Diseases, Tianjin Branch of National Clinical Research Center for Ocular Disease, Eye Institute and School of Optometry, Tianjin Medical University Eye Hospital, Tianjin, China."}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Yuanfeng","family":"Jiang","sequence":"additional","affiliation":[{"name":"Tianjin Key Laboratory of Retinal Functions and Diseases, Tianjin Branch of National Clinical Research Center for Ocular Disease, Eye Institute and School of Optometry, Tianjin Medical University Eye Hospital, Tianjin, China."}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Shaochong","family":"Bu","sequence":"additional","affiliation":[{"name":"Tianjin Key Laboratory of Retinal Functions and Diseases, Tianjin Branch of National Clinical Research Center for Ocular Disease, Eye Institute and School of Optometry, Tianjin Medical University Eye Hospital, Tianjin, China."}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"2308","reference":[{"key":"e_1_3_1_2_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.jcrs.2015.11.036"},{"key":"e_1_3_1_3_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.ophtha.2010.07.033"},{"key":"e_1_3_1_4_2","doi-asserted-by":"publisher","DOI":"10.1080\/17469899.2023.2284881"},{"key":"e_1_3_1_5_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.jcrs.2012.08.036"},{"key":"e_1_3_1_6_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.jcrs.2013.06.027"},{"key":"e_1_3_1_7_2","doi-asserted-by":"publisher","DOI":"10.3928\/1081597X-20090610-07"},{"key":"e_1_3_1_8_2","doi-asserted-by":"publisher","DOI":"10.2147\/OPTH.S238686"},{"key":"e_1_3_1_9_2","doi-asserted-by":"publisher","DOI":"10.1007\/s40123-023-00799-6"},{"key":"e_1_3_1_10_2","doi-asserted-by":"publisher","DOI":"10.1007\/s00417-021-05287-w"},{"key":"e_1_3_1_11_2","doi-asserted-by":"publisher","DOI":"10.1038\/s41433-019-0489-9"},{"key":"e_1_3_1_12_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.ajo.2021.05.028"},{"key":"e_1_3_1_13_2","doi-asserted-by":"publisher","DOI":"10.2147\/OPTH.S351011"},{"key":"e_1_3_1_14_2","doi-asserted-by":"publisher","DOI":"10.1097\/j.jcrs.0000000000001178"},{"key":"e_1_3_1_15_2","doi-asserted-by":"publisher","DOI":"10.3928\/1081597X-20200930-03"},{"key":"e_1_3_1_16_2","doi-asserted-by":"publisher","DOI":"10.3928\/1081597X-20190422-02"},{"key":"e_1_3_1_17_2","doi-asserted-by":"publisher","DOI":"10.1097\/j.jcrs.0000000000001025"},{"key":"e_1_3_1_18_2","doi-asserted-by":"publisher","DOI":"10.1371\/journal.pone.0252102"},{"key":"e_1_3_1_19_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.ophtha.2017.08.027"},{"key":"e_1_3_1_20_2","doi-asserted-by":"publisher","DOI":"10.1038\/s41598-021-92354-1"},{"key":"e_1_3_1_21_2","doi-asserted-by":"publisher","DOI":"10.1186\/s12886-023-03094-x"},{"key":"e_1_3_1_22_2","doi-asserted-by":"publisher","DOI":"10.1038\/s41598-021-98491-x"},{"key":"e_1_3_1_23_2","doi-asserted-by":"publisher","DOI":"10.1007\/s00417-022-05777-5"},{"key":"e_1_3_1_24_2","doi-asserted-by":"publisher","DOI":"10.1007\/s00417-023-06367-9"}],"container-title":["Journal of Refractive Surgery"],"original-title":[],"language":"en","deposited":{"date-parts":[[2026,9,9]],"date-time":"2026-09-09T16:15:26Z","timestamp":1788970526000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.healio.com\/doi\/10.3928\/1081597X-20260728-02"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,9,1]]},"references-count":23,"journal-issue":{"issue":"9","published-print":{"date-parts":[[2026,9,1]]}},"alternative-id":["10.3928\/1081597X-20260728-02"],"URL":"https:\/\/doi.org\/10.3928\/1081597x-20260728-02","relation":{},"ISSN":["1081-597X"],"issn-type":[{"value":"1081-597X","type":"print"}],"subject":[],"published":{"date-parts":[[2026,9,1]]}}}