{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2023,5,3]],"date-time":"2023-05-03T04:23:03Z","timestamp":1683087783655},"reference-count":19,"publisher":"SLACK, Inc.","issue":"3","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Ophthalmic Surg Lasers Imaging Retina"],"published-print":{"date-parts":[[2014,5]]},"abstract":"<jats:sec>\n            <jats:title>BACKGROUND AND OBJECTIVE:<\/jats:title>\n            <jats:p>To investigate factors predicting duration of intraocular gas presence in 23-gauge transconjunctival sutureless vitrectomy.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>PATIENTS AND METHODS:<\/jats:title>\n            <jats:p>\n              Retrospective review of 130 eyes that underwent 23-gauge transconjunctival sutureless vitrectomy. At the end of surgery, gas exchange and sclerotomy massage to promote self-sealing were performed. If sclerotomy leakage was suspected despite sclerotomy massage, a suture was placed. Factors predicting duration of intraocular gas presence in 23-gauge transconjunctival sutureless vitrectomy were examined using multiple regression analysis. An\n              <jats:italic>F<\/jats:italic>\n              value greater than 2 and\n              <jats:italic>P<\/jats:italic>\n              value less than 0.05 were considered statistically significant.\n            <\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>RESULTS:<\/jats:title>\n            <jats:p>\n              Significant factors were axial length (\n              <jats:italic>F<\/jats:italic>\n              = 7.08;\n              <jats:italic>P<\/jats:italic>\n              &lt; .05) and IOP on postoperative day 1 (\n              <jats:italic>F<\/jats:italic>\n              = 4.35;\n              <jats:italic>P<\/jats:italic>\n              &lt; .05). Age, operation time, preoperative IOP, and number of sutured sclerotomies were not statistically significant.\n            <\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>CONCLUSION:<\/jats:title>\n            <jats:p>Factors predicting duration of intraocular gas presence in 23-gauge transconjunctival sutureless vitrectomy were axial length and postoperative IOP on day 1.<\/jats:p>\n            <jats:p>\n              <jats:bold>\n                [\n                <jats:italic>Ophthalmic Surg Lasers Imaging Retina<\/jats:italic>\n                . 2014;45:199\u2013203.]\n              <\/jats:bold>\n            <\/jats:p>\n          <\/jats:sec>","DOI":"10.3928\/23258160-20140402-02","type":"journal-article","created":{"date-parts":[[2014,5,19]],"date-time":"2014-05-19T16:56:48Z","timestamp":1400518608000},"page":"199-203","source":"Crossref","is-referenced-by-count":1,"title":["Factors Predicting Duration of Intraocular Gas Presence After 23-Gauge Transconjunctival Sutureless Vitrectomy for Rhegmatogenous Retinal Detachment"],"prefix":"10.3928","volume":"45","author":[{"given":"Hirotsugu","family":"Takashina","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Akira","family":"Watanabe","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Katsuya","family":"Mitooka","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Hiroshi","family":"Tsuneoka","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"2308","reference":[{"key":"e_1_3_1_2_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0161-6420(02)01119-3"},{"key":"e_1_3_1_3_2","doi-asserted-by":"publisher","DOI":"10.1097\/00006982-200502000-00015"},{"key":"e_1_3_1_4_2","doi-asserted-by":"publisher","DOI":"10.1097\/IAE.0b013e318162b008"},{"key":"e_1_3_1_5_2","doi-asserted-by":"publisher","DOI":"10.3928\/15428877-20070701-01"},{"key":"e_1_3_1_6_2","doi-asserted-by":"publisher","DOI":"10.1097\/01.iae.0000244272.13890.cc"},{"key":"e_1_3_1_7_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.ajo.2006.05.057"},{"key":"e_1_3_1_8_2","doi-asserted-by":"publisher","DOI":"10.3928\/15428877-20101025-02"},{"key":"e_1_3_1_9_2","doi-asserted-by":"publisher","DOI":"10.1097\/IAE.0b013e3181f0d2e6"},{"key":"e_1_3_1_10_2","doi-asserted-by":"publisher","DOI":"10.1007\/s10384-004-0214-4"},{"key":"e_1_3_1_11_2","doi-asserted-by":"publisher","DOI":"10.1097\/IAE.0b013e3181dd6da1"},{"key":"e_1_3_1_12_2","doi-asserted-by":"publisher","DOI":"10.1097\/IAE.0b013e3181e5870f"},{"key":"e_1_3_1_13_2","doi-asserted-by":"publisher","DOI":"10.1097\/IAE.0b013e318195cb28"},{"key":"e_1_3_1_14_2","doi-asserted-by":"publisher","DOI":"10.1097\/IAE.0b013e3181cea661"},{"key":"e_1_3_1_15_2","doi-asserted-by":"publisher","DOI":"10.1007\/s10384-010-0840-y"},{"key":"e_1_3_1_16_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.ophtha.2004.11.053"},{"key":"e_1_3_1_17_2","doi-asserted-by":"publisher","DOI":"10.1097\/IAE.0b013e3181ff0d77"},{"key":"e_1_3_1_18_2","doi-asserted-by":"publisher","DOI":"10.3928\/15428877-20080301-04"},{"key":"e_1_3_1_19_2","doi-asserted-by":"publisher","DOI":"10.1016\/0014-4835(88)90053-X"},{"key":"e_1_3_1_20_2","doi-asserted-by":"publisher","DOI":"10.1097\/IAE.0b013e3181e586ce"}],"container-title":["Ophthalmic Surgery, Lasers and Imaging Retina"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.healio.com\/doiresolver?doi=10.3928\/23258160-20140402-02","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,5,3]],"date-time":"2023-05-03T03:55:52Z","timestamp":1683086152000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.healio.com\/doi\/10.3928\/23258160-20140402-02"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2014,5]]},"references-count":19,"journal-issue":{"issue":"3","published-print":{"date-parts":[[2014,5]]}},"alternative-id":["10.3928\/23258160-20140402-02"],"URL":"https:\/\/doi.org\/10.3928\/23258160-20140402-02","relation":{},"ISSN":["2325-8160","2325-8179"],"issn-type":[{"value":"2325-8160","type":"print"},{"value":"2325-8179","type":"electronic"}],"subject":[],"published":{"date-parts":[[2014,5]]}}}