{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,7,20]],"date-time":"2026-07-20T12:48:51Z","timestamp":1784551731708,"version":"3.55.0"},"reference-count":53,"publisher":"Japanese Society for Dental Materials and Devices","issue":"5","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Dent. Mater. J.","Dental Materials Journal"],"published-print":{"date-parts":[[2023,9,25]]},"DOI":"10.4012\/dmj.2023-051","type":"journal-article","created":{"date-parts":[[2023,8,22]],"date-time":"2023-08-22T22:27:49Z","timestamp":1692743269000},"page":"700-707","source":"Crossref","is-referenced-by-count":1,"title":["The long-term effect of sub-boiling water on dental unit waterlines and its ability to control cross-contamination in dentistry"],"prefix":"10.4012","volume":"42","author":[{"given":"Erick Silva","family":"DALLALANA","sequence":"first","affiliation":[{"name":"Human Exposome and Infectious Diseases Network (HEID), School of Nursing of Ribeir\u00e3o Preto, University of S\u00e3o Paulo"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Rachel Maciel","family":"MONTEIRO","sequence":"additional","affiliation":[{"name":"Human Exposome and Infectious Diseases Network (HEID), School of Nursing of Ribeir\u00e3o Preto, University of S\u00e3o Paulo"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Viviane de C\u00e1ssia","family":"OLIVEIRA","sequence":"additional","affiliation":[{"name":"Human Exposome and Infectious Diseases Network (HEID), School of Nursing of Ribeir\u00e3o Preto, University of S\u00e3o Paulo"},{"name":"Department of Dental Materials and Prostheses, School of Dentistry of Ribeir\u00e3o Preto, University of S\u00e3o Paulo"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Felipe Lazarini","family":"BIM","sequence":"additional","affiliation":[{"name":"Human Exposome and Infectious Diseases Network (HEID), School of Nursing of Ribeir\u00e3o Preto, University of S\u00e3o Paulo"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Lucas Lazarini","family":"BIM","sequence":"additional","affiliation":[{"name":"Human Exposome and Infectious Diseases Network (HEID), School of Nursing of Ribeir\u00e3o Preto, University of S\u00e3o Paulo"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Denise Tornavoi","family":"CASTRO","sequence":"additional","affiliation":[{"name":"Department of Biomaterials, School of Dentistry of Uberaba, University of Uberaba"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ana Paula","family":"MACEDO","sequence":"additional","affiliation":[{"name":"Department of Dental Materials and Prostheses, School of Dentistry of Ribeir\u00e3o Preto, University of S\u00e3o Paulo"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Evandro","family":"WATANABE","sequence":"additional","affiliation":[{"name":"Human Exposome and Infectious Diseases Network (HEID), School of Nursing of Ribeir\u00e3o Preto, University of S\u00e3o Paulo"},{"name":"Department of Restorative Dentistry, School of Dentistry of Ribeir\u00e3o Preto, University of S\u00e3o Paulo"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"2427","reference":[{"key":"1","doi-asserted-by":"crossref","unstructured":"1) Eshleman JR, Sarrett DC. How the development of the high-speed turbine handpiece changed the practice of dentistry. 1953. J Am Dent Assoc 2013; 144: 29S-32S.","DOI":"10.14219\/jada.archive.2013.0245"},{"key":"2","doi-asserted-by":"crossref","unstructured":"2) Blake GC. The incidence and control of bacterial infection in dental spray reservoirs. Br Dent J 2022; 233: 397-400.","DOI":"10.1038\/s41415-022-4972-5"},{"key":"3","unstructured":"3) World Health Organization. Guidelines for drinking-water quality: fourth edition incorporating the first addendum. Geneva: World Health Organization; 2017."},{"key":"4","doi-asserted-by":"crossref","unstructured":"4) American Dental Association (ADA). ADA Statement on dental unit waterlines. J Am Dent Assoc 1996; 127: 185-186.","DOI":"10.14219\/jada.archive.1996.0167"},{"key":"5","unstructured":"5) Monteiro RM, Marques DM, Domingues PCA, Oliveira VC, Macedo AP, Razaboni AM, <i>et al<\/i>. Evaluation of a protocol for reducing the microbial contamination of dental unit water. Acta Odontol Latinoam 2018; 31: 138-143."},{"key":"6","doi-asserted-by":"crossref","unstructured":"6) Zhang Y, Ping Y, Zhou R, Wang J, Zhang G. High throughput sequencing-based analysis of microbial diversity in dental unit waterlines supports the importance of providing safe water for clinical use. J Infect Public Health 2018; 11: 357-363.","DOI":"10.1016\/j.jiph.2017.09.017"},{"key":"7","doi-asserted-by":"crossref","unstructured":"7) Kadaifciler DG, Cotuk A. Microbial contamination of dental unit waterlines and effect on quality of indoor air. Environ Monit Assess 2014; 186: 3431-3444.","DOI":"10.1007\/s10661-014-3628-6"},{"key":"8","doi-asserted-by":"crossref","unstructured":"8) Del Pozo JL. Biofilm-related disease. Expert Rev Anti Infect Ther 2018; 16: 51-65.","DOI":"10.1080\/14787210.2018.1417036"},{"key":"9","doi-asserted-by":"crossref","unstructured":"9) Kragh KN, Hutchison JB, Melaugh G, Rodesney C, Roberts AEL, Irie Y, <i>et al<\/i>. Role of multicellular aggregates in biofilm formation. mBio 2016; 7: e00237.","DOI":"10.1128\/mBio.00237-16"},{"key":"10","doi-asserted-by":"crossref","unstructured":"10) Maci\u00e0 MD, Rojo-Molinero E, Oliver A. Antimicrobial susceptibility testing in biofilm-growing bacteria. Clin Microbiol Infect 2014; 20: 981-990.","DOI":"10.1111\/1469-0691.12651"},{"key":"11","unstructured":"11) Lamba NMK, Woodhouse KA, Cooper SL. Polyurethanes in Biomedical Applications. 1st ed. Boca Raton: CRC Press, 1998."},{"key":"12","doi-asserted-by":"crossref","unstructured":"12) Bhagwat G, O\u2019Connor W, Grainge I, Palanisami T. Understanding the fundamental basis for biofilm formation on plastic surfaces: Role of conditioning films. Front Microbiol 2021; 12: 687118.","DOI":"10.3389\/fmicb.2021.687118"},{"key":"13","doi-asserted-by":"crossref","unstructured":"13) Bayani M, Raisolvaezin K, Almasi-Hashiani A, Mirhoseini SH. Bacterial biofilm prevalence in dental unit waterlines: A systematic review and meta-analysis. BMC Oral Health 2023; 23: 158.","DOI":"10.1186\/s12903-023-02885-4"},{"key":"14","doi-asserted-by":"crossref","unstructured":"14) Bansal R, Puttaiah R, Harris R, Reddy A. Evaluation of two methods in controlling dental treatment water contamination. J Contemp Dent Pract 2011; 12: 73-83.","DOI":"10.5005\/jp-journals-10024-1013"},{"key":"15","doi-asserted-by":"crossref","unstructured":"15) Shajahan IF, Kandaswamy D, Lakshminarayanan L, Selvarajan R. Substantivity of hypochlorous acid-based disinfectant against biofilm formation in the dental unit waterlines. J Conserv Dent 2017; 20: 2-5.","DOI":"10.4103\/0972-0707.209076"},{"key":"16","unstructured":"16) Hikal W, Zaki B, Sabry H. Evaluation of ozone application in dental unit water lines contaminated with pathogenic <i>Acanthamoeba<\/i>. Iran J Parasitol 2015; 10: 410-419."},{"key":"17","doi-asserted-by":"crossref","unstructured":"17) Fujita M, Mashima I, Nakazawa F. Monitoring the decontamination efficacy of the novel Poseidon-S disinfectant system in dental unit water lines. J Microbiol Immunol Infect 2017; 50: 270-276.","DOI":"10.1016\/j.jmii.2015.05.006"},{"key":"18","doi-asserted-by":"crossref","unstructured":"18) Ampornaramveth RS, Akeatichod N, Lertnukkhid J, Songsang N. Application of D-amino acids as biofilm dispersing agent in dental unit waterlines. Int J Dent 2018; 2018: 9413925.","DOI":"10.1155\/2018\/9413925"},{"key":"19","doi-asserted-by":"crossref","unstructured":"19) Ditommaso S, Giacomuzzi M, Ricciardi E, Garbuio R, Zotti CM. The role of chemical products at low doses in preventing the proliferation of bacteria in dental unit waterlines: The ICX<sup>\u00ae<\/sup> experience. J Water Health 2018; 16: 150-158.","DOI":"10.2166\/wh.2017.035"},{"key":"20","doi-asserted-by":"crossref","unstructured":"20) Lizzadro J, Mazzotta M, Girolamini L, Dormi A, Pellati T, Cristino S. comparison between two types of dental unit waterlines: How evaluation of microbiological contamination can support risk containment. Int J Environ Res Public Health 2019; 16: 328.","DOI":"10.3390\/ijerph16030328"},{"key":"21","doi-asserted-by":"crossref","unstructured":"21) Castro ACM, Monteiro RM, Domingues PCA, Machado MB, Razaboni AM, Watanabe E. Control of bacterial contamination of dental unit water using sodium hypochlorite. Revista Preven\u00e7\u00e3o de Infec\u00e7\u00e3o e Sa\u00fade 2019; 5: 8502.","DOI":"10.26694\/repis.v5i0.8502"},{"key":"22","doi-asserted-by":"crossref","unstructured":"22) Boyle MA, O\u2019Donnell MJ, Russell RJ, Coleman DC. Lack of cytotoxicity by Trustwater Ecasol\u2122 used to maintain good quality dental unit waterline output water in keratinocyte monolayer and reconstituted human oral epithelial tissue models. J Dent 2010; 38: 930-940.","DOI":"10.1016\/j.jdent.2010.08.005"},{"key":"23","doi-asserted-by":"crossref","unstructured":"23) Lal S, Singhrao SK, Achilles-Day UE, Morton LH, Pearce M, Crean S. Risk assessment for the spread of <i>Serratia marcescens<\/i> within dental-unit waterline systems using <i>Vermamoeba vermiformis<\/i>. Curr Microbiol 2015; 71: 434-442.","DOI":"10.1007\/s00284-015-0872-0"},{"key":"24","doi-asserted-by":"crossref","unstructured":"24) Currier RW, Widness JA. A brief history of milk hygiene and its impact on infant mortality from 1875 to 1925 and implications for today: A review. J Food Prot 2018; 81: 1713-1722.","DOI":"10.4315\/0362-028X.JFP-18-186"},{"key":"25","doi-asserted-by":"crossref","unstructured":"25) Winthrop KL, Homestead N. High level disinfection of a home care device; to boil or not to boil? J Hosp Infect 2012; 80: 262-264.","DOI":"10.1016\/j.jhin.2011.12.018"},{"key":"26","unstructured":"26) Madigan MT, Martinko JM, Bender KS, Buckley DH, Stahl DA. Microbiologia de Brock. 14th ed. Porto Alegre: Artmed; 2016. p.1006."},{"key":"27","doi-asserted-by":"crossref","unstructured":"27) Spinks AT, Dunstan RH, Harrison T, Coombes P, Kuczera G. Thermal inactivation of water-borne pathogenic and indicator bacteria at sub-boiling temperatures. Water Res 2006; 40: 1326-1332.","DOI":"10.1016\/j.watres.2006.01.032"},{"key":"28","unstructured":"28) World Health Organization (WHO). Boil Water. Technical Brief. WHO\/FWC\/WSH\/15.02. Geneva: World Health Organization; 2015."},{"key":"29","doi-asserted-by":"crossref","unstructured":"29) Gandolfi MG, Zamparini F, Spinelli A, Risi A, Prati C. Musculoskeletal disorders among Italian dentists and dental hygienists. Int J Environ Res Public Health 2021; 18: 2705.","DOI":"10.3390\/ijerph18052705"},{"key":"30","doi-asserted-by":"crossref","unstructured":"30) Arruda CNF, Sorgini DB, Oliveira VC, Macedo AP, Lovato CHS, Paranhos HFO. Effects of denture cleansers on heat-polymerized acrylic resin: A five-year-simulated period of use. Braz Dent J 2015; 26: 404-408.","DOI":"10.1590\/0103-6440201300120"},{"key":"31","doi-asserted-by":"crossref","unstructured":"31) Pinheiro JB, Reis AC, Pisani MX, Leite VMF, Souza RF, Paranhos HFO, <i>et al<\/i>. Microstructural characterization and evaluation of the properties of polymeric materials for maxillofacial prosthetics. J Med Eng Technol 2014; 38: 67-75.","DOI":"10.3109\/03091902.2013.864715"},{"key":"32","doi-asserted-by":"crossref","unstructured":"32) Monteiro RM, Oliveira VC, Galo R, Andrade D, Razaboni AM, Watanabe E. Protocol with non-toxic chemicals to control biofilm in dental unit waterlines: Physical, chemical, mechanical and biological perspective. Biofouling 2022; 38: 628-642.","DOI":"10.1080\/08927014.2022.2106857"},{"key":"33","unstructured":"33) Pantanella F, Schippa S, Solimini A, Rosa L, Bettucci A, Berlutti F. Efficacy of acoustic waves in preventing <i>Streptococcus mutans<\/i> adhesion on dental unit water line. Ann Ig 2019; 31: 109-116."},{"key":"34","doi-asserted-by":"crossref","unstructured":"34) van der Kooij D, Brouwer-Hanzens AJ, Veenendaal HR, Wullings BA. Multiplication of <i>Legionella pneumophila <\/i>sequence types 1, 47, and 62 in buffered yeast extract broth and biofilms exposed to flowing tap water at temperatures of 38\u00b0C to 42\u00b0C. Appl Environ Microbiol 2016; 82: 6691-6700.","DOI":"10.1128\/AEM.01107-16"},{"key":"35","doi-asserted-by":"crossref","unstructured":"35) Stevenson JS, Kusy RP. Structural degradation of polyurethane-based elastomeric modules. J Mater Sci Mater Med 1995; 6: 377-384.","DOI":"10.1007\/BF00120277"},{"key":"36","doi-asserted-by":"crossref","unstructured":"36) Bovas BC, Karunamoorthy L, Chuan FB. Effect of surface roughness and process parameters on mechanical properties of fabricated medical catheters. Mater Res Express 2019; 6: 125420.","DOI":"10.1088\/2053-1591\/ab6652"},{"key":"37","doi-asserted-by":"crossref","unstructured":"37) Zheng S, Bawazir M, Dhall A, Kim HE, He L, Heo J, <i>et al<\/i>. Implication of surface properties, bacterial motility, and hydrodynamic conditions on bacterial surface sensing and their initial adhesion. Front Bioeng Biotechnol 2021; 9: 643722.","DOI":"10.3389\/fbioe.2021.643722"},{"key":"38","doi-asserted-by":"crossref","unstructured":"38) Schmidt J, Wei R, Oeser T, Dedavid E Silva LA, Breite D, Schulze A, <i>et al<\/i>. Degradation of polyester polyurethane by bacterial polyester hydrolases. Polymers (Basel) 2017; 9: 65.","DOI":"10.3390\/polym9020065"},{"key":"39","unstructured":"39) Castex J, Houssin D. Water in healthcare facilities. France: Minist\u00e8re de la Sant\u00e9 et des Solidarit\u00e9s; 2005."},{"key":"40","unstructured":"40) Department of Health, Estates &amp; Facilities and Government of Great Britain. Water systems: Health Technical Memorandum 04-01: Addendum. <i>Pseudomonas aeruginosa<\/i> \u2013 Advice for augmented care units. Department of Health: London; 2013. https:\/\/assets.publishing.service.gov.uk\/government\/uploads\/system\/uploads\/attachment_data\/file\/140105\/Health_Technical_Memorandum_04-01_Addendum.pdf."},{"key":"41","doi-asserted-by":"crossref","unstructured":"41) Al-Hiyasat AS, Ma\u2019ayeh SY, Hindiyeh MY, Khader YS. The presence of <i>Pseudomonas aeruginosa<\/i> in the dental unit waterline systems of teaching clinics. Int J Dent Hyg 2007; 5: 36-44.","DOI":"10.1111\/j.1601-5037.2007.00221.x"},{"key":"42","doi-asserted-by":"crossref","unstructured":"42) Ricci ML, Fontana S, Pinci F, Fiumana E, Pedna MF, Farolfi P, <i>et al<\/i>. Pneumonia associated with a dental unit waterline. Lancet 2012; 379: 684.","DOI":"10.1016\/S0140-6736(12)60074-9"},{"key":"43","doi-asserted-by":"crossref","unstructured":"43) Mena KD, Gerba CP. Risk assessment of <i>Pseudomonas aeruginosa<\/i> in water. Rev Environ Contam Toxicol 2009; 201: 71-115.","DOI":"10.1007\/978-1-4419-0032-6_3"},{"key":"44","doi-asserted-by":"crossref","unstructured":"44) Martin MV. The significance of the bacterial contamination of dental unit water systems. Br Dent J 1987; 163: 152-154.","DOI":"10.1038\/sj.bdj.4806220"},{"key":"45","doi-asserted-by":"crossref","unstructured":"45) Souza LCD, Lopes FF, Bastos EG, Alves CMC. Oral infection by <i>Pseudomonas aeruginosa<\/i> in patient with chronic kidney disease \u2014A case report. J Bras Nefrol 2018; 40: 82-85.","DOI":"10.1590\/1678-4685-jbn-3812"},{"key":"46","doi-asserted-by":"crossref","unstructured":"46) Pereira RS, Bonardi JP, Ferreira A, Latini GL. An unusual case of dental infection by <i>Pseudomonas aeruginosa<\/i> causing a brain abscess: Case report. Aust Dent J 2017; 62: 523-527.","DOI":"10.1111\/adj.12539"},{"key":"47","doi-asserted-by":"crossref","unstructured":"47) Magana M, Sereti C, Ioannidis A, Mitchell CA, Ball AR, Magiorkinis E, <i>et al.<\/i> Options and limitations in clinical investigation of bacterial biofilms. Clin Microbiol Rev 2018; 31: e00084-00016.","DOI":"10.1128\/CMR.00084-16"},{"key":"48","doi-asserted-by":"crossref","unstructured":"48) Azeredo J, Azevedo NF, Briandet R, Cerca N, Coenye T, Costa AR, <i>et al.<\/i> Critical review on biofilm methods. Crit Rev Microbiol 2017; 43: 313-351.","DOI":"10.1080\/1040841X.2016.1208146"},{"key":"49","doi-asserted-by":"crossref","unstructured":"49) Farhat M, Trouilh\u00e9 MC, Briand E, Moletta-Denat M, Robine E, Fr\u00e8re J. Development of a pilot-scale 1 for <i>Legionella<\/i> elimination in biofilm in hot water network: Heat shock treatment evaluation. J Appl Microbiol 2010; 108: 1073-1082.","DOI":"10.1111\/j.1365-2672.2009.04541.x"},{"key":"50","unstructured":"50) Kisk\u00f3 G, Szab\u00f3-Szab\u00f3 O. Biofilm removal of <i>Pseudomonas<\/i> strains using hot water sanitation. Acta Univ Sapientiae, Alimentaria 2011; 4: 69-79."},{"key":"51","unstructured":"51) Centers for Disease Control and Prevention (CDC). Recommended infection-control practices for dentistry. MMWR 1993; 28: 1-12."},{"key":"52","doi-asserted-by":"crossref","unstructured":"52) Cobb CM, Martel CR, McKnight SA 3rd, Pasley-Mowry C, Ferguson BL, Williams K. How does time-dependent dental unit waterline flushing affect planktonic bacteria levels? J Dent Educ 2002; 66: 549-555.","DOI":"10.1002\/j.0022-0337.2002.66.4.tb03534.x"},{"key":"53","doi-asserted-by":"crossref","unstructured":"53) Brown F, Diller KR. Calculating the optimum temperature for serving hot beverages. Burns 2008; 34: 648-654.","DOI":"10.1016\/j.burns.2007.09.012"}],"container-title":["Dental Materials Journal"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.jstage.jst.go.jp\/article\/dmj\/42\/5\/42_2023-051\/_pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2024,5,13]],"date-time":"2024-05-13T04:58:45Z","timestamp":1715576325000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.jstage.jst.go.jp\/article\/dmj\/42\/5\/42_2023-051\/_article"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2023,9,25]]},"references-count":53,"journal-issue":{"issue":"5","published-print":{"date-parts":[[2023]]}},"URL":"https:\/\/doi.org\/10.4012\/dmj.2023-051","relation":{},"ISSN":["0287-4547","1881-1361"],"issn-type":[{"value":"0287-4547","type":"print"},{"value":"1881-1361","type":"electronic"}],"subject":[],"published":{"date-parts":[[2023,9,25]]},"article-number":"2023-051"}}