{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,7]],"date-time":"2026-10-07T16:59:21Z","timestamp":1791392361618,"version":"4.3.3"},"reference-count":17,"publisher":"SLACK, Inc.","issue":"10","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["J Refract Surg"],"published-print":{"date-parts":[[2026,10,1]]},"abstract":"<jats:sec>\n                    <jats:title>Purpose:<\/jats:title>\n                    <jats:p>To compare axial length (AL) measurements from a novel swept-source optical coherence tomography (SSOCT) biometer ZW-30 (sum-of-segments [SOS], traditional modes) (TowardPi Medical Technology Ltd) with the IOLMaster700 (Carl Zeiss Meditec AG), and evaluate the correlation between lens nuclear density and inter-device AL differences, as well as their impact on intraocular lens formula accuracy.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Methods:<\/jats:title>\n                    <jats:p>Patients undergoing cataract surgery with preoperative biometry performed by the ZW-30 and IOLMaster700 were included. Lens density was quantified with SS-OCT scans using ImageJ software (National Institutes of Health). Correlations between lens density and AL differences were analyzed. Refractive prediction accuracy of the Barrett Universal II (BUII), Emmetropia Verifying Optical (EVO), and the Prediction Enhanced by Artificial Intelligence and output Linearization-Debellemani\u00e8re, Gatinel, and Saad (PEARL-DGS) formulas were evaluated 1 month postoperatively. Eyes were stratified into short (&lt; 22.00 mm), medium (22.00 mm \u2264 AL &lt; 24.50 mm), and long (\u2265 24.50 mm) AL groups.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results:<\/jats:title>\n                    <jats:p>\n                      In the entire cohort (n = 74), no significant AL difference was found among the three methods (\n                      <jats:italic toggle=\"yes\">P<\/jats:italic>\n                      = .578). However, subgroup analysis revealed significant differences in medium and long eyes (both\n                      <jats:italic toggle=\"yes\">P<\/jats:italic>\n                      &lt; .01). Lens nuclear density correlated positively with AL in the entire cohort (\n                      <jats:italic toggle=\"yes\">r<\/jats:italic>\n                      = 0.39 to 0.40,\n                      <jats:italic toggle=\"yes\">P<\/jats:italic>\n                      &lt; .001) and long AL group (\n                      <jats:italic toggle=\"yes\">r<\/jats:italic>\n                      = 0.52 to 0.55,\n                      <jats:italic toggle=\"yes\">P<\/jats:italic>\n                      &lt; .05), and with AL discrepancy between ZW-30 SOS and IOLMaster 700 in long AL eyes (\n                      <jats:italic toggle=\"yes\">r<\/jats:italic>\n                      = 0.49,\n                      <jats:italic toggle=\"yes\">P<\/jats:italic>\n                      &lt; .05). No correlation was found between lens density and formula prediction error (\n                      <jats:italic toggle=\"yes\">P<\/jats:italic>\n                      &gt; .05). The EVO and BUII formulas demonstrated significantly lower mean absolute error than the PEARL-DGS formula across all measurement modes (all\n                      <jats:italic toggle=\"yes\">P<\/jats:italic>\n                      &lt; .001).\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusions:<\/jats:title>\n                    <jats:p>Agreement between the ZW-30 and IOLMaster700 appeared to decrease in medium and long eyes, with discrepancy correlating with lens density in long eyes, although this finding requires confirmation in larger samples. The EVO and BUII formulas provided favorable refractive predictions compared with the PEARL-DGS.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.3928\/1081597x-20260803-01","type":"journal-article","created":{"date-parts":[[2026,10,7]],"date-time":"2026-10-07T16:44:06Z","timestamp":1791391446000},"source":"Crossref","is-referenced-by-count":0,"title":["Correlation Between Lens Density and Inter-Method Difference in Axial Length: Sum-of-Segments Versus Traditional Method on a Novel SS-OCT Biometer and the IOLMaster 700"],"prefix":"10.3928","volume":"42","author":[{"given":"Mingzhen","family":"Yang","sequence":"first","affiliation":[{"name":"Joint Shantou International Eye Center of Shantou University and The Chinese University of Hong Kong, Shantou, China;"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Yujuan","family":"Zhang","sequence":"additional","affiliation":[{"name":"Joint Shantou International Eye Center of Shantou University and The Chinese University of Hong Kong, Shantou, China;"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Danye","family":"Mei","sequence":"additional","affiliation":[{"name":"Joint Shantou International Eye Center of Shantou University and The Chinese University of Hong Kong, Shantou, China;"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Yi","family":"Shi","sequence":"additional","affiliation":[{"name":"Joint Shantou International Eye Center of Shantou University and The Chinese University of Hong Kong, Shantou, China;"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Xin","family":"Zhong","sequence":"additional","affiliation":[{"name":"Joint Shantou International Eye Center of Shantou University and The Chinese University of Hong Kong, Shantou, China;"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Andrzej","family":"Grzybowski","sequence":"additional","affiliation":[{"name":"University of Warmia and Mazury, Olsztyn, Poland;"},{"name":"Institute for Research in Ophthalmology, Foundation for Ophthalmology Development, Poznan, Poland."}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Geng","family":"Wang","sequence":"additional","affiliation":[{"name":"Joint Shantou International Eye Center of Shantou University and The Chinese University of Hong Kong, Shantou, China;"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"2308","reference":[{"key":"e_1_3_1_2_2","doi-asserted-by":"publisher","DOI":"10.1111\/j.1755-3768.2007.00879.x"},{"key":"e_1_3_1_3_2","doi-asserted-by":"publisher","DOI":"10.1097\/j.jcrs.0000000000001601"},{"key":"e_1_3_1_4_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.jcrs.2010.02.027"},{"key":"e_1_3_1_5_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.ajo.2021.06.032"},{"key":"e_1_3_1_6_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.ajo.2011.06.012"},{"key":"e_1_3_1_7_2","doi-asserted-by":"publisher","DOI":"10.1186\/s40662-024-00377-2"},{"key":"e_1_3_1_8_2","doi-asserted-by":"publisher","DOI":"10.1136\/bjo.87.8.964"},{"key":"e_1_3_1_9_2","doi-asserted-by":"publisher","DOI":"10.1159\/000107497"},{"key":"e_1_3_1_10_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0042-6989(02)00078-0"},{"key":"e_1_3_1_11_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.jcrs.2018.08.009"},{"key":"e_1_3_1_12_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.jcrs.2017.09.028"},{"key":"e_1_3_1_13_2","doi-asserted-by":"publisher","DOI":"10.1136\/bjophthalmol-2018-312661"},{"key":"e_1_3_1_14_2","doi-asserted-by":"publisher","DOI":"10.1097\/j.jcrs.0000000000001044"},{"key":"e_1_3_1_15_2","doi-asserted-by":"publisher","DOI":"10.1159\/000496690"},{"key":"e_1_3_1_16_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.jcrs.2009.12.024"},{"key":"e_1_3_1_17_2","doi-asserted-by":"publisher","DOI":"10.1097\/j.jcrs.0000000000001466"},{"key":"e_1_3_1_18_2","doi-asserted-by":"publisher","DOI":"10.1097\/j.jcrs.0000000000001609"}],"container-title":["Journal of Refractive Surgery"],"original-title":[],"language":"en","deposited":{"date-parts":[[2026,10,7]],"date-time":"2026-10-07T16:44:14Z","timestamp":1791391454000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.healio.com\/doi\/10.3928\/1081597X-20260803-01"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,10,1]]},"references-count":17,"journal-issue":{"issue":"10","published-print":{"date-parts":[[2026,10,1]]}},"alternative-id":["10.3928\/1081597X-20260803-01"],"URL":"https:\/\/doi.org\/10.3928\/1081597x-20260803-01","relation":{},"ISSN":["1081-597X"],"issn-type":[{"value":"1081-597X","type":"print"}],"subject":[],"published":{"date-parts":[[2026,10,1]]}}}