{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,8,18]],"date-time":"2026-08-18T05:26:14Z","timestamp":1787030774706,"version":"build-2736575974"},"reference-count":35,"publisher":"Japanese Society for Dental Materials and Devices","issue":"3","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Dent. Mater. J.","Dental Materials Journal"],"published-print":{"date-parts":[[2023,5,25]]},"DOI":"10.4012\/dmj.2022-188","type":"journal-article","created":{"date-parts":[[2023,1,27]],"date-time":"2023-01-27T17:11:44Z","timestamp":1674839504000},"page":"336-342","source":"Crossref","is-referenced-by-count":3,"title":["Retentive force of a conical crown with CAD\/CAM-fabricated PEEK and zirconia secondary crowns on titanium implant abutments"],"prefix":"10.4012","volume":"42","author":[{"given":"Abdullah","family":"KAMEL","sequence":"first","affiliation":[{"name":"Department of Prosthetic Dentistry, Faculty of Dentistry, Minia University"},{"name":"Advanced Prosthodontics, Division of Oral Health Sciences, Graduate School, Tokyo Medical and Dental University (TMDU)"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Toshiki","family":"YAMAZAKI","sequence":"additional","affiliation":[{"name":"Advanced Prosthodontics, Division of Oral Health Sciences, Graduate School, Tokyo Medical and Dental University (TMDU)"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Natsuko","family":"MURAKAMI","sequence":"additional","affiliation":[{"name":"Advanced Prosthodontics, Division of Oral Health Sciences, Graduate School, Tokyo Medical and Dental University (TMDU)"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Huaxin","family":"LYU","sequence":"additional","affiliation":[{"name":"Advanced Prosthodontics, Division of Oral Health Sciences, Graduate School, Tokyo Medical and Dental University (TMDU)"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Kohei","family":"KOMINE","sequence":"additional","affiliation":[{"name":"Advanced Prosthodontics, Division of Oral Health Sciences, Graduate School, Tokyo Medical and Dental University (TMDU)"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Amr","family":"BADR","sequence":"additional","affiliation":[{"name":"Department of Prosthetic Dentistry, Faculty of Dentistry, Minia University"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Gehan","family":"FEKRY","sequence":"additional","affiliation":[{"name":"Department of Prosthetic Dentistry, Faculty of Dentistry, Minia University"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Hidekazu","family":"TAKAHASHI","sequence":"additional","affiliation":[{"name":"Course of Oral Health Engineering, School of Oral Health Care Sciences, Faculty of Dentistry, Tokyo Medical and Dental University (TMDU)"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Noriyuki","family":"WAKABAYASHI","sequence":"additional","affiliation":[{"name":"Advanced Prosthodontics, Division of Oral Health Sciences, Graduate School, Tokyo Medical and Dental University (TMDU)"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"2427","reference":[{"key":"1","doi-asserted-by":"crossref","unstructured":"1) El-Anwar MI, El-Taftazany EA, Hamed HA, ElHay MAA. Influence of number of implants and attachment type on stress distribution in mandibular implant-retained overdentures: Finite element analysis. Open Access Maced J Med Sci 2017; 5: 244-249.","DOI":"10.3889\/oamjms.2017.047"},{"key":"2","unstructured":"2) Krennmair G, Seemann R, Fazekas A, Ewers R, Piehslinger E.Patient preference and satisfaction with implant-supported mandibular overdentures retained with ball or locator attachments: A crossover clinical trial. Int J Oral Maxillofac Implants 2012; 27: 1560-1568."},{"key":"3","doi-asserted-by":"crossref","unstructured":"3) Vogel R, Smith-Palmer J, Valentine W. Evaluating the health economic implications and cost-effectiveness of dental implants: A literature review. Int J Oral Maxillofac Implants 2013; 28: 343-356.","DOI":"10.11607\/jomi.2921"},{"key":"4","doi-asserted-by":"crossref","unstructured":"4) Hoffmann O, Beaumont C, Tatakis DN, Zafiropoulos G-G. Telescopic crowns as attachments for implant supported restorations: A case series. J Oral Implantol 2006; 32: 291-299.","DOI":"10.1563\/0-815.1"},{"key":"5","unstructured":"5) Koller B, Att W, Strub JR. Survival rates of teeth, implants, and double crown-retained removable dental prostheses: A systematic literature review. Int J Prosthodont 2011; 24: 109-117."},{"key":"6","doi-asserted-by":"crossref","unstructured":"6) Goodacre CJ, Bernal G, Rungcharassaeng K, Kan JY. Clinical complications with implants and implant prostheses. J Prosthet Dent 2003; 90: 121-132.","DOI":"10.1016\/S0022-3913(03)00212-9"},{"key":"7","doi-asserted-by":"crossref","unstructured":"7) Wagner C, Stock V, Merk S, Schmidlin PR, Roos M, Eichberger M, <i>et al.<\/i> Retention load of telescopic crowns with different taper angles between cobalt-chromium and polyetheretherketone made with three different manufacturing processes examined by pull-off test. J Prosthodont 2018; 27: 162-168.","DOI":"10.1111\/jopr.12482"},{"key":"8","unstructured":"8) Walton JN, MacEntee MI. A prospective study on the maintenance of implant prostheses in private practice. Int J Prosthodont 1997; 10: 453-458."},{"key":"9","unstructured":"9) Nakajima T, Torii K, Fujii T, Tanaka J, Tanaka M. Retentive force of telescopic Ce TZP\/A crowns in water. J Osaka Dent Univ 2019; 2019: 171-177."},{"key":"10","doi-asserted-by":"crossref","unstructured":"10) Schubert O, Reitmaier J, Schweiger J, Erdelt K, Guth JF. Retentive force of PEEK secondary crowns on zirconia primary crowns over time. Clin Oral Investig 2019; 23: 2331-2338.","DOI":"10.1007\/s00784-018-2657-x"},{"key":"11","doi-asserted-by":"crossref","unstructured":"11) Sakai Y, Takahashi H, Iwasaki N, Igarashi Y. Effects of surface roughness and tapered angle of cone crown telescopic system on retentive force. Dent Mater J 2011; 30: 635-641.","DOI":"10.4012\/dmj.2011-006"},{"key":"12","doi-asserted-by":"crossref","unstructured":"12) Shimakura M, Nagata T, Takeuchi M, Nemoto T. Retentive force of pure titanium konus telescope crowns fabricated using CAD\/CAD system. Dent Mater J 2008; 27: 211-215.","DOI":"10.4012\/dmj.27.211"},{"key":"13","doi-asserted-by":"crossref","unstructured":"13) Merk S, Wagner C, Stock V, Eichberger M, Schmidlin PR, Roos M, <i>et al.<\/i> Suitability of secondary PEEK telescopic crowns on zirconia primary crowns: The influence of fabrication method and taper. Materials (Basel) 2016; 9: 908.","DOI":"10.3390\/ma9110908"},{"key":"14","doi-asserted-by":"crossref","unstructured":"14) Sun J, Zhang FQ. The application of rapid prototyping in prosthodontics. J Prosthodont 2012; 21: 641-644.","DOI":"10.1111\/j.1532-849X.2012.00888.x"},{"key":"15","doi-asserted-by":"crossref","unstructured":"15) Groesser J, Sachs C, Hei\u00df P, Stadelmann M, Erdelt K, Beuer F.Retention forces of 14-unit zirconia telescopic prostheses with six double crowns made from zirconia \u2014An in vitro study. Clin Oral Investig 2014; 18: 1173-1179.","DOI":"10.1007\/s00784-013-1093-1"},{"key":"16","doi-asserted-by":"crossref","unstructured":"16) Yoshikawa Y, Torii K, Tanaka M. Influence of the number of insertions and removals of telescopic zirconia\/alumina crowns on retentive force and settling. Dent Mater J 2019; 38: 671-677.","DOI":"10.4012\/dmj.2018-260"},{"key":"17","doi-asserted-by":"crossref","unstructured":"17) Refai OM, Nawar NH, Lebshtien IT. Assessment of retention of CAD-CAM milled PEKK vs PEEK double crown-retained removable partial dentures: A randomized clinical trial. J Contemp Dent Pract 2021; 22: 1250-1256.","DOI":"10.5005\/jp-journals-10024-3233"},{"key":"18","doi-asserted-by":"crossref","unstructured":"18) Priester M, M\u00fcller WD, Beuer F, Schmidt F, Schwitalla AD. Performance of PEEK based telescopic crowns, a comparative study. Dent Mater 2021; 37: 1667-1675.","DOI":"10.1016\/j.dental.2021.08.020"},{"key":"19","doi-asserted-by":"crossref","unstructured":"19) Verma R, Joda T, Bragger U, Wittneben JG. A systematic review of the clinical performance of tooth-retained and implant-retained double crown prostheses with a follow-up of \u22653 years. J Prosthodont 2013; 22: 2-12.","DOI":"10.1111\/j.1532-849X.2012.00905.x"},{"key":"20","doi-asserted-by":"crossref","unstructured":"20) Nakagawa S, Torii K, Tanaka M. Effects of taper and space settings of telescopic Ce-TZP\/A crowns on retentive force and settling. Dent Mater J 2017; 36: 230-235.","DOI":"10.4012\/dmj.2016-258"},{"key":"21","unstructured":"21) Nakagawa S, Torii K, Tanaka J, Tanaka M. Retentive force of the cone crown telescope prosthesis using ceriastabilized zirconia\/alumina nanocomposite with a CAD\/CAM system. J Osaka Dent Univ 2017; 51: 55-62."},{"key":"22","doi-asserted-by":"crossref","unstructured":"22) Hao J, Murakami N, Yamazaki T, Iwasaki N, Yatabe M, Takahashi H, <i>et al.<\/i> Flexural and fatigue properties of polyester disk material for milled resin clasps. Dent Mater J 2021; 40: 1359-1364.","DOI":"10.4012\/dmj.2021-037"},{"key":"23","doi-asserted-by":"crossref","unstructured":"23) Schwindling FS, Stober T, Rustemeier R, Schmitter M, Rues S.Retention behavior of double-crown attachments with zirconia primary and secondary crowns. Dent Mater 2016; 32: 695-702.","DOI":"10.1016\/j.dental.2016.03.002"},{"key":"24","doi-asserted-by":"crossref","unstructured":"24) Haraldson T, Carlsson GE. Bite force and oral function in patients with osseointegrated oral implants. Scand J Dent Res 1977; 85: 200-208.","DOI":"10.1111\/j.1600-0722.1977.tb00554.x"},{"key":"25","doi-asserted-by":"crossref","unstructured":"25) Ohkawa S, Okane H, Nagasawa T, Tsuru H. Changes in retention of various telescope crown assemblies over long-term use. J Prosthet Dent 1990; 64: 153-158.","DOI":"10.1016\/0022-3913(90)90170-H"},{"key":"26","doi-asserted-by":"crossref","unstructured":"26) Bayer S, Zuziak W, Kraus D, Keilig L, Stark H, Enkling N. Conical crowns with electroplated gold copings: Retention force changes caused by wear and combined off-axial load. Clin Oral Implants Res 2011; 22: 323-329.","DOI":"10.1111\/j.1600-0501.2010.02003.x"},{"key":"27","doi-asserted-by":"crossref","unstructured":"27) Ohida M, Yoda K, Nomura N, Hanawa T, Igarashi Y. Evaluation of the static frictional coefficients of Co-Cr and gold alloys for cone crown telescope denture retainer applications. Dent Mater J 2010; 29: 706-712.","DOI":"10.4012\/dmj.2010-011"},{"key":"28","unstructured":"28) Korber KH. [Conical crowns \u2014A rational telescopic system]. ZWR 1983; 92: 38-43."},{"key":"29","doi-asserted-by":"crossref","unstructured":"29) Kanbara T, Yajima Y, Yoshinari M. Wear behavior of tetragonal zirconia polycrystal versus titanium and titanium alloy. Biomed Mater 2011; 6: 021001.","DOI":"10.1088\/1748-6041\/6\/2\/021001"},{"key":"30","doi-asserted-by":"crossref","unstructured":"30) Sampaio M, Buciumeanu M, Henriques B, Silva FS, Souza JC, Gomes JR. Tribocorrosion behavior of veneering biomedical PEEK to Ti6Al4V structures. J Mech Behav Biomed Mater 2016; 54: 123-130.","DOI":"10.1016\/j.jmbbm.2015.09.010"},{"key":"31","doi-asserted-by":"crossref","unstructured":"31) Nakamura M, Tanaka A, Tasaka A, Yoshinari M, Takemoto S, Yamashita S. Comparison of retentive forces between telescopic crowns made of poly(ether ether ketone) and type 4 gold alloy. Dent Mater J 2021; 40: 129-135.","DOI":"10.4012\/dmj.2019-298"},{"key":"32","doi-asserted-by":"crossref","unstructured":"32) Pigozzo MN, Mesquita MF, Henriques GE, Vaz LG. The service life of implant-retained overdenture attachment systems. J Prosthet Dent 2009; 102: 74-80.","DOI":"10.1016\/S0022-3913(09)60112-8"},{"key":"33","doi-asserted-by":"crossref","unstructured":"33) Aragoneses J, Valverde NL, Fernandez-Dominguez M, Mena-Alvarez J, Rodriguez C, Gil J, <i>et al<\/i>. Relevant aspects of titanium and zirconia dental implants for their fatigue and osseointegration behaviors. Materials (Basel, Switzerland) 2022; 15: 4036.","DOI":"10.3390\/ma15114036"},{"key":"34","doi-asserted-by":"crossref","unstructured":"34) Jo JY, Yang DS, Huh JB, Heo JC, Yun MJ, Jeong CM. Influence of abutment materials on the implant-abutment joint stability in internal conical connection type implant systems. J Adv Prosthodont 2014; 6: 491-497.","DOI":"10.4047\/jap.2014.6.6.491"},{"key":"35","unstructured":"35) Becker H. [The removal force of removable telescopic dentures]. Zahnarztl Prax 1982; 33: 153-156."}],"container-title":["Dental Materials Journal"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.jstage.jst.go.jp\/article\/dmj\/42\/3\/42_2022-188\/_pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2024,5,10]],"date-time":"2024-05-10T01:05:40Z","timestamp":1715303140000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.jstage.jst.go.jp\/article\/dmj\/42\/3\/42_2022-188\/_article"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2023,5,25]]},"references-count":35,"journal-issue":{"issue":"3","published-print":{"date-parts":[[2023]]}},"URL":"https:\/\/doi.org\/10.4012\/dmj.2022-188","relation":{},"ISSN":["0287-4547","1881-1361"],"issn-type":[{"value":"0287-4547","type":"print"},{"value":"1881-1361","type":"electronic"}],"subject":[],"published":{"date-parts":[[2023,5,25]]},"article-number":"2022-188"}}