{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,6,10]],"date-time":"2026-06-10T15:25:48Z","timestamp":1781105148612,"version":"3.54.1"},"reference-count":46,"publisher":"IGI Global Scientific Publishing","issue":"3","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":[],"published-print":{"date-parts":[[2017,7,1]]},"abstract":"<p>Background: Hospitals need to accurately manage mobile devices (e.g., intravenous pumps) associated to their patients and health providers to ensure patient safety. Some hospitals have already invested substantially in real-time location system (RTLS) technology, a specific type of Internet of Things (IoT) application for indoor positioning, to manage mobile clinical devices. Objective: This paper investigates the reuse of RTLS systems to monitor patients and their assigned devices and to manage their connectivity automatically, in real time. Method: A system called Real-time Patient-Device Association and Disassociation (RPDAD) is designed, implemented, and tested in a hospital room and in a university laboratory. Results: RPDAD helps manage patient-device associations through a tablet application, with accurate suggestions for closest devices and automated detection of unexpected disassociations, resulting in real-time alerts. Conclusion: RPDAD offers a usable means of managing associations that does not depend on bar-coding technologies. It also helps amortize investments in RTLS.<\/p>","DOI":"10.4018\/ijhisi.2017070103","type":"journal-article","created":{"date-parts":[[2017,5,31]],"date-time":"2017-05-31T13:18:13Z","timestamp":1496236693000},"page":"37-61","source":"Crossref","is-referenced-by-count":1,"title":["Real-Time, Location-Based Patient-Device Association Management"],"prefix":"10.4018","volume":"12","author":[{"given":"Raoufeh","family":"Rezaee","sequence":"first","affiliation":[{"name":"University of Ottawa, Ontario, Canada"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Malak","family":"Baslyman","sequence":"additional","affiliation":[{"name":"University of Ottawa, Ontario, Canada"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Daniel","family":"Amyot","sequence":"additional","affiliation":[{"name":"University of Ottawa, Ontario, Canada"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Alain","family":"Mouttham","sequence":"additional","affiliation":[{"name":"Montfort Hospital, Ontario, Canada"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Rana","family":"Chreyh","sequence":"additional","affiliation":[{"name":"Canadian Blood Services, Ontario, Canada"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Glen","family":"Geiger","sequence":"additional","affiliation":[{"name":"The Ottawa Hospital, Ontario, Canada"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"2432","reference":[{"key":"IJHISI.2017070103-0","doi-asserted-by":"crossref","unstructured":"AiRISTA Flow. (2016) Hardware. Retrieved December 31, 2016, from https:\/\/www.airistaflow.com\/hardware\/","DOI":"10.1017\/CBO9781316135990.003"},{"key":"IJHISI.2017070103-1","doi-asserted-by":"publisher","DOI":"10.4304\/jsw.6.5.747-768"},{"key":"IJHISI.2017070103-2","doi-asserted-by":"publisher","DOI":"10.1109\/ICSE.1996.493439"},{"key":"IJHISI.2017070103-3","doi-asserted-by":"publisher","DOI":"10.1109\/TSE.1986.6312975"},{"key":"IJHISI.2017070103-4","doi-asserted-by":"crossref","unstructured":"Baskerville, R., Pries-Heje, J., & Venable, J. (2009) Soft Design Science Methodology. Proceedings of the 4th International Conference on Design Science Research in Information Systems and Technology (DESRIST). ACM.","DOI":"10.1145\/1555619.1555631"},{"key":"IJHISI.2017070103-5","doi-asserted-by":"publisher","DOI":"10.1016\/j.procs.2014.08.039"},{"key":"IJHISI.2017070103-6","doi-asserted-by":"publisher","DOI":"10.1007\/s00779-015-0855-y"},{"issue":"3-4","key":"IJHISI.2017070103-7","doi-asserted-by":"crossref","first-page":"137","DOI":"10.3233\/RFT-130056","article-title":"RFID-enabled Real-Time Location System (RTLS) to improve hospital\u2019s operations management: An up-to-date typology.","volume":"5","author":"Y.Bendavid","year":"2013","journal-title":"Journal of RF Technologies: Research and Applications"},{"key":"IJHISI.2017070103-8","doi-asserted-by":"publisher","DOI":"10.1002\/9780470665251"},{"key":"IJHISI.2017070103-9","unstructured":"Bougueng Tchemeube, R., Amyot, D., & Mouttham, A. (2013) Location-Aware Business Process Management for Real-time Monitoring of a Cardiac Care Process. Proceedings of the 23rd Int. Conf. Center for Advanced Studies on Collaborative Research (CASCON\u201913) (pp. 230\u2012244). ACM."},{"key":"IJHISI.2017070103-10","doi-asserted-by":"crossref","unstructured":"Byunggil, L., & Howon, K. (2007) Privacy Management for Medical Service Application Using Mobile Phone Collaborated with RFID Reader. Proceedings of the 3rd Int. Conf. on Signal-Image Technologies and Internet-Based System (SITIS\u201907) (pp. 1053\u20121057). doi:10.1109\/SITIS.2007.150","DOI":"10.1109\/SITIS.2007.150"},{"key":"IJHISI.2017070103-11","doi-asserted-by":"publisher","DOI":"10.1109\/IEMBS.2006.259579"},{"key":"IJHISI.2017070103-12","doi-asserted-by":"publisher","DOI":"10.1145\/1324892.1324951"},{"key":"IJHISI.2017070103-13","unstructured":"ECRI Institute, ISMP. (2008) Medication Errors Occurring with the Use of Bar-Code Administration Technology. ECRI Institute, 5(4), 122\u20131266."},{"key":"IJHISI.2017070103-14","year":"2010","journal-title":"Professional Services"},{"key":"IJHISI.2017070103-15","unstructured":"Ekahau Inc. (2014) The Ekahau Real-Time Location System. Retrieved December 31, 2016 from http:\/\/bit.ly\/2its93H"},{"key":"IJHISI.2017070103-16","doi-asserted-by":"crossref","unstructured":"Fisher, J.A., & Monahan, T. (2012) Evaluation of real-time location systems in their hospital contexts. International Journal of Medical Informatics, October, 705\u201312. doi:10.1016\/j.ijmedinf.2012.07.001","DOI":"10.1016\/j.ijmedinf.2012.07.001"},{"key":"IJHISI.2017070103-17","doi-asserted-by":"crossref","unstructured":"Frisch, P. H., Miodownik, S., Booth, P., Carragee, P., & Dowling, M. (2009) Patient Centric Identification and Association. Engineering in Medicine and Biology Society, 2009. EMBC 2009. Annual International Conference of the IEEE (pp. 1722\u20131726). doi:10.1109\/IEMBS.2009.5333558","DOI":"10.1109\/IEMBS.2009.5333558"},{"key":"IJHISI.2017070103-18","doi-asserted-by":"crossref","unstructured":"Frisch, P. H., & Pappas, H. H. (2011) Impact of Smart Room Designs on Workflow, Patient Care & Safety. Proceedings of the 2nd Annual AMA-IEEE Medical Technology Conference. IEEE.","DOI":"10.1109\/MPUL.2011.942057"},{"key":"IJHISI.2017070103-19","doi-asserted-by":"crossref","unstructured":"Gao, T., Greenspan, D., Welsh, M., Juang, R., & Alm, A. (2006) Vital Signs Monitoring and Patient Tracking Over a Wireless Network. Proceedings of the 27th Annual Conference on Engineering in Medicine and Biology (pp. 102\u2013105). doi:10.1109\/IEMBS.2005.1616352","DOI":"10.1109\/IEMBS.2005.1616352"},{"key":"IJHISI.2017070103-20","doi-asserted-by":"publisher","DOI":"10.1109\/NEBC.2006.1629830"},{"key":"IJHISI.2017070103-21","unstructured":"Hawkins, R. E., & Burke, M. D. (1989) Person Monitoring System. U.S. patent 4814751 A. Retrieved April 13, 2016 from http:\/\/www.google.com\/patents\/US4814751"},{"key":"IJHISI.2017070103-22","doi-asserted-by":"publisher","DOI":"10.1109\/SIEDS.2011.5876843"},{"key":"IJHISI.2017070103-23","unstructured":"Herbst, D., Cannon, P., Higgins, J., & Gannon, M. (2010) Patient to device association. U.S. patent 20100169120 A1. Retrieved April 13, 2016, from http:\/\/www.google.com\/patents\/US20100169120"},{"issue":"7","key":"IJHISI.2017070103-24","first-page":"64","article-title":"Out of control little-used clinical assets are draining healthcare budgets.","volume":"66","author":"R.Horblyuk","year":"2012","journal-title":"Healthcare Financial Management"},{"key":"IJHISI.2017070103-25","doi-asserted-by":"publisher","DOI":"10.1007\/s10916-016-0479-4"},{"key":"IJHISI.2017070103-26","unstructured":"ISO\/IEC 14443 (2008) Identification cards \u2013 Contactless integrated circuit cards \u2013 Proximity cards. ISO Standard 2008 (revised 2013)."},{"key":"IJHISI.2017070103-27","unstructured":"ISO\/IEC 24730-1 (2006). Information technology \u2013 Real-time locating systems (RTLS) \u2013 Part 1: Application programming interface (API). ISO Standard (revised 2014)."},{"key":"IJHISI.2017070103-28","doi-asserted-by":"publisher","DOI":"10.1197\/jamia.M2616"},{"key":"IJHISI.2017070103-29","doi-asserted-by":"publisher","DOI":"10.1109\/NCCA.2012.30"},{"key":"IJHISI.2017070103-30","doi-asserted-by":"publisher","DOI":"10.1109\/TITB.2006.888701"},{"key":"IJHISI.2017070103-31","unstructured":"MarketsAndMarkets.com. (2016). RTLS Market for Healthcare by Facility Type (Hospitals and Health Facilities and Senior Living Facilities), Offering (Hardware, Software, and Services), Technology (RFID, Wi-Fi, BLE, and UWB), Application, and Geography - Global Forecast to 2022 (Report SE 2568). Retrieved December 21, 2016, from http:\/\/www.marketsandmarkets.com\/Market-Reports\/rtls-healthcare-market-19089515.html"},{"key":"IJHISI.2017070103-32","doi-asserted-by":"publisher","DOI":"10.1016\/j.jnca.2010.04.011"},{"key":"IJHISI.2017070103-33","unstructured":"Neff, R. A. (2013) Automatic patient and device recognition and association system. U.S. patent 8565500 B2. Retrieved April 13, 2016 from http:\/\/www.google.com\/patents\/US8565500"},{"key":"IJHISI.2017070103-34","doi-asserted-by":"publisher","DOI":"10.1016\/j.compbiomed.2010.03.007"},{"key":"IJHISI.2017070103-35","doi-asserted-by":"publisher","DOI":"10.1145\/336512.336586"},{"key":"IJHISI.2017070103-36","doi-asserted-by":"crossref","unstructured":"Pettus, D. C. (2004) Mobile Medical Device Connectivity: Real World Solutions. Proceedings of the 26th Annual International Conference of the IEEE EMBS (pp. 3450\u20123451). doi:10.1109\/IEMBS.2004.1403968","DOI":"10.1109\/IEMBS.2004.1403968"},{"key":"IJHISI.2017070103-37","doi-asserted-by":"publisher","DOI":"10.1109\/COMSNETS.2013.6465599"},{"key":"IJHISI.2017070103-38","doi-asserted-by":"publisher","DOI":"10.1109\/CARE.2013.6733768"},{"key":"IJHISI.2017070103-39","doi-asserted-by":"publisher","DOI":"10.1109\/ATNAC.2010.5679557"},{"key":"IJHISI.2017070103-40","unstructured":"Rezaee, R. (2014, November) Patient-Device Association and Disassociation with a Real-Time Location System [M.Sc. thesis]. University of Ottawa, Ottawa, Canada. Retrieved January 3, 2017 from http:\/\/hdl.handle.net\/10393\/31863"},{"key":"IJHISI.2017070103-41","doi-asserted-by":"crossref","unstructured":"Rezaee, R., Baslyman, M., Amyot, D., Mouttham, A., Chreyh, R., & Geiger, G. (2014) Location-Based Patient-Device Association and Disassociation. Proceedings of the4th Int. Conference on Current and Future Trends of Information and Communication Technologies in Healthcare (ICTH-2014) (pp. 282\u2013286).","DOI":"10.1016\/j.procs.2014.08.042"},{"key":"IJHISI.2017070103-42","doi-asserted-by":"publisher","DOI":"10.1109\/TITB.2012.2204896"},{"key":"IJHISI.2017070103-43","doi-asserted-by":"crossref","unstructured":"Sundaresan, S., Doss, R., & Zhou, W. (2015) RFID in Healthcare \u2013 Current Trends and the Future. In Mobile Health: A Technology Road Map, SIB (Vol. 5, pp. 839\u2013870), Springer.","DOI":"10.1007\/978-3-319-12817-7_36"},{"key":"IJHISI.2017070103-44","doi-asserted-by":"publisher","DOI":"10.1109\/ICCCyb.2013.6617624"},{"key":"IJHISI.2017070103-45","doi-asserted-by":"publisher","DOI":"10.1016\/j.jnca.2010.04.020"}],"container-title":["International Journal of Healthcare Information Systems and Informatics"],"original-title":[],"language":"ng","link":[{"URL":"https:\/\/www.igi-global.com\/viewtitle.aspx?TitleId=182481","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,8,23]],"date-time":"2023-08-23T16:57:39Z","timestamp":1692809859000},"score":1,"resource":{"primary":{"URL":"https:\/\/services.igi-global.com\/resolvedoi\/resolve.aspx?doi=10.4018\/IJHISI.2017070103"}},"subtitle":["Design and Proof of Concept"],"short-title":[],"issued":{"date-parts":[[2017,7,1]]},"references-count":46,"journal-issue":{"issue":"3","published-print":{"date-parts":[[2017,7]]}},"URL":"https:\/\/doi.org\/10.4018\/ijhisi.2017070103","relation":{},"ISSN":["1555-3396","1555-340X"],"issn-type":[{"value":"1555-3396","type":"print"},{"value":"1555-340X","type":"electronic"}],"subject":[],"published":{"date-parts":[[2017,7,1]]}}}