{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,24]],"date-time":"2026-10-24T17:58:36Z","timestamp":1792864716332,"version":"4.5.0"},"reference-count":30,"publisher":"Japanese Society for Dental Materials and Devices","issue":"1","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Dental Materials Journal","Dent. Mater. J."],"published-print":{"date-parts":[[2015]]},"DOI":"10.4012\/dmj.2013-345","type":"journal-article","created":{"date-parts":[[2014,10,9]],"date-time":"2014-10-09T23:29:00Z","timestamp":1412897340000},"page":"7-12","source":"Crossref","is-referenced-by-count":137,"title":["Three-unit reinforced polyetheretherketone composite FDPs: Influence of fabrication method on load-bearing capacity and failure types"],"prefix":"10.4012","volume":"34","author":[{"given":"Bogna","family":"STAWARCZYK","sequence":"first","affiliation":[{"name":"Department of Prosthodontics, Dental School, Ludwig-Maximilians-University Munich"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Marlis","family":"EICHBERGER","sequence":"additional","affiliation":[{"name":"Department of Prosthodontics, Dental School, Ludwig-Maximilians-University Munich"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Julia","family":"UHRENBACHER","sequence":"additional","affiliation":[{"name":"Department of Prosthodontics, Dental School, Ludwig-Maximilians-University Munich"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Timea","family":"WIMMER","sequence":"additional","affiliation":[{"name":"Department of Prosthodontics, Dental School, Ludwig-Maximilians-University Munich"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Daniel","family":"EDELHOFF","sequence":"additional","affiliation":[{"name":"Department of Prosthodontics, Dental School, Ludwig-Maximilians-University Munich"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Patrick R.","family":"SCHMIDLIN","sequence":"additional","affiliation":[{"name":"Clinic of Preventive Dentistry, Periodontology and Cariology, Center of Dental Medicine, University of Zurich"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"2427","reference":[{"key":"1","unstructured":"1) Gracis SE, Nichols JI, Chalupnik JD, Yuodelis RA. Shockabsorbing behavior of five restorative materials used on implants. Int J Prosthodont 1991; 4: 282-291."},{"key":"2","doi-asserted-by":"crossref","unstructured":"2) Magne P, Schlichting LH, Maia HP, Baratieri LN. In vitro fatigue resistance of CAD\/CAM resin composite and ceramic posterior occlusal veneers. J Prosthet Dent 2010; 104: 149-157.","DOI":"10.1016\/S0022-3913(10)60111-4"},{"key":"3","doi-asserted-by":"crossref","unstructured":"3) Alt V, Hannig M, W\u00f6stmann B, Balkenhol M. Fracture strength of temporary fixed partial dentures: CAD\/CAM versus directly fabricated restorations. Dent Mater 2011; 27: 339-347.","DOI":"10.1016\/j.dental.2010.11.012"},{"key":"4","doi-asserted-by":"crossref","unstructured":"4) G\u00f6nc\u00fc Ba\u015faran E, Ayna E, Vallittu PK, Lassila LVJ. Loadbearing capacity of handmade and computer-aided design computer-aided manufacturing-fabricated three-unit fixed dental prostheses of particulate filler composite. Acta Odontol Scand 2011; 69: 144-150.","DOI":"10.3109\/00016357.2010.545034"},{"key":"5","doi-asserted-by":"crossref","unstructured":"5) Stawarczyk B, Ender A, Trottmann A, \u00d6zcan M, Fischer J, H\u00e4mmerle CH. Load-bearing capacity of CAD\/CAM milled polymeric three-unit fixed dental prostheses: Effect of aging regimens. Clin Oral Investig 2012; 16: 1669-1677.","DOI":"10.1007\/s00784-011-0670-4"},{"key":"6","doi-asserted-by":"crossref","unstructured":"6) Magne P, Silva M, Oderich E, Boff LL, Encisco R. Damping behavior of implant-supported restorations. Clin Oral Implants Res 2013; 24: 143-148.","DOI":"10.1111\/j.1600-0501.2011.02311.x"},{"key":"7","doi-asserted-by":"crossref","unstructured":"7) Stawarczyk B, Sener B, Trottmann A, Roos M, \u00d6zcan M, H\u00e4mmerle CH. Discoloration of manually fabricated resins and industrially fabricated CAD\/CAM blocks versus glassceramic: Effect of storage media, duration, and subsequent polishing. Dent Mater J 2012; 31: 377-383.","DOI":"10.4012\/dmj.2011-238"},{"key":"8","doi-asserted-by":"crossref","unstructured":"8) Stawarczyk B, \u00d6zcan M, Trottmann A, Schmutz F, Roos M, H\u00e4mmerle CH. Two-body wear rate of CAD\/CAM resin blocks and their enamel antagonists. J Prosthet Dent 2013; 109: 325-332.","DOI":"10.1016\/S0022-3913(13)60309-1"},{"key":"9","doi-asserted-by":"crossref","unstructured":"9) Fasbinder DJ, Dennison JB, Heys DR, Lampe K. The clinical performance of CAD\/CAM-generated composite inlays. J Am Dent Assoc 2005; 136: 1714-1723.","DOI":"10.14219\/jada.archive.2005.0116"},{"key":"10","unstructured":"10) Lehmann F, Spiegl K, Eickemeyer G, Rammelsberg P. Adhesively luted, metal-free composite crowns after five years. J Adhes Dent 2009; 11: 493-498."},{"key":"11","unstructured":"11) Vanoorbeek S, Vandamme K, Lijnen I, Naert I. Computeraided designed\/computer-assisted manufactured composite resin versus ceramic single-tooth restorations: A 3-year clinical study. Int J Prosthodont 2010; 23: 223-230."},{"key":"12","doi-asserted-by":"crossref","unstructured":"12) M\u00f6rmann WH, Stawarczyk B, Ender A, Sener B, Attin T, Mehl A. Wear characteristics of current aesthetic dental restorative CAD\/CAM materials: two-body wear, gloss retention, roughness and Martens hardness. J Mech Behav Biomed Mater 2013; 20: 113-125.","DOI":"10.1016\/j.jmbbm.2013.01.003"},{"key":"13","doi-asserted-by":"crossref","unstructured":"13) Toth JM, Wang M, Estes BT, Scifert JL, Seim HB. 3rd, Turner AS. Polyetheretherketone as a biomaterial for spinal applications. Biomaterials 2006; 27: 324-334.","DOI":"10.1016\/j.biomaterials.2005.07.011"},{"key":"14","doi-asserted-by":"crossref","unstructured":"14) Kurtz SM, Devine JN. PEEK biomaterials in trauma, orthopedic, and spinal implants. Biomaterials 2007; 28: 4845-4869.","DOI":"10.1016\/j.biomaterials.2007.07.013"},{"key":"15","doi-asserted-by":"crossref","unstructured":"15) Tetelman ED, Babbush CA. A new transitional abutment for immediate aestehetics and function. Implant Dent 2008; 17: 51-58.","DOI":"10.1097\/ID.0b013e318167648c"},{"key":"16","doi-asserted-by":"crossref","unstructured":"16) Bayer S, Komor N, Kramer A, Albrecht D, Mericske-Stern R, Enkling N. Retention force of plastic clips on implant bars: a randomized controlled trial. Clin Oral Implants Res 2012; 23: 1377-1384.","DOI":"10.1111\/j.1600-0501.2011.02312.x"},{"key":"17","doi-asserted-by":"crossref","unstructured":"17) Santing HJ, Meijer HJ, Raghoebar GM, Ozcan M. Fracture strength and failure mode of maxillary implant-supported provisional single crowns: a comparison of composite resin crowns fabricated directly over PEEK abutments and solid titanium abutments. Clin Implant Dent Relat Res 2012; 14: 882-889.","DOI":"10.1111\/j.1708-8208.2010.00322.x"},{"key":"18","doi-asserted-by":"crossref","unstructured":"18) Tannous F, Steiner M, Shahin R, Kern M. Retentive forces and fatigue resistance of thermoplastic resin clasps. Dent Mater 2012; 28: 273-278.","DOI":"10.1016\/j.dental.2011.10.016"},{"key":"19","doi-asserted-by":"crossref","unstructured":"19) Stawarczyk B, Beuer F, Wimmer T, Jahn D, Sener B, Roos M, Schmidlin PR. Polyetheretherketone \u2013 A suitable material for fixed dental prostheses? J Biomed Mater Res B Appl Biomater 2013; 101: 1209-1216.","DOI":"10.1002\/jbm.b.32932"},{"key":"20","doi-asserted-by":"crossref","unstructured":"20) Hallinan AJ. A Review of the Weibull Distribution. J Qual Technol 1993; 25: 85-93.","DOI":"10.1080\/00224065.1993.11979431"},{"key":"21","doi-asserted-by":"crossref","unstructured":"21) Pfeiffer P, Grube L. Effect of pontic height on the fracture strength of reinforced interim fixed partial dentures. Dent Mater 2006; 22: 1093-1097.","DOI":"10.1016\/j.dental.2005.09.003"},{"key":"22","unstructured":"22) Invibio Biomaterial Polymer Solutions. New material options for innovation in restorative and prosthetic dentistry. 2011."},{"key":"23","unstructured":"23) Ivoclar Vivadent. Lithium disilicate (LS2) Scientific Report. 2011."},{"key":"24","doi-asserted-by":"crossref","unstructured":"24) Beuer F, Steff B, Naumann M, Sorensen JA. Load-bearing capacity of all-ceramic three-unit fixed partial dentures with different computer-aided design (CAD)\/ computer-aided manufacturing (CAM) fabricated materials. Eur J Oral Sci 2009; 116: 381-386.","DOI":"10.1111\/j.1600-0722.2008.00551.x"},{"key":"25","doi-asserted-by":"crossref","unstructured":"25) Kolbeck C, Behr M, Rosentritt M, Handel G. Fracture force of tooth-tooth- and implant-tooth-supported all-ceramic fixed partial dentures using titanium vs. customised zirconia implant abutments. Clin Oral Implants Res 2008; 19: 1049-1053.","DOI":"10.1111\/j.1600-0501.2008.01551.x"},{"key":"26","doi-asserted-by":"crossref","unstructured":"26) Weibull A. A statistic distribution function of wide applicability. J Appl Mech 1951; 18: 293-297.","DOI":"10.1115\/1.4010337"},{"key":"27","doi-asserted-by":"crossref","unstructured":"27) Fischer H, Weber M, Eck M, Erdrich A, Marx R. Finite element and experimental analyses of polymer-based dental bridges reinforced by ceramic bars. J Biomech 2004; 37: 289-294.","DOI":"10.1016\/j.jbiomech.2003.08.013"},{"key":"28","doi-asserted-by":"crossref","unstructured":"28) Mahmood DJ, Linderoth EH, Vult von Steyern P. The influence of support properties and complexity on fracture strength and fracture mode of all-ceramic fixed dental protheses. Acta Odont Scand 2011; 69: 229-237.","DOI":"10.3109\/00016357.2010.549508"},{"key":"29","unstructured":"29) Scherrer SS, de Rijk W.G. The fracture resistance of allceramic crowns on supporting structures with different elastic moduli. Int J Prosthodont 1993; 6: 462-467."},{"key":"30","doi-asserted-by":"crossref","unstructured":"30) Keulemans F, Lassila LV, Garoushi S, Vallittu PK, Kleverlaan CJ, Feilzer AJ. The influence of framework design on the load-bearing capacity of laboratory-made inlay-retained fibre-reinforced composite fixed dental prostheses. J Biomech 2009; 42: 844-849.","DOI":"10.1016\/j.jbiomech.2009.01.037"}],"container-title":["Dental Materials Journal"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.jstage.jst.go.jp\/article\/dmj\/34\/1\/34_2013-345\/_pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2022,4,19]],"date-time":"2022-04-19T18:44:15Z","timestamp":1650393855000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.jstage.jst.go.jp\/article\/dmj\/34\/1\/34_2013-345\/_article"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2015]]},"references-count":30,"journal-issue":{"issue":"1","published-print":{"date-parts":[[2015]]}},"URL":"https:\/\/doi.org\/10.4012\/dmj.2013-345","relation":{},"ISSN":["0287-4547","1881-1361"],"issn-type":[{"value":"0287-4547","type":"print"},{"value":"1881-1361","type":"electronic"}],"subject":[],"published":{"date-parts":[[2015]]}}}