{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2023,9,9]],"date-time":"2023-09-09T13:52:12Z","timestamp":1694267532178},"reference-count":15,"publisher":"SLACK, Inc.","issue":"6","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Ophthalmic Surg Lasers Imaging"],"published-print":{"date-parts":[[2012,11]]},"abstract":"<jats:p>A 39-year-old woman with a history of high myopia underwent uneventful implantation of phakic posterior chamber implantable collamer lenses (ICLs) 6 years earlier in both eyes with a visual acuity of 20\/20 bilaterally. The patient presented as an emergency with sudden decreased vision in her right eye after blunt trauma. Slit-lamp examination showed a partially dislocated ICL in the anterior chamber, associated with ocular hypertension. It was decided to treat her with topical ocular hypotensive agents and surgical repositioning of the ICL. There was a progressive loss of endothelial cells and decreased visual acuity. Descemet stripping automated endothelial keratoplasty was needed to correct the endothelial failure. This case presents a potential complication of the ICL several years after implantation, and should be considered in these types of procedures.<\/jats:p>","DOI":"10.3928\/15428877-20120712-04","type":"journal-article","created":{"date-parts":[[2012,7,23]],"date-time":"2012-07-23T18:44:31Z","timestamp":1343069071000},"source":"Crossref","is-referenced-by-count":9,"title":["DSAEK for Implantable Collamer Lens Dislocation and Corneal Decompensation 6 Years After Implantation"],"prefix":"10.3928","volume":"43","author":[{"given":"Zoraida","family":"Espinosa-Mattar","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Arturo","family":"Gomez-Bastar","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Enrique O.","family":"Graue-Hern\u00e1ndez","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Alejandro","family":"Navas","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"2308","reference":[{"key":"e_1_3_1_2_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0161-6420(02)01771-2"},{"key":"e_1_3_1_3_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.ophtha.2004.03.026"},{"key":"e_1_3_1_4_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0886-3350(02)01210-5"},{"key":"e_1_3_1_5_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0886-3350(02)02040-0"},{"key":"e_1_3_1_6_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.jcrs.2010.04.039"},{"key":"e_1_3_1_7_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0886-3350(03)00065-8"},{"key":"e_1_3_1_8_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.ophtha.2009.12.013"},{"key":"e_1_3_1_9_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.jcrs.2008.12.027"},{"key":"e_1_3_1_10_2","doi-asserted-by":"publisher","DOI":"10.1097\/00003226-200305000-00009"},{"key":"e_1_3_1_11_2","doi-asserted-by":"publisher","DOI":"10.3928\/1081597X-20090915-08"},{"key":"e_1_3_1_12_2","doi-asserted-by":"publisher","DOI":"10.3928\/1081597X-20080601-17"},{"key":"e_1_3_1_13_2","doi-asserted-by":"publisher","DOI":"10.3928\/1081-597X-20070901-16"},{"key":"e_1_3_1_14_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.ophtha.2007.08.022"},{"key":"e_1_3_1_15_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.ophtha.2009.09.010"},{"key":"e_1_3_1_16_2","doi-asserted-by":"publisher","DOI":"10.1097\/ICO.0b013e3182035dd0"}],"container-title":["Ophthalmic Surgery, Lasers and Imaging Retina"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.healio.com\/doiresolver?doi=10.3928\/15428877-20120712-04","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,5,3]],"date-time":"2023-05-03T03:14:30Z","timestamp":1683083670000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.healio.com\/doi\/10.3928\/15428877-20120712-04"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2012,11]]},"references-count":15,"journal-issue":{"issue":"6","published-print":{"date-parts":[[2012,11]]}},"alternative-id":["10.3928\/15428877-20120712-04"],"URL":"https:\/\/doi.org\/10.3928\/15428877-20120712-04","relation":{},"ISSN":["2325-8160","2325-8179"],"issn-type":[{"value":"2325-8160","type":"print"},{"value":"2325-8179","type":"electronic"}],"subject":[],"published":{"date-parts":[[2012,11]]}}}