{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2024,1,13]],"date-time":"2024-01-13T00:00:45Z","timestamp":1705104045632},"reference-count":36,"publisher":"IGI Global","issue":"1","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":[],"published-print":{"date-parts":[[2013,1,1]]},"abstract":"<p>Implantable Medical Devices (IMDs) with wireless telemetry functionalities in the radio-frequency (RF) range are recently attracting significant scientific interest for medical prevention, diagnosis, and therapy. One of the most crucial challenges for IMDs is the design of the integrated implantable antenna which enables bidirectional wireless communication between the IMD and exterior monitoring\/control equipment. In this paper, a parametric model of a miniature implantable antenna is initially proposed, which can be adjusted to suit any antenna design and implantation scenario requirements in hand. Dependence of the resonance, radiation, and safety performance of implantable antennas upon (a) operation frequency, (b) tissue anatomy and dielectric properties, and (c) implantation site is further studied. Simulations are carried out: (a) at 402, 433, 868 and 915 MHz considering a 13-tissue anatomical head model, (b) at 402 MHz considering five head models (3- and 5-layer spherical, 6-, 10- and 13-tissue anatomical) and seven dielectric parameter scenarios (variations \u00b120% in the reference permittivity and conductivity values), and (c) at 402 MHz considering 3-layer canonical models of the human head, arm, and trunk. The study provides valuable insight into the design of implantable antennas. Finite Element and Finite Difference Time Domain numerical solvers are used.<\/p>","DOI":"10.4018\/ijmstr.2013010102","type":"journal-article","created":{"date-parts":[[2013,7,10]],"date-time":"2013-07-10T14:01:53Z","timestamp":1373464913000},"page":"16-33","source":"Crossref","is-referenced-by-count":6,"title":["Design of Implantable Antennas for Medical Telemetry"],"prefix":"10.4018","volume":"1","author":[{"given":"Asimina","family":"Kiourti","sequence":"first","affiliation":[{"name":"School of Electrical and Computer Engineering,National Technical University of Athens, Athens, Greece"}]},{"given":"Konstantina S.","family":"Nikita","sequence":"additional","affiliation":[{"name":"School of Electrical and Computer Engineering,National Technical University of Athens, Athens, Greece"}]}],"member":"2432","reference":[{"key":"ijmstr.2013010102-0","doi-asserted-by":"publisher","DOI":"10.1109\/22.641720"},{"key":"ijmstr.2013010102-1","doi-asserted-by":"publisher","DOI":"10.1155\/ASP.2005.3069"},{"key":"ijmstr.2013010102-2","doi-asserted-by":"publisher","DOI":"10.1109\/TBME.2003.809474"},{"key":"ijmstr.2013010102-3","doi-asserted-by":"publisher","DOI":"10.1088\/0031-9155\/53\/6\/001"},{"key":"ijmstr.2013010102-4","unstructured":"European Radiocommunications Committee. (ERC). (1997). European Radiocommunications Committee recommendation 70-03 relating to the use of short range devices. In Proceedings of the European Conference of Postal and Telecommications Administration (EPT) (CEPT\/ERC 70-03), Tromso, Norway."},{"issue":"240","key":"ijmstr.2013010102-5","first-page":"69926","article-title":"Medical implant communications service (MICS) federal register.","volume":"64","year":"1999","journal-title":"Rules Regulations"},{"key":"ijmstr.2013010102-6","unstructured":"Finite Difference Time Domain, X. (XFDTD). (2005). Electromagnetic solver based on the finite difference time domain method. State College, PA: Remcom."},{"key":"ijmstr.2013010102-7","doi-asserted-by":"publisher","DOI":"10.1088\/0031-9155\/41\/11\/003"},{"key":"ijmstr.2013010102-8","doi-asserted-by":"publisher","DOI":"10.1109\/TMTT.2004.832007"},{"key":"ijmstr.2013010102-9","doi-asserted-by":"publisher","DOI":"10.1016\/S0165-0270(99)00076-X"},{"key":"ijmstr.2013010102-10","unstructured":"High Frequency Structure Simulator (HFSS). (1008). Ver. 11, Ansoft Corporation, Pittsburgh, PA."},{"key":"ijmstr.2013010102-11","doi-asserted-by":"crossref","unstructured":"Huang, W., & Kishk, A. A. (2011). Embedded spiral microstrip implantable antenna. Hindawi International Journal of Antennas and Propagation, 1-6.","DOI":"10.1155\/2011\/919821"},{"key":"ijmstr.2013010102-12","unstructured":"IEEE. (1999). IEEE Standard for safety levels with respect to human exposure to radiofrequency electromagnetic fields, 3 kHz to 300 GHz. IEEE Standard C95.1-1999."},{"key":"ijmstr.2013010102-13","unstructured":"IEEE. (2005). IEEE Standard for safety levels with respect to human exposure to radiofrequency electromagnetic fields, 3 kHz to 300 GHz. IEEE Standard C95.1-2005. International Telecommunications Union-Radiocommunications (ITU-R). Radio regulations, section 5.138 and 5.150. ITU, Geneva, Switzerland. Retrieved from http:\/\/itu.int\/home"},{"key":"ijmstr.2013010102-14","doi-asserted-by":"publisher","DOI":"10.1109\/TMTT.2008.919373"},{"key":"ijmstr.2013010102-15","doi-asserted-by":"crossref","unstructured":"Kiourti, A., Christopoulou, M., & Nikita, K. S. (2011a). Performance of a novel miniature antenna implanted in the human head for wireless biotelemetry. IEEE International Symposium on Antennas and Propagation.","DOI":"10.1109\/APS.2011.5996726"},{"key":"ijmstr.2013010102-16","doi-asserted-by":"crossref","unstructured":"Kiourti, A., & Nikita, K. S. (2011b). Meandered versus spiral novel miniature PIFAs implanted in the human head: tuning and performance. In Proceedings of the 2nd ICST International Conference on Wireless Mobile Communication and Healthcare.","DOI":"10.1007\/978-3-642-29734-2_12"},{"key":"ijmstr.2013010102-17","doi-asserted-by":"publisher","DOI":"10.1109\/MAP.2012.6293992"},{"key":"ijmstr.2013010102-18","doi-asserted-by":"publisher","DOI":"10.1109\/TAP.2012.2201078"},{"key":"ijmstr.2013010102-19","doi-asserted-by":"publisher","DOI":"10.1002\/bem.21753"},{"key":"ijmstr.2013010102-20","doi-asserted-by":"crossref","unstructured":"Kiourti, A., & Nikita, K. S. (2012d). Performance of miniature implantable antennas for medical telemetry at 402, 433, 868 and 915 MHz. In Proceedings of the 3rd International ICST Conference on Wireless Mobile Communication and Healthcare (MobiHealth 2012).","DOI":"10.1007\/978-3-642-37893-5_14"},{"key":"ijmstr.2013010102-21","doi-asserted-by":"crossref","unstructured":"Kiourti, A., & Nikita, K. S. (2012e). Detuning issues and performance of a novel implantable antenna for telemetry applications. In Proceedings of the 6th European Conference on Antennas and Propagation (EuCAP 2012).","DOI":"10.1109\/EuCAP.2012.6206560"},{"key":"ijmstr.2013010102-22","doi-asserted-by":"publisher","DOI":"10.1163\/156939308786375181"},{"key":"ijmstr.2013010102-23","unstructured":"Notis, D. T., Liakou, P. C., & Chrissoulidis, D. P. (2004). Dual polarized microstrip patch antenna, reduced in size by use of peripheral slits. In Proceedings of the European Conference on Wireless Technologies."},{"key":"ijmstr.2013010102-24","doi-asserted-by":"publisher","DOI":"10.1109\/TMTT.2009.2029770"},{"key":"ijmstr.2013010102-25","doi-asserted-by":"publisher","DOI":"10.1109\/10.828152"},{"key":"ijmstr.2013010102-26","doi-asserted-by":"publisher","DOI":"10.1109\/10.568919"},{"key":"ijmstr.2013010102-27","doi-asserted-by":"publisher","DOI":"10.1002\/bem.10122"},{"key":"ijmstr.2013010102-28","doi-asserted-by":"publisher","DOI":"10.1109\/TBME.2007.900550"},{"key":"ijmstr.2013010102-29","doi-asserted-by":"publisher","DOI":"10.1109\/10.324525"},{"key":"ijmstr.2013010102-30","doi-asserted-by":"publisher","DOI":"10.1109\/TAP.2005.848461"},{"key":"ijmstr.2013010102-31","doi-asserted-by":"publisher","DOI":"10.1109\/TBME.1987.326039"},{"key":"ijmstr.2013010102-32","unstructured":"Wegmueller, M. S., Oberle, M., Kuster, N., & Fichtner, W. (2006). From dielectrical properties of human tissue to intra-body communications. In Proceedings of the World Congress on Medical Physics in Biomedical Engineering."},{"key":"ijmstr.2013010102-33","doi-asserted-by":"crossref","unstructured":"Wessels, D. (2002). Implantable pacemakers and defibrillators: Device overview and EMI considerations. In Proceedings of the IEEE International Symposium on Electromagnetic Compatibility.","DOI":"10.1109\/ISEMC.2002.1032815"},{"key":"ijmstr.2013010102-34","doi-asserted-by":"publisher","DOI":"10.1088\/0031-9155\/53\/13\/019"},{"key":"ijmstr.2013010102-35","doi-asserted-by":"publisher","DOI":"10.1109\/TAP.2009.2024459"}],"container-title":["International Journal of Monitoring and Surveillance Technologies Research"],"original-title":[],"language":"ng","link":[{"URL":"https:\/\/www.igi-global.com\/viewtitle.aspx?TitleId=78550","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2022,6,1]],"date-time":"2022-06-01T16:45:23Z","timestamp":1654101923000},"score":1,"resource":{"primary":{"URL":"https:\/\/services.igi-global.com\/resolvedoi\/resolve.aspx?doi=10.4018\/ijmstr.2013010102"}},"subtitle":["Dependence upon Operation Frequency, Tissue Anatomy, and Implantation Site"],"short-title":[],"issued":{"date-parts":[[2013,1,1]]},"references-count":36,"journal-issue":{"issue":"1","published-print":{"date-parts":[[2013,1]]}},"URL":"https:\/\/doi.org\/10.4018\/ijmstr.2013010102","relation":{},"ISSN":["2166-7241","2166-725X"],"issn-type":[{"value":"2166-7241","type":"print"},{"value":"2166-725X","type":"electronic"}],"subject":[],"published":{"date-parts":[[2013,1,1]]}}}