{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,8,13]],"date-time":"2026-08-13T20:42:17Z","timestamp":1786653737523,"version":"build-2736575974"},"reference-count":13,"publisher":"SLACK, Inc.","issue":"5","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Ophthalmic Surg Lasers Imaging Retina"],"published-print":{"date-parts":[[2007,9,1]]},"abstract":"<jats:p>\n                    A 42-year-old man with Hunter syndrome developed bilateral visual field loss. Visual field testing demon strated bilateral ring scotomata that corresponded to areas of thinning seen on standard resolution optical coherence tomography. High-speed, ultrahigh resolution optical coherence tomography, capable of 3.5-micron axial resolution, showed a loss of photoreceptors outside the fovea and cystoid spaces within the inner nuclear, ganglion cell, and outer nuclear layers. These results were consistent with histopathologic features that have been reported previously in patients with Hunter syndrome. Optical coherence tomography could be used as a diagnostic modality to monitor patients with Hunter syndrome and to detect subclinical forms of disease.\n                    <jats:bold>[Ophthalmic Surg Lasers Imaging 2007;38:423\u2013428.]<\/jats:bold>\n                  <\/jats:p>","DOI":"10.3928\/15428877-20070901-14","type":"journal-article","created":{"date-parts":[[2019,10,7]],"date-time":"2019-10-07T11:45:44Z","timestamp":1570448744000},"page":"423-428","source":"Crossref","is-referenced-by-count":22,"title":["High-speed, Ultrahigh Resolution Optical Coherence Tomography of the Retina in Hunter Syndrome"],"prefix":"10.3928","volume":"38","author":[{"given":"Michael K.","family":"Yoon","sequence":"first","affiliation":[{"name":"New England Eye Center, Tufts-New England Medical Center, Tufts University, Boston, Massachusetts;"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Royce W.","family":"Chen","sequence":"additional","affiliation":[{"name":"New England Eye Center, Tufts-New England Medical Center, Tufts University, Boston, Massachusetts;"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"suffix":"III","given":"Thomas R.","family":"Hedges","sequence":"additional","affiliation":[{"name":"New England Eye Center, Tufts-New England Medical Center, Tufts University, Boston, Massachusetts;"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Vivek J.","family":"Srinivasan","sequence":"additional","affiliation":[{"name":"Department of Electrical Engineering and Computer Science and Research Laboratory of Electronics, Massachusetts Institute of Technology, Cambridge, Massachusetts;"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Iwona","family":"Gorczynska","sequence":"additional","affiliation":[{"name":"New England Eye Center, Tufts-New England Medical Center, Tufts University, Boston, Massachusetts;"},{"name":"Department of Electrical Engineering and Computer Science and Research Laboratory of Electronics, Massachusetts Institute of Technology, Cambridge, Massachusetts;"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"James G.","family":"Fujimoto","sequence":"additional","affiliation":[{"name":"Department of Electrical Engineering and Computer Science and Research Laboratory of Electronics, Massachusetts Institute of Technology, Cambridge, Massachusetts;"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Maciej","family":"Wojtkowski","sequence":"additional","affiliation":[{"name":"New England Eye Center, Tufts-New England Medical Center, Tufts University, Boston, Massachusetts;"},{"name":"Department of Electrical Engineering and Computer Science and Research Laboratory of Electronics, Massachusetts Institute of Technology, Cambridge, Massachusetts;"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Joel S.","family":"Schuman","sequence":"additional","affiliation":[{"name":"UPMC Eye Center and the Eye and Ear Institute, Ophthalmology and Visual Science Research Center, Department of Ophthalmology, University of Pittsburgh School of Medicine, Pittsburgh, Pennsylvania."}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jay S.","family":"Duker","sequence":"additional","affiliation":[{"name":"New England Eye Center, Tufts-New England Medical Center, Tufts University, Boston, Massachusetts;"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"2308","reference":[{"key":"e_1_3_1_2_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0161-6420(85)34107-6"},{"key":"e_1_3_1_3_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.ophtha.2006.05.046"},{"key":"e_1_3_1_4_2","first-page":"677","volume-title":"Optical Coherence Tomography of Ocular Diseases","author":"Fujimoto JG","year":"2004","unstructured":"Fujimoto JG, Huang D, Hee MR, . Physical properties of optical coherence tomography. In: Schuman JS, Puliafito CA, Fujimoto JG, eds. Optical Coherence Tomography of Ocular Diseases, 2nd ed. Thorofare, NJ: SLACK Incorporated; 2004:677\u2013688.","edition":"2"},{"key":"e_1_3_1_5_2","doi-asserted-by":"publisher","DOI":"10.1001\/archopht.1967.00980020505013"},{"key":"e_1_3_1_6_2","doi-asserted-by":"publisher","DOI":"10.1001\/archopht.1971.01000010166009"},{"key":"e_1_3_1_7_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0002-9394(00)00559-6"},{"key":"e_1_3_1_8_2","doi-asserted-by":"publisher","DOI":"10.1001\/archopht.1974.03900060189006"},{"key":"e_1_3_1_9_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0161-6420(86)33537-1"},{"key":"e_1_3_1_10_2","doi-asserted-by":"publisher","DOI":"10.1136\/bjo.68.8.590"},{"key":"e_1_3_1_11_2","doi-asserted-by":"publisher","DOI":"10.1001\/archopht.124.2.193"},{"key":"e_1_3_1_12_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.ophtha.2005.05.027"},{"key":"e_1_3_1_13_2","doi-asserted-by":"publisher","DOI":"10.1080\/13816810600677966"},{"key":"e_1_3_1_14_2","doi-asserted-by":"publisher","DOI":"10.1097\/01.gim.0000232477.37660.fb"}],"container-title":["Ophthalmic Surgery, Lasers and Imaging Retina"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.healio.com\/ophthalmology\/journals\/osli\/2007-9-38-5\/%7B857e9079-7255-4bdd-b595-0e46bf301308%7D\/high-speed-ultrahigh-resolution-optical-coherence-tomography-of-the-retina-in-hunter-syndrome","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,8,13]],"date-time":"2026-08-13T19:41:42Z","timestamp":1786650102000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.healio.com\/doi\/10.3928\/15428877-20070901-14"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2007,9,1]]},"references-count":13,"journal-issue":{"issue":"5","published-print":{"date-parts":[[2007,9,1]]}},"alternative-id":["10.3928\/15428877-20070901-14"],"URL":"https:\/\/doi.org\/10.3928\/15428877-20070901-14","relation":{},"ISSN":["2325-8160","2325-8179"],"issn-type":[{"value":"2325-8160","type":"print"},{"value":"2325-8179","type":"electronic"}],"subject":[],"published":{"date-parts":[[2007,9,1]]}}}