{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,1,18]],"date-time":"2026-01-18T20:55:30Z","timestamp":1768769730921,"version":"3.49.0"},"reference-count":42,"publisher":"Japanese Society for Dental Materials and Devices","issue":"2","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Dent. Mater. J.","Dental Materials Journal"],"published-print":{"date-parts":[[2023,3,25]]},"DOI":"10.4012\/dmj.2022-163","type":"journal-article","created":{"date-parts":[[2022,12,2]],"date-time":"2022-12-02T22:12:59Z","timestamp":1670019179000},"page":"177-186","source":"Crossref","is-referenced-by-count":1,"title":["A statistical model of the rate-dependent fracture behavior of dental polymer-based biomaterials"],"prefix":"10.4012","volume":"42","author":[{"given":"Peer","family":"SCHRADER","sequence":"first","affiliation":[{"name":"Institute of Mechanics and Materials, Technische Hochschule Mittelhessen"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Alexander","family":"SCHMIDT","sequence":"additional","affiliation":[{"name":"Department of Prosthodontics, Dental Clinic, Justus Liebig University Giessen"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Maximiliane A.","family":"SCHLENZ","sequence":"additional","affiliation":[{"name":"Department of Prosthodontics, Dental Clinic, Justus Liebig University Giessen"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Stefan","family":"KOLLING","sequence":"additional","affiliation":[{"name":"Institute of Mechanics and Materials, Technische Hochschule Mittelhessen"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Bernd","family":"W\u00d6STMANN","sequence":"additional","affiliation":[{"name":"Department of Prosthodontics, Dental Clinic, Justus Liebig University Giessen"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Marcel","family":"BERLINGER","sequence":"additional","affiliation":[{"name":"Institute of Mechanics and Materials, Technische Hochschule Mittelhessen"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"2427","reference":[{"key":"1","doi-asserted-by":"crossref","unstructured":"1) Frazer RQ, Byron RT, Osborne PB, West KP. PMMA: An essential material in medicine and dentistry. J Long Term Eff Med Implants 2005; 15: 629-639.","DOI":"10.1615\/JLongTermEffMedImplants.v15.i6.60"},{"key":"2","doi-asserted-by":"crossref","unstructured":"2) Richeton J, Ahzi S, Vecchio KS, Jiang FC, Adharapurapu RR. Influence of temperature and strain rate on the mechanical behavior of three amorphous polymers: Characterization and modeling of the compressive yield stress. Int J Solids Struct 2006; 43: 2318-2335.","DOI":"10.1016\/j.ijsolstr.2005.06.040"},{"key":"3","doi-asserted-by":"crossref","unstructured":"3) Vallo CI. Flexural strength distribution of a PMMA-based bone cement. J Biomed Mater Res 2002; 63: 226-236.","DOI":"10.1002\/jbm.10129"},{"key":"4","doi-asserted-by":"crossref","unstructured":"4) Vallo CI. Influence of load type on flexural strength of a bone cement based on PMMA. Polym Test 2002; 21: 793-800.","DOI":"10.1016\/S0142-9418(02)00013-2"},{"key":"5","unstructured":"5) Kraft J. Polymethylmethacrylate \u2014A review. J Foot Surg 1977; 16: 66-68."},{"key":"6","doi-asserted-by":"crossref","unstructured":"6) Lloyd AW, Faragher RG, Denyer SP. Ocular biomaterials and implants. Biomaterials 2001; 22: 769-785.","DOI":"10.1016\/S0142-9612(00)00237-4"},{"key":"7","doi-asserted-by":"crossref","unstructured":"7) G\u00fcth J-F, Zuch T, Zwinge S, Engels J, Stimmelmayr M, Edelhoff D. Optical properties of manually and CAD\/CAM-fabricated polymers. Dent Mater J 2013; 32: 865-871.","DOI":"10.4012\/dmj.2013-099"},{"key":"8","doi-asserted-by":"crossref","unstructured":"8) Kelvin Khng KY, Ettinger RL, Armstrong SR, Lindquist T, Gratton DG, Qian F. In vitro evaluation of the marginal integrity of CAD\/CAM interim crowns. J Prosthet Dent 2016; 115: 617-623.","DOI":"10.1016\/j.prosdent.2015.10.002"},{"key":"9","doi-asserted-by":"crossref","unstructured":"9) Rosentritt M, Raab P, Hahnel S, St\u00f6ckle M, Preis V. In-vitro performance of CAD\/CAM-fabricated implant-supported temporary crowns. Clin Oral Investig 2017; 21: 2581-2587.","DOI":"10.1007\/s00784-017-2057-7"},{"key":"10","doi-asserted-by":"crossref","unstructured":"10) Wiegand A, Stucki L, Hoffmann R, Attin T, Stawarczyk B.Repairability of CAD\/CAM high-density PMMA- and composite-based polymers. Clin Oral Investig 2015; 19: 2007-2013.","DOI":"10.1007\/s00784-015-1411-x"},{"key":"11","doi-asserted-by":"crossref","unstructured":"11) Yao J, Li J, Wang Y, Huang H. Comparison of the flexural strength and marginal accuracy of traditional and CAD\/CAM interim materials before and after thermal cycling. J Prosthet Dent 2014; 112: 649-657.","DOI":"10.1016\/j.prosdent.2014.01.012"},{"key":"12","doi-asserted-by":"crossref","unstructured":"12) Herr\u00e1ez-Galindo C, Rizo-Gorrita M, Maza-Solano S, Serrera-Figallo M-A, Torres-Lagares D. A review on CAD\/CAM yttria-stabilized tetragonal zirconia polycrystal (Y-TZP) and polymethyl methacrylate (PMMA) and their biological behavior. Polymers (Basel) 2022; 14: 906.","DOI":"10.3390\/polym14050906"},{"key":"13","doi-asserted-by":"crossref","unstructured":"13) Ionescu RN, Totan AR, Imre MM, \u021a\u00e2ncu AMC, Pantea M, Butucescu M, <i>et al.<\/i> Prosthetic materials used for implant-supported restorations and their biochemical oral interactions: A narrative review. Materials (Basel) 2022; 15: 1016.","DOI":"10.3390\/ma15031016"},{"key":"14","doi-asserted-by":"crossref","unstructured":"14) Gu Y, Bai Y, Xie X. Bite force transducers and measurement devices. Front Bioeng Biotechnol 2021; 9: 665081.","DOI":"10.3389\/fbioe.2021.665081"},{"key":"15","unstructured":"15) Larson TD. The effect of occlusal forces on restorations. Northwest Dent 2012; 91: 25-7, 29-35."},{"key":"16","doi-asserted-by":"crossref","unstructured":"16) Hou R, Zhou H, Hu K, Ding Y, Yang X, Xu G, <i>et al. <\/i>Thorough documentation of the accidental aspiration and ingestion of foreign objects during dental procedure is necessary: Review and analysis of 617 cases. Head Face Med 2016; 12 : 23.","DOI":"10.1186\/s13005-016-0120-2"},{"key":"17","doi-asserted-by":"crossref","unstructured":"17) Schrader P, Kolling S, Schlenz MA, W\u00f6stmann B, Schmidt A. Finite element simulation of fixed dental prostheses made from PMMA \u2014Part II: Material modeling and nonlinear finite element analysis. Dent Mater J 2021; 40: 894-902.","DOI":"10.4012\/dmj.2020-231"},{"key":"18","doi-asserted-by":"crossref","unstructured":"18) Iacono F, Pirani C, Arias A, de la Macorra JC, Generali L, Gandolfi MG, <i>et al.<\/i> Impact of a modified motion on the fatigue life of NiTi reciprocating instruments: A Weibull analysis. Clin Oral Investig 2019; 23: 3095-3102.","DOI":"10.1007\/s00784-018-2730-5"},{"key":"19","doi-asserted-by":"crossref","unstructured":"19) Yamaguchi S, Kani R, Kawakami K, Tsuji M, Inoue S, Lee C, <i>et al.<\/i> Fatigue behavior and crack initiation of CAD\/CAM resin composite molar crowns. Dent Mater 2018; 34: 1578-1584.","DOI":"10.1016\/j.dental.2018.07.002"},{"key":"20","unstructured":"20) Gon\u00e7alves TMSV, Teixeira KN, de Oliveira JMD, Gama LT, Bortolini S, Philippi AG. Surface treatments to improve the repair of acrylic and bis-acryl provisional materials. Am J Dent 2018; 31: 199-204."},{"key":"21","doi-asserted-by":"crossref","unstructured":"21) Quinn JB, Quinn GD. A practical and systematic review of Weibull statistics for reporting strengths of dental materials. Dent Mater 2010; 26: 135-147.","DOI":"10.1016\/j.dental.2009.09.006"},{"key":"22","doi-asserted-by":"crossref","unstructured":"22) Zucuni CP, Guilardi LF, Rippe MP, Pereira GKR, Valandro LF. Polishing of ground Y-TZP ceramic is mandatory for improving the mechanical behavior. Braz Dent J 2018; 29: 483-491.","DOI":"10.1590\/0103-6440201802044"},{"key":"23","doi-asserted-by":"crossref","unstructured":"23) Brokmann C, Berlinger M, Schrader P, Kolling S. Fraktographische Bruchspannungs \u2014Analyse von Acrylglas. ce\/papers 2019; 3: 225-237.","DOI":"10.1002\/cepa.1013"},{"key":"24","doi-asserted-by":"crossref","unstructured":"24) Schmidt A, Schrader P, Schlenz MA, W\u00f6stmann B, Kolling S. Is the assumption of linear elasticity within prosthodontics valid for polymers? \u2014An exemplary study of possible problems. Dent Mater J 2021; 40: 52-60.","DOI":"10.4012\/dmj.2019-373"},{"key":"25","doi-asserted-by":"crossref","unstructured":"25) Mulliken AD, Boyce MC. Mechanics of the rate-dependent elastic\u2013plastic deformation of glassy polymers from low to high strain rates. Int J Solids Struct 2006; 43: 1331-1356.","DOI":"10.1016\/j.ijsolstr.2005.04.016"},{"key":"26","doi-asserted-by":"crossref","unstructured":"26) Wu H, Ma G, Xia Y. Experimental study of tensile properties of PMMA at intermediate strain rate. Mater Lett 2004; 58: 3681-3685.","DOI":"10.1016\/j.matlet.2004.07.022"},{"key":"27","doi-asserted-by":"crossref","unstructured":"27) Fleck NA, Stronge WJ, Liu JH. High strain-rate shear response of polycarbonate and polymethyl methacrylate. Proc R Soc Lond A 1990; 429: 459-479.","DOI":"10.1098\/rspa.1990.0069"},{"key":"28","doi-asserted-by":"crossref","unstructured":"28) Bauwens-Crowet C. The compression yield behaviour of polymethyl methacrylate over a wide range of temperatures and strain-rates. J Mater Sci 1973; 8: 968-979.","DOI":"10.1007\/BF00756628"},{"key":"29","doi-asserted-by":"crossref","unstructured":"29) Bauwens-Crowet C, Bauwens JC, Hom\u00e8s G. Tensile yield-stress behavior of glassy polymers. J Polym Sci A Polym Phys 1969; 7: 735-742.","DOI":"10.1002\/pol.1969.160070411"},{"key":"30","doi-asserted-by":"crossref","unstructured":"30) Schmidt A, Kididane I, Schlenz MA, W\u00f6stmann B, Kolling S, Schrader P. Finite element simulation of fixed dental prostheses made from PMMA \u2014Part I: Experimental investigation under quasi-static loading and chewing velocities. Dent Mater J 2021; 40: 704-711.","DOI":"10.4012\/dmj.2020-230"},{"key":"31","unstructured":"31) Berlinger M, Schrader P, Kolling S. Analyses on the strain-rate dependent fracture behaviour of PMMA for stochastic simulations. 15. LS-Dyna Forum, Bamberg. 2018. Available at: https:\/\/www.dynamore.de\/de\/download\/papers\/2018-ls-dyna-forum\/papers-2018\/dienstag-16.-oktober\/crash-materials-failure."},{"key":"32","doi-asserted-by":"crossref","unstructured":"32) Ballarini R, Pisano G, Royer-Carfagni G. The lower bound for glass strength and its interpretation with generalized Weibull statistics for structural applications. J Eng Mech 2016; 142: 4016100.","DOI":"10.1061\/(ASCE)EM.1943-7889.0001151"},{"key":"33","doi-asserted-by":"crossref","unstructured":"33) Berlinger M. A Methodology to Model the Statistical Fracture Behavior of Acrylic Glasses for Stochastic Simulation. 1st ed. 2021. Wiesbaden: Springer Fachmedien Wiesbaden; Imprint Springer Vieweg; 2021. Springer eBook Collection; 59.","DOI":"10.1007\/978-3-658-34330-9_7"},{"key":"34","doi-asserted-by":"crossref","unstructured":"34) Berlinger M, Kolling S, Schneider J. A generalized Anderson-Darling test for the goodness-of-fit evaluation of the fracture strain distribution of acrylic glass. Glass Struct Eng 2021; 6: 195-208.","DOI":"10.1007\/s40940-021-00149-7"},{"key":"35","unstructured":"35) Lai C-D. Generalized Weibull Distributions. Berlin, Heidelberg: Springer Berlin Heidelberg; 2014."},{"key":"36","doi-asserted-by":"crossref","unstructured":"36) Makkonen L. Plotting positions in extreme value analysis. J Appl Meteor Climatol 2006; 45: 334-340.","DOI":"10.1175\/JAM2349.1"},{"key":"37","doi-asserted-by":"crossref","unstructured":"37) Anderson TW. On the distribution of the two-sample Cramer-von Mises criterion. Ann Math Statist 1962; 33: 1148-1159.","DOI":"10.1214\/aoms\/1177704477"},{"key":"38","doi-asserted-by":"crossref","unstructured":"38) Anderson TW, Darling DA. Asymptotic theory of certain \u201cGoodness of Fit\u201d criteria based on stochastic processes. Ann Math Statist 1952; 23: 193-212.","DOI":"10.1214\/aoms\/1177729437"},{"key":"39","doi-asserted-by":"crossref","unstructured":"39) Kv\u00e5lseth TO. Note on the R2 measure of goodness of fit for nonlinear models. Bull Psychon Soc 1983; 21: 79-80.","DOI":"10.3758\/BF03329960"},{"key":"40","doi-asserted-by":"crossref","unstructured":"40) Almohareb T, Alkatheeri MS, Vohra F, Alrahlah A. Influence of experimental staining on the color stability of indirect computer-aided design\/computer-aided manufacturing dental provisional materials. Eur J Dent 2018; 12: 269-274.","DOI":"10.4103\/ejd.ejd_1_18"},{"key":"41","doi-asserted-by":"crossref","unstructured":"41) Elagra MI, Rayyan MR, Alhomaidhi MM, Alanaziy AA, Alnefaie MO. Color stability and marginal integrity of interim crowns: An in vitro study. Eur J Dent 2017; 11: 330-334.","DOI":"10.4103\/ejd.ejd_66_17"},{"key":"42","doi-asserted-by":"crossref","unstructured":"42) Rayyan MM, Aboushelib M, Sayed NM, Ibrahim A, Jimbo R. Comparison of interim restorations fabricated by CAD\/CAM with those fabricated manually. J Prosthet Dent 2015; 114: 414-419.","DOI":"10.1016\/j.prosdent.2015.03.007"}],"container-title":["Dental Materials Journal"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.jstage.jst.go.jp\/article\/dmj\/42\/2\/42_2022-163\/_pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,4,1]],"date-time":"2023-04-01T05:10:12Z","timestamp":1680325812000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.jstage.jst.go.jp\/article\/dmj\/42\/2\/42_2022-163\/_article"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2023,3,25]]},"references-count":42,"journal-issue":{"issue":"2","published-print":{"date-parts":[[2023]]}},"URL":"https:\/\/doi.org\/10.4012\/dmj.2022-163","relation":{},"ISSN":["0287-4547","1881-1361"],"issn-type":[{"value":"0287-4547","type":"print"},{"value":"1881-1361","type":"electronic"}],"subject":[],"published":{"date-parts":[[2023,3,25]]},"article-number":"2022-163"}}