{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,23]],"date-time":"2026-09-23T18:03:17Z","timestamp":1790186597133,"version":"4.1.0"},"reference-count":35,"publisher":"SLACK, Inc.","issue":"5","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Ophthalmic Surg Lasers Imaging Retina"],"published-print":{"date-parts":[[2022,5,1]]},"abstract":"<jats:sec>\n                    <jats:title>OBJECTIVES:<\/jats:title>\n                    <jats:p>To describe conjunctiva and Tenon's capsule handling during the Port Delivery System with ranibizumab (PDS) implant insertion procedure including up-front assessments, planning, and instrumentation, with emphasis placed on the peritomy, scleral dissection, and closure steps.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>METHODS:<\/jats:title>\n                    <jats:p>Surgical pearls based on experience accumulated in the PDS clinical trial program in patients with retinal diseases.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>RESULTS:<\/jats:title>\n                    <jats:p>Preoperative preparation, specific instruments, and meticulous techniques are key to optimizing surgical outcomes. Before surgery, assessment of factors that affect conjunctival integrity and an in-office conjunctiva examination are conducted. Gentle, purposeful conjunctiva and Tenon's capsule handling with nontoothed forceps and suturing with a BV needle are recommended to prevent tissue damage. The peritomy is 6 mm by 6 mm, centered around the planned implant location in the superotemporal quadrant. A complete sub-Tenon's capsule dissection is achieved using a wide, robust lateral and posterior dissection technique to free tissue from the sclera and minimize tension. The globe is stabilized during scleral cutdown by grasping the sclera with fine-toothed forceps away from the incision edge to prevent tissue delamination. When closing the peritomy, both the conjunctiva and Tenon's capsule are completely captured and sutured with scleral anchoring at the apex of the peritomy to help prevent conjunctival retraction and erosion. Mitigation and detection of adverse events is critical to successful surgical outcomes.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>CONCLUSIONS:<\/jats:title>\n                    <jats:p>The PDS implant insertion procedure is straightforward, but it requires planned preoperative preparation, specific instruments, and meticulous techniques. The surgical pearls described here offer insights for optimizing outcomes.<\/jats:p>\n                    <jats:p>\n                      <jats:bold>\n                        [\n                        <jats:italic toggle=\"yes\">Ophthalmic Surg Lasers Imaging Retina<\/jats:italic>\n                        . 2022;53:266\u2013273.]\n                      <\/jats:bold>\n                    <\/jats:p>\n                  <\/jats:sec>","DOI":"10.3928\/23258160-20220415-03","type":"journal-article","created":{"date-parts":[[2022,5,16]],"date-time":"2022-05-16T10:10:15Z","timestamp":1652695815000},"page":"266-273","source":"Crossref","is-referenced-by-count":9,"title":["Conjunctiva and Tenon's Capsule Handling in the Port Delivery System with Ranibizumab Implant Insertion Procedure: Surgical Pearls"],"prefix":"10.3928","volume":"53","author":[{"given":"Jordan M.","family":"Graff","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Veeral S.","family":"Sheth","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Robert T.","family":"Chang","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Alicia R.","family":"Menezes","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Giulio","family":"Barteselli","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Varun K.","family":"Malhotra","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"2308","reference":[{"key":"e_1_3_2_2_2","doi-asserted-by":"publisher","DOI":"10.1097\/IAE.0000000000001142"},{"key":"e_1_3_2_3_2","volume-title":"38th Annual Scientific Meeting of the American Society of Retina Specialists","author":"Campochiaro P","year":"2020","unstructured":"Campochiaro P, Singh N, Kardatzke D. Primary analysis results of the phase 3 Archway trial of the Port Delivery System with ranibizumab for patients with neovascular AMD. In: 38th Annual Scientific Meeting of the American Society of Retina Specialists. 2020."},{"key":"e_1_3_2_4_2","volume-title":"SUSVIMOTM (ranibizumab injection) Instructions for use","year":"2021","unstructured":"SUSVIMOTM (ranibizumab injection) Instructions for use. Genentech, Inc., a member of the Roche Group, South San Francisco, CA. October 2021."},{"key":"e_1_3_2_5_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.ophtha.2021.09.016"},{"key":"e_1_3_2_6_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.ophtha.2019.03.036"},{"key":"e_1_3_2_7_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.oret.2020.11.004"},{"key":"e_1_3_2_8_2","unstructured":"US National Library of Medicine. Study of the efficacy and safety of the ranibizumab Port Delivery System (RPDS) for sustained delivery of ranibizumab in participants with subfoveal neovascular age-related macular degeneration (AMD). Identifier NCT02510794 2018\u20132019."},{"key":"e_1_3_2_9_2","unstructured":"US National Library of Medicine. A phase III study to evaluate the Port Delivery System with ranibizumab compared with monthly ranibizumab injections in participants with wet age-related macular degeneration. Identifier NCT03677934. 2018."},{"key":"e_1_3_2_10_2","article-title":"Glaucoma surgery: when the conjunctiva isn't ideal","author":"Piltz-Seymour JR","year":"2017","unstructured":"Piltz-Seymour JR. Glaucoma surgery: when the conjunctiva isn't ideal. Rev Ophthalmol. 6 July 2017. https:\/\/www.reviewofophthalmology.com\/article\/glaucoma-surgery-when-the-conjunctiva-isnt-ideal","journal-title":"Rev Ophthalmol"},{"key":"e_1_3_2_11_2","doi-asserted-by":"publisher","DOI":"10.3109\/02713683.2010.547648"},{"key":"e_1_3_2_12_2","doi-asserted-by":"publisher","DOI":"10.18240\/ijo.2018.07.14"},{"key":"e_1_3_2_13_2","doi-asserted-by":"publisher","DOI":"10.1023\/A:1006051725115"},{"key":"e_1_3_2_14_2","doi-asserted-by":"publisher","DOI":"10.1590\/S0004-27492007000600005"},{"key":"e_1_3_2_15_2","doi-asserted-by":"publisher","DOI":"10.1167\/iovs.03-1067"},{"key":"e_1_3_2_16_2","doi-asserted-by":"publisher","DOI":"10.3109\/02713683.2012.749916"},{"key":"e_1_3_2_17_2","doi-asserted-by":"publisher","unstructured":"Markoulli M Kolanu S. Contact lens wear and dry eyes: challenges and solutions. Clin Optom (Auckl). 2017;9:41\u201348. 10.2147\/OPTO.S111130 PMID:30214359","DOI":"10.2147\/OPTO.S111130"},{"key":"e_1_3_2_18_2","doi-asserted-by":"publisher","DOI":"10.1136\/bjo.28.11.538"},{"key":"e_1_3_2_19_2","article-title":"Glaucoma surgery 101: tips and pearls","author":"Lim MC","year":"2015","unstructured":"Lim MC. Glaucoma surgery 101: tips and pearls. Rev Ophthalmol. 5 October 2015. https:\/\/www.reviewofophthalmology.com\/article\/glaucoma-surgery-101--tips-and-pearls","journal-title":"Rev Ophthalmol"},{"key":"e_1_3_2_20_2","doi-asserted-by":"publisher","DOI":"10.1159\/000458483"},{"key":"e_1_3_2_21_2","volume-title":"Ophthalmic Surgery: Principles and Practice E-Book","author":"Spaeth G","year":"2011","unstructured":"Spaeth G, Danesh-Meyer H, Goldberg I. Ophthalmic Surgery: Principles and Practice E-Book. Elsevier Health Sciences; 2011."},{"key":"e_1_3_2_22_2","unstructured":"de Guzman MHP. Trabeculectomy. Medscape. 18 May 2020. https:\/\/emedicine.medscape.com\/article\/1844332-overview"},{"issue":"1","key":"e_1_3_2_23_2","first-page":"9","article-title":"Sub-Tenon versus peribulbar anesthesia in phacoemulsification: a comparative study","volume":"1","author":"Shahid E","year":"2013","unstructured":"Shahid E, Afaq A, Juzar UT, Ansari Z, Sharif U, Hasan K. Sub-Tenon versus peribulbar anesthesia in phacoemulsification: a comparative study. Int J Ophthalmol Eye Res. 2013;1(1):9\u201313.","journal-title":"Int J Ophthalmol Eye Res"},{"key":"e_1_3_2_24_2","doi-asserted-by":"publisher","DOI":"10.1038\/eye.1989.16"},{"key":"e_1_3_2_25_2","doi-asserted-by":"publisher","DOI":"10.1007\/978-3-540-68041-3_10"},{"key":"e_1_3_2_26_2","doi-asserted-by":"publisher","DOI":"10.1007\/978-3-540-68041-3_3"},{"key":"e_1_3_2_27_2","doi-asserted-by":"publisher","DOI":"10.1136\/bjo.74.9.519"},{"key":"e_1_3_2_28_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.ajo.2015.11.023"},{"key":"e_1_3_2_29_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.ajo.2011.10.024"},{"key":"e_1_3_2_30_2","doi-asserted-by":"publisher","DOI":"10.1177\/112067211002000117"},{"key":"e_1_3_2_31_2","doi-asserted-by":"publisher","DOI":"10.4103\/2008-322X.180703"},{"key":"e_1_3_2_32_2","doi-asserted-by":"publisher","DOI":"10.2147\/OPTH.S104029"},{"key":"e_1_3_2_33_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0161-6420(00)00521-2"},{"key":"e_1_3_2_34_2","doi-asserted-by":"publisher","DOI":"10.1111\/j.1442-9071.2012.02769.x"},{"key":"e_1_3_2_35_2","doi-asserted-by":"publisher","DOI":"10.1001\/archopht.117.9.1243"},{"key":"e_1_3_2_36_2","doi-asserted-by":"publisher","DOI":"10.1186\/s12886-018-0721-6"}],"container-title":["Ophthalmic Surgery, Lasers and Imaging Retina"],"original-title":[],"language":"en","deposited":{"date-parts":[[2026,7,8]],"date-time":"2026-07-08T16:47:03Z","timestamp":1783529223000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.healio.com\/doi\/10.3928\/23258160-20220415-03"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2022,5,1]]},"references-count":35,"journal-issue":{"issue":"5","published-print":{"date-parts":[[2022,5,1]]}},"alternative-id":["10.3928\/23258160-20220415-03"],"URL":"https:\/\/doi.org\/10.3928\/23258160-20220415-03","relation":{},"ISSN":["2325-8160","2325-8179"],"issn-type":[{"value":"2325-8160","type":"print"},{"value":"2325-8179","type":"electronic"}],"subject":[],"published":{"date-parts":[[2022,5,1]]}}}