{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,5,2]],"date-time":"2025-05-02T04:06:32Z","timestamp":1746158792063,"version":"3.40.4"},"reference-count":53,"publisher":"IGI Global","issue":"3","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":[],"published-print":{"date-parts":[[2013,7,1]]},"abstract":"<p>Healthcare solutions using anytime, and anywhere remote healthcare surveillance devices, have become a major challenge. The patients with chronic diseases who need only therapeutic supervision are not advised to occupy a hospital bed. Using Wearable Wireless Body\/Personal Area Network (WWBAN), intelligent monitoring of heart can supply information about medical conditions. Electrocardiogram (ECG) is the core reference in the diagnosis and medication process. An approach on healthcare solution WBAN based, for real-time ECG signal monitoring and long-term recording will be presented. Low-power wireless sensor nodes with local processing and encoding capabilities in order to achieve maximum mobility and flexibility are our main goal. ZigBee wireless technology will be used for transmission. Sensor device will be programmed to process locally the ECG signal and to raise an alert. Low-power and miniaturization are essential physical requirements.<\/p>","DOI":"10.4018\/ijmstr.2013070102","type":"journal-article","created":{"date-parts":[[2013,12,30]],"date-time":"2013-12-30T16:23:10Z","timestamp":1388420590000},"page":"20-37","source":"Crossref","is-referenced-by-count":1,"title":["WBAN Based Long Term ECG Monitoring"],"prefix":"10.4018","volume":"1","author":[{"given":"Marius","family":"Rosu","sequence":"first","affiliation":[{"name":"Department for Applied Electronics and Information Engineering, University \u201cPolitehnica\u201d of Bucharest, Bucharest, Romania"}]},{"given":"Sever","family":"Pasca","sequence":"additional","affiliation":[{"name":"IEEE Member, Department for Applied Electronics and Information Engineering, University \u201cPolitehnica\u201d of Bucharest, Bucharest, Romania"}]}],"member":"2432","reference":[{"key":"ijmstr.2013070102-0","doi-asserted-by":"crossref","unstructured":"Atallah, L., Lo, B., Yang, G. Z., & Siegemund, F. (2008). Wirelessly accessible sensor populations (WASP) for elderly care monitoring. In Proceedings of the Second International Conference on Pervasive Computing Technologies for Healthcare (pp. 2\u20137).","DOI":"10.4108\/ICST.PERVASIVEHEALTH2008.2777"},{"key":"ijmstr.2013070102-1","doi-asserted-by":"crossref","unstructured":"Baker, C., Armijo, K., Belka, S., Benhabib, M., Bhargava, V., & Burkhart, N. \u2026 Wright, P. (2007). Wireless sensor networks for home health care. In Proceedings of the 21st International Conference on Advanced Information Networking and Applications Workshops (vol. 2, pp. 832\u2013837).","DOI":"10.1109\/AINAW.2007.376"},{"key":"ijmstr.2013070102-2","unstructured":"Bao, S., Zhang, Y., & Shen, L. (2005). Physiological signal based entity authentication for body area sensor networks and mobile healthcare systems. In Proceedings of the 27th Annual International Conference of the IEEE EMBS (pp. 2455\u20132458)."},{"key":"ijmstr.2013070102-3","doi-asserted-by":"crossref","unstructured":"Barth, A. T., Hanson, M. A., Powell, H. C., Jr., & Lach, J. (2009). Tempo 3.1: A body area sensor network platform for continuous movement assessment. In Proceedings of the 6th International Workshop on Wearable and Implantable Body Sensor Networks (pp. 71\u201376). IEEE Computer Society.","DOI":"10.1109\/BSN.2009.39"},{"key":"ijmstr.2013070102-4","doi-asserted-by":"crossref","unstructured":"Benhaddou, D., Balakrishnan, M., & Yuan, X. (2008). Remote healthcare monitoring system architecture using sensor networks. In Proceedings of the IEEE Region 5 Conference, Kansas City, MO (pp. 1\u20136).","DOI":"10.1109\/TPSD.2008.4562760"},{"key":"ijmstr.2013070102-5","doi-asserted-by":"crossref","unstructured":"Borges, L. M., Barroca, N., & Lebres, A. S. (2009). Smart-clothing wireless flex sensor belt network for foetal health monitoring. In Proceedings of the 3rd International Conference on Pervasive Computing Technologies for Healthcare (pp. 1\u20134).","DOI":"10.4108\/ICST.PERVASIVEHEALTH2009.6028"},{"key":"ijmstr.2013070102-6","doi-asserted-by":"crossref","unstructured":"Casas, R., Blasco Mar\u00edn, R., Robinet, A., Delgado, A. R., Yarza, A. R., Mcginn, J., et al. (2008). User modelling in ambient intelligence for elderly and disabled people. In Proceedings of the 11th International Conference on Computers Helping People with Special Needs (pp. 114\u2013122). Springer-Verlag.","DOI":"10.1007\/978-3-540-70540-6_15"},{"key":"ijmstr.2013070102-7","doi-asserted-by":"publisher","DOI":"10.1007\/BF00998853"},{"key":"ijmstr.2013070102-8","doi-asserted-by":"publisher","DOI":"10.3390\/s110605561"},{"key":"ijmstr.2013070102-9","unstructured":"DecaWave.com. (n.d.). Retrieved from http:\/\/www.idtechex.com\/events\/presentations\/scensor_an_ieee802_15_4a_uwb_compliant_chip_ripe_for_energy_harvesing_001824.asp"},{"key":"ijmstr.2013070102-10","doi-asserted-by":"publisher","DOI":"10.1016\/j.comnet.2009.03.016"},{"key":"ijmstr.2013070102-11","doi-asserted-by":"publisher","DOI":"10.1109\/MCOM.2006.1632658"},{"key":"ijmstr.2013070102-12","unstructured":"DIGI. (n.d.). http:\/\/www.digi.com\/"},{"key":"ijmstr.2013070102-13","doi-asserted-by":"crossref","unstructured":"Durmus, Y., Ozgovde, A., & Ersoy, C. (2009). Event based queueing for fairness and on-time delivery in video surveillance sensor networks. In Proceedings of the IFIP Networking.","DOI":"10.1007\/978-3-642-01399-7_4"},{"key":"ijmstr.2013070102-14","doi-asserted-by":"crossref","unstructured":"Fang, W., Chen, J., Shu, L., Chu, T. S., & Qian, D. (2010). Congestion avoidance, detection and alleviation in wireless sensor networks. Journal of Zhejiang University \u2013 Science C, 11(1), 63\u201373.","DOI":"10.1631\/jzus.C0910204"},{"key":"ijmstr.2013070102-15","unstructured":"Gao, T., Greenspan, D., Welsh, M., Juang, R. R., & Alm, A. (2005). Vital signs monitoring and patient tracking over a wireless network. In Proceedings of the 27th Annual International Conference of the IEEE EMBS."},{"key":"ijmstr.2013070102-16","doi-asserted-by":"crossref","unstructured":"Gietzelt, M., Wolf, K.-H., Marschollek, M., & Haux, R. (2008). Automatic selfcalibration of body worn triaxial-accelerometers for application in healthcare. In Proceedings of the Second International Conference on Pervasive Computing Technologies for Healthcare (pp. 177\u2013180).","DOI":"10.4108\/ICST.PERVASIVEHEALTH2008.2537"},{"issue":"11","key":"ijmstr.2013070102-17","doi-asserted-by":"crossref","first-page":"6799","DOI":"10.3390\/s110706799","article-title":"A comprehensive ubiquitous healthcare solution on an android\u2122 mobile device.","author":"P.-C.Hii","year":"2011","journal-title":"Journal of Sensors"},{"key":"ijmstr.2013070102-18","doi-asserted-by":"crossref","unstructured":"Hill, J., Szewczyk, R., Woo, A., Hollar, S., Culler, D. E., & Pister, K. S. J. (2000). System architecture directions for networked sensors. In Architectural support for programming languages and operating systems (pp. 93\u2013104).","DOI":"10.1145\/384264.379006"},{"key":"ijmstr.2013070102-19","doi-asserted-by":"crossref","unstructured":"Hori, T., Nishida, Y., Suehiro, T., & Hirai, S. (200). SELF-network: Design and implementation of network for distributed embedded sensors. In Proceedings of the IEEE\/RSJ International Conference on Intelligent Robots and Systems (Vol. 2, 1373\u20131378).","DOI":"10.1109\/IROS.2000.893212"},{"key":"ijmstr.2013070102-20","unstructured":"Ikonen, V., & Kaasinen, E. (2008). Ethical assessment in the design of ambient assisted living. In Assisted living systems \u2013 Models, architectures and engineering approaches."},{"key":"ijmstr.2013070102-21","unstructured":"Institute of Electrical and Electronics Engineers, Inc. (n.d.). IEEE 802.15.4. draft standard. Retrieved from http:\/\/grouper.ieee.org\/groups\/802\/15\/pub\/TG4.html"},{"key":"ijmstr.2013070102-22","doi-asserted-by":"crossref","unstructured":"Jasemian, Y. (2008). Elderly comfort and compliance to modern telemedicine system at home. In Proceedings of the Second International Conference on Pervasive Computing Technologies for Healthcare.","DOI":"10.4108\/ICST.PERVASIVEHEALTH2008.2516"},{"key":"ijmstr.2013070102-23","unstructured":"Lauterbach, C., Strasser, M., Jung, S., & Weber, W. (2002). Smart clothes selfpowered by body heat. In Proceedings of the Avantex Symposium."},{"key":"ijmstr.2013070102-24","doi-asserted-by":"crossref","unstructured":"Leonov, V., Fiorini, P., Sedky, S., Torfs, T., & Van Hoof, C. (2005). Thermoelectric MEMS generators as a power supply for a body area network. In Proceedings of the 13th International Conference on Solid-State Sensors, Actuators and Microsystems (vol. 1, pp. 291\u2013294).","DOI":"10.1109\/SENSOR.2005.1496414"},{"key":"ijmstr.2013070102-25","doi-asserted-by":"crossref","unstructured":"Li, Z., & Zhang, G. (2007). A physical activities healthcare system based on wireless sensing technology. In Proceedings of the 13th IEEE International Conference on Embedded and Real-Time Computing Systems and Applications.","DOI":"10.1109\/RTCSA.2007.10"},{"key":"ijmstr.2013070102-26","unstructured":"Malan, D., Fulford-Jones, T., Welsh, M., & Moulton, S. (2004). Code blue: An ad hoc sensor network infrastructure for emergency medical care. In Proceedings of the International Workshop on Wearable and Implantable Body Sensor Networks."},{"key":"ijmstr.2013070102-27","doi-asserted-by":"crossref","unstructured":"Malmivuo, J., & Plonsey, R. (1995). Bioelectromagnetism - Principles and applications of bioelectric and biomagnetic fields. New York, NY: Oxford University Press. Retrieved from http:\/\/www.bem.fi\/book\/","DOI":"10.1093\/acprof:oso\/9780195058239.001.0001"},{"key":"ijmstr.2013070102-28","doi-asserted-by":"crossref","unstructured":"Marinkovic, S., & Popovici, S. (2009). Network coding for efficient error recovery in wireless sensor networks for medical applications. In Proceedings of the International Conference on Emerging Network Intelligence (pp. 15-20). IEEE Computer Society.","DOI":"10.1109\/EMERGING.2009.22"},{"key":"ijmstr.2013070102-29","doi-asserted-by":"crossref","unstructured":"Misic, J. (2008). Enforcing patient privacy in healthcare WSNs using ECC implemented on 802.15.4 beacon enabled clusters. In Proceedings of the Sixth Annual IEEE International Conference on Pervasive Computing and Communications (pp. 686\u2013691). Washington, DC: IEEE Computer Society.","DOI":"10.1109\/PERCOM.2008.28"},{"key":"ijmstr.2013070102-30","doi-asserted-by":"crossref","unstructured":"Mori, Y., Yamauchi, M., & Kaneko, K. (2000). Design and implementation of the Vital Sign Box for home healthcare. In Proceedings of the IEEE EMBS International Conference on Information Technology Applications in Biomedicine (pp. 104\u2013109).","DOI":"10.1109\/ITAB.2000.892358"},{"key":"ijmstr.2013070102-31","unstructured":"Otto, C., Milenkovic, A., Sanders, C., & Jovanov, E. (2006). System architecture of a wireless body area sensor network for ubiquitous health monitoring. JMM, 2006(1), 307-326."},{"key":"ijmstr.2013070102-32","doi-asserted-by":"publisher","DOI":"10.1109\/TITB.2009.2025817"},{"key":"ijmstr.2013070102-33","unstructured":"Pereira, P., Grilo, A., Rocha, F., Nunes, M., Casaca, A., & Chaudet, C. \u2026 Johansson, M. (2003). End-to-end reliability in wireless sensor networks: Survey and research challenges. In Proceedings of the EuroFGI Workshop on IP QoS and Traffic Control (pp. 67\u201374)."},{"key":"ijmstr.2013070102-34","unstructured":"Purwar, A., Jeong, D. U., & Chung, W. Y. (2007). Activity monitoring from realtime triaxial accelerometer data using sensor network. In Proceedings of the International Conference on Control, Automation and Systems (pp. 2402\u20132406)."},{"key":"ijmstr.2013070102-35","doi-asserted-by":"publisher","DOI":"10.1016\/j.sna.2007.11.005"},{"key":"ijmstr.2013070102-36","doi-asserted-by":"crossref","unstructured":"Rosu, M., & Pasca, S. (2013). A WBAN-ECG approach for real-time long-term monitoring. In Proceedings of the 8th International Symposium on Advanced Topics in Electrical Engineering (ATEE), Bucharest.","DOI":"10.1109\/ATEE.2013.6563426"},{"key":"ijmstr.2013070102-37","doi-asserted-by":"crossref","unstructured":"Sankarasubramaniam, Y., Akan, O. B., & Akyildiz, I. F. (2003). ESRT: Event tosink reliable transport in wireless sensor networks. In Proceedings of the 4th ACM International Symposium on Mobile Ad Hoc Networking and Computing.","DOI":"10.1145\/778415.778437"},{"key":"ijmstr.2013070102-38","doi-asserted-by":"crossref","unstructured":"Shnayder, V., Chen, B., Lorincz, K., Fulford-Jones, T. R. F., & Welsh, M. (2005). Sensor networks for medical care. In Proceedings of the 3rd International Conference on Embedded Networked Sensor Systems.","DOI":"10.1145\/1098918.1098979"},{"key":"ijmstr.2013070102-39","doi-asserted-by":"crossref","unstructured":"Srinivasan, V., Stankovic, J., & Whitehouse, K. (2008). Protecting your daily inhome activity information from a wireless snooping attack. In Proceedings of the 10th International Conference on Ubiquitous Computing (pp. 202\u2013211). ACM.","DOI":"10.1145\/1409635.1409663"},{"key":"ijmstr.2013070102-40","unstructured":"Stankovic, J. A., Cao, Q., Doan, T., Fang, L., He, Z., & Kiran, R. \u2026 Wood, A. (2005). Wireless sensor networks for in-home healthcare: potential and challenges. In Proceedings of the High Confidence Medical Device Software and Systems (HCMDSS) Workshop."},{"key":"ijmstr.2013070102-41","doi-asserted-by":"publisher","DOI":"10.1186\/1743-0003-2-17"},{"key":"ijmstr.2013070102-42","doi-asserted-by":"crossref","unstructured":"Taccini, N., Loriga, G., Dittmar, A., & Paradiso, R. (2004). Knitted includes for health monitoring. In Proceedings of the 26th Annual International Conference of the IEEE IEMBS (vol. 1, pp. 2165\u20132168).","DOI":"10.1109\/IEMBS.2004.1403633"},{"key":"ijmstr.2013070102-43","doi-asserted-by":"crossref","unstructured":"Tang, Q., Tummala, N., Gupta, S. K. S., & Schwiebert, L. (2005). TARA: Thermalaware routing algorithm for implanted sensor networks. In Proceedings of the 1st IEEE International Conference on Distributed Computing in Sensor Systems (DCOSS\u201905) (pp. 206217).","DOI":"10.1007\/11502593_17"},{"key":"ijmstr.2013070102-44","unstructured":"TI. (n.d.). Retrieved from http:\/\/www.ti.com\/"},{"key":"ijmstr.2013070102-45","doi-asserted-by":"publisher","DOI":"10.1080\/00207217.2011.609981"},{"key":"ijmstr.2013070102-46","unstructured":"Vijayalakshmi, S. R., & Muruganand, S. (2012). Spyder wireless ECG monitoring. Web Biotechnology Pte., Ltd., Singapore. Retrieved from http:\/\/www.web-biotech.com\/news"},{"journal-title":"Wireless pulse\/ECG watch","year":"2012","author":"S. R.Vijayalakshmi","key":"ijmstr.2013070102-47"},{"key":"ijmstr.2013070102-48","doi-asserted-by":"crossref","unstructured":"von Steinburg, S. P., Boulesteix, A.-L., Lederer, C., Grunow, S., Schiermeier, S., & Hatzmann, W. \u2026 Daumer, M. (2013). What is the \u201cnormal\u201d fetal heart rate? Peer J., 2013(1), e82. Retrieved from https:\/\/peerj.com\/articles\/82\/","DOI":"10.7717\/peerj.82"},{"key":"ijmstr.2013070102-49","first-page":"145","author":"G. Z.Yand","year":"2006","journal-title":"Body sensor networks"},{"key":"ijmstr.2013070102-50","doi-asserted-by":"publisher","DOI":"10.1109\/JSSC.2009.2034440"},{"key":"ijmstr.2013070102-51","doi-asserted-by":"publisher","DOI":"10.1016\/j.sna.2010.06.004"},{"key":"ijmstr.2013070102-52","doi-asserted-by":"crossref","unstructured":"Zhang, G. H., Poon, C. C. Y., Li, Y., & Zhang, Y. T. (2009). A biometric method to secure telemedicine systems. In Proceedings of the 31st Annual International Conference of the IEEE Engineering in Medicine and Biology Society (vol. 1, pp. 701\u2013704).","DOI":"10.1109\/IEMBS.2009.5332470"}],"container-title":["International Journal of Monitoring and Surveillance Technologies Research"],"original-title":[],"language":"ng","link":[{"URL":"https:\/\/www.igi-global.com\/viewtitle.aspx?TitleId=97699","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,5,1]],"date-time":"2025-05-01T10:18:08Z","timestamp":1746094688000},"score":1,"resource":{"primary":{"URL":"https:\/\/services.igi-global.com\/resolvedoi\/resolve.aspx?doi=10.4018\/ijmstr.2013070102"}},"subtitle":[""],"short-title":[],"issued":{"date-parts":[[2013,7,1]]},"references-count":53,"journal-issue":{"issue":"3","published-print":{"date-parts":[[2013,7]]}},"URL":"https:\/\/doi.org\/10.4018\/ijmstr.2013070102","relation":{},"ISSN":["2166-7241","2166-725X"],"issn-type":[{"type":"print","value":"2166-7241"},{"type":"electronic","value":"2166-725X"}],"subject":[],"published":{"date-parts":[[2013,7,1]]}}}