{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,10,1]],"date-time":"2025-10-01T16:26:40Z","timestamp":1759336000892},"reference-count":9,"publisher":"SLACK, Inc.","issue":"1","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Ophthalmic Surg Lasers Imaging Retina"],"published-print":{"date-parts":[[2014,1]]},"abstract":"<jats:sec>\n            <jats:title>BACKGROUND AND OBJECTIVE:<\/jats:title>\n            <jats:p>To evaluate B-scan and computed tomographic appearance of a wooden intraocular foreign body within the posterior segment.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>MATERIALS AND METHODS:<\/jats:title>\n            <jats:p>The authors report a case of a patient with an occult retained foreign body. To identify why the object was elusive, an in vitro study was conducted using computed tomography (CT) and B-scan on five human cadaveric eyes with known foreign bodies implanted into the vitreous cavity.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>RESULTS:<\/jats:title>\n            <jats:p>Posterior segment metal and glass produced comet tail artifacts on B-scan, whereas stone, wood, and plastic produced shadowing artifacts. There was difficulty in identifying wood within the posterior chamber via CT. However, stone and plastic were easily detectable but difficult to identify without Hounsfield units.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>CONCLUSION:<\/jats:title>\n            <jats:p>CT provides quick imaging of suspected posterior segment foreign bodies; however, B-scan ultrasonography may prove more useful than CT in detecting wooden foreign bodies.<\/jats:p>\n            <jats:p>\n              <jats:bold>\n                [\n                <jats:italic>Ophthalmic Surg Lasers Imaging Retina<\/jats:italic>\n                . 2014;45:58\u201361.]\n              <\/jats:bold>\n            <\/jats:p>\n          <\/jats:sec>","DOI":"10.3928\/23258160-20131220-09","type":"journal-article","created":{"date-parts":[[2014,2,18]],"date-time":"2014-02-18T17:07:25Z","timestamp":1392743245000},"page":"58-61","source":"Crossref","is-referenced-by-count":6,"title":["Occult Wooden Posterior Segment Intraocular Foreign Body"],"prefix":"10.3928","volume":"45","author":[{"given":"Ankit","family":"Desai","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Rohit","family":"Parihar","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Joanne","family":"Mathews","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Levent","family":"Akduman","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"2308","reference":[{"issue":"3","key":"e_1_3_1_2_2","first-page":"158","article-title":"Consensus Report: Retained Intraocular Foreign Body Consensus","volume":"26","author":"Iqbal M","year":"2010","unstructured":"Iqbal M. Consensus Report: Retained Intraocular Foreign Body Consensus. Pak J Ophthalmol. 2010;26(3):158\u2013161.","journal-title":"Pak J Ophthalmol"},{"key":"e_1_3_1_3_2","doi-asserted-by":"publisher","DOI":"10.1034\/j.1600-0420.1998.760419.x"},{"key":"e_1_3_1_4_2","doi-asserted-by":"publisher","DOI":"10.1148\/rg.286085515"},{"key":"e_1_3_1_5_2","doi-asserted-by":"publisher","DOI":"10.7863\/jum.1983.2.5.225"},{"key":"e_1_3_1_6_2","volume-title":"Ultrasound of the Eye and Orbit","author":"Byrne SF","year":"1992","unstructured":"Byrne SF, Green RL. Ultrasound of the Eye and Orbit. St. Louis: Mosby, 1992."},{"key":"e_1_3_1_7_2","unstructured":"Pieramici DJ. Open-globe injuries are rarely hopeless. Review of Ophthalmology . http:\/\/www.revophth.com\/content\/d\/retinal_insider\/i\/1315\/c\/25307\/. Published June 15 2005."},{"issue":"2","key":"e_1_3_1_8_2","first-page":"226","article-title":"The clinical significance of Hounsfield number of metallic and non-metallic foreign bodies in the soft tissue","volume":"16","author":"Choi HJ","year":"2010","unstructured":"Choi HJ, Lee HJ, Kang SG. The clinical significance of Hounsfield number of metallic and non-metallic foreign bodies in the soft tissue. Soonchunhyang Medical Science. 2010;16(2): 226\u2013230.","journal-title":"Soonchunhyang Medical Science"},{"key":"e_1_3_1_9_2","doi-asserted-by":"publisher","DOI":"10.1097\/PEC.0b013e31822d3df2"},{"key":"e_1_3_1_10_2","doi-asserted-by":"publisher","DOI":"10.1007\/s10140-007-0597-x"}],"container-title":["Ophthalmic Surgery, Lasers and Imaging Retina"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.healio.com\/doiresolver?doi=10.3928\/23258160-20131220-09","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,5,3]],"date-time":"2023-05-03T03:58:01Z","timestamp":1683086281000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.healio.com\/doi\/10.3928\/23258160-20131220-09"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2014,1]]},"references-count":9,"journal-issue":{"issue":"1","published-print":{"date-parts":[[2014,1]]}},"alternative-id":["10.3928\/23258160-20131220-09"],"URL":"https:\/\/doi.org\/10.3928\/23258160-20131220-09","relation":{},"ISSN":["2325-8160","2325-8179"],"issn-type":[{"value":"2325-8160","type":"print"},{"value":"2325-8179","type":"electronic"}],"subject":[],"published":{"date-parts":[[2014,1]]}}}