{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,6,10]],"date-time":"2026-06-10T15:23:03Z","timestamp":1781104983182,"version":"3.54.1"},"reference-count":23,"publisher":"IGI Global Scientific Publishing","issue":"3","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":[],"published-print":{"date-parts":[[2013,7,1]]},"abstract":"<p>An unobtrusive bed integrated system for monitoring physiological parameters during sleep is presented and evaluated. The system uses textile electrodes attached to a bed sheet for measuring multiple channels of electrocardiogram. The channels are also combined in order to form several additional ECG leads. One lead at a time is selected for beat-to-beat-interval detection. The system also includes force sensors located under a bed post for detecting respiration and movements. The movement information is also used to assist in heart rate detection and combining the ECG derived respiration information with respiration information derived from force sensors, is investigated. The authors tested the system with ten subjects in one hour recordings and achieved an average of 95.9% detection coverage and 99 percentile absolute error of 3.47 ms for the BB-interval signal. The relative mean absolute error of the detected respiration cycle lengths was 2.1%.<\/p>","DOI":"10.4018\/ijmstr.2013070104","type":"journal-article","created":{"date-parts":[[2013,12,30]],"date-time":"2013-12-30T11:23:10Z","timestamp":1388402590000},"page":"52-67","source":"Crossref","is-referenced-by-count":1,"title":["Combining the Information of Unconstrained Electrocardiography and Ballistography in the Detection of Night-Time Heart Rate and Respiration Rate"],"prefix":"10.4018","volume":"1","author":[{"given":"Antti","family":"Vehkaoja","sequence":"first","affiliation":[{"name":"Department of Automation Science and Engineering, Tampere University of Technology (TUT), Tampere, Finland"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Mikko","family":"Peltokangas","sequence":"additional","affiliation":[{"name":"Department of Automation Science and Engineering, Tampere University of Technology (TUT), Tampere, Finland"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jarmo","family":"Verho","sequence":"additional","affiliation":[{"name":"Department of Automation Science and Engineering, Tampere University of Technology (TUT), Tampere, Finland"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jukka","family":"Lekkala","sequence":"additional","affiliation":[{"name":"Department of Automation Science and Engineering, Tampere University of Technology (TUT), Tampere, Finland"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"2432","reference":[{"key":"ijmstr.2013070104-0","doi-asserted-by":"crossref","unstructured":"Avci, C., Besli, S., & Akbas, A. (2011). Performance of the EDR methods: Evaluations using the mean and instantaneous respiration rates. In Proceeding of 5th International Conference on Bioinformatics and Biomedical Engineering (iCBBE) (pp.1-5).","DOI":"10.1109\/icbbe.2011.5780180"},{"key":"ijmstr.2013070104-1","doi-asserted-by":"publisher","DOI":"10.1016\/S1389-9457(03)00111-4"},{"issue":"5","key":"ijmstr.2013070104-2","first-page":"778","article-title":"Adaptive beat-to-beat heart rate estimation in ballistocardiograms. Information Technology in Biomedicine","volume":"15","author":"C.Br\u00fcser","year":"2011","journal-title":"IEEE Transactions on"},{"key":"ijmstr.2013070104-3","doi-asserted-by":"publisher","DOI":"10.1007\/s00421-010-1359-0"},{"key":"ijmstr.2013070104-4","doi-asserted-by":"publisher","DOI":"10.1007\/s10439-008-9580-2"},{"key":"ijmstr.2013070104-5","doi-asserted-by":"crossref","unstructured":"Devot, S., Bianchi, A., Naujokat, E., Mendez, M., Brauers, A., & Cerutti, S. (2007). Sleep monitoring through a textile recording system. In Proc. 29th Annual Int Conf of the IEEE Engineering in Medicine and Biology Society (EMBC) (pp. 2560\u20132563).","DOI":"10.1109\/IEMBS.2007.4352851"},{"key":"ijmstr.2013070104-6","doi-asserted-by":"publisher","DOI":"10.1097\/01.PSY.0000106884.58744.09"},{"key":"ijmstr.2013070104-7","doi-asserted-by":"crossref","unstructured":"Ishida, S., Shiozawa, N., Fujiwara, Y., & Makikawa, M. (2007). Electrocardiogram measurement during sleep with wearing clothes using capacitively coupled electrodes. In Proc. 29th Annual Int Conf of the IEEE Engineering in Medicine and Biology Society (EMBC) (pp. 2647\u20132650).","DOI":"10.1109\/IEMBS.2007.4352873"},{"key":"ijmstr.2013070104-8","doi-asserted-by":"publisher","DOI":"10.1007\/BF02510978"},{"key":"ijmstr.2013070104-9","doi-asserted-by":"publisher","DOI":"10.1016\/S1350-4533(97)00013-1"},{"issue":"3","key":"ijmstr.2013070104-10","first-page":"776","article-title":"Sleep staging based on signals acquired through bed sensor. Information Technology in Biomedicine","volume":"14","author":"J.Kortelainen","year":"2010","journal-title":"IEEE Transactions on"},{"issue":"4","key":"ijmstr.2013070104-11","first-page":"718","article-title":"ECG recording on a bed during sleep without direct skin-contact. Biomedical Engineering","volume":"54","author":"Y.Lim","year":"2007","journal-title":"IEEE Transactions on"},{"key":"ijmstr.2013070104-12","doi-asserted-by":"publisher","DOI":"10.2307\/2532051"},{"key":"ijmstr.2013070104-13","doi-asserted-by":"publisher","DOI":"10.1378\/chest.10-1872"},{"key":"ijmstr.2013070104-14","doi-asserted-by":"publisher","DOI":"10.1016\/j.bspc.2012.06.001"},{"key":"ijmstr.2013070104-15","doi-asserted-by":"crossref","unstructured":"Paalasmaa, J., Leppakorpi, L., & Partinen, M. (2011). Quantifying respiratory variation with force sensor measurements. In Proc. 33rd Annual Int Conf of the IEEE Engineering in Medicine and Biology Society (EMBC) (pp. 3812\u20133815).","DOI":"10.1109\/IEMBS.2011.6090773"},{"issue":"5","key":"ijmstr.2013070104-16","first-page":"935","article-title":"Night-time EKG and HRV monitoring with bed sheet integrated textile electrodes. Information Technology in Biomedicine","volume":"16","author":"M.Peltokangas","year":"2012","journal-title":"IEEE Transactions on"},{"key":"ijmstr.2013070104-17","unstructured":"Puurtinen, M. (2012). Precordial bipolar leads for mobile ECG applications. Doctoral dissertation."},{"key":"ijmstr.2013070104-18","doi-asserted-by":"publisher","DOI":"10.1161\/01.CIR.100.13.1411"},{"key":"ijmstr.2013070104-19","doi-asserted-by":"crossref","unstructured":"Vehkaoja, A., Peltokangas, M., Verho, J., & Lekkala, J. (2012). Combining unobtrusive electrocardiography and ballistography for more accurate monitoring of sleep. In Proceedings of the IEEE 12th International Conference on Bioinformatics & Bioengineering (BIBE) (pp.202-207).","DOI":"10.1109\/BIBE.2012.6399674"},{"key":"ijmstr.2013070104-20","doi-asserted-by":"publisher","DOI":"10.1177\/1045389X03014003006"},{"key":"ijmstr.2013070104-21","doi-asserted-by":"publisher","DOI":"10.1109\/ITAB.2008.4570586"},{"key":"ijmstr.2013070104-22","doi-asserted-by":"crossref","unstructured":"Zhengzhong, G., Fanxue, K., & Xu, Z. (2011). Accurate and rapid QRS detection for intelligent ECG monitor. In Proceeding of Third International Conference on Measuring Technology and Mechatronics Automation (ICMTMA) (pp. 298\u2013301).","DOI":"10.1109\/ICMTMA.2011.76"}],"container-title":["International Journal of Monitoring and Surveillance Technologies Research"],"original-title":[],"language":"ng","link":[{"URL":"https:\/\/www.igi-global.com\/viewtitle.aspx?TitleId=97701","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2022,6,1]],"date-time":"2022-06-01T23:43:52Z","timestamp":1654127032000},"score":1,"resource":{"primary":{"URL":"https:\/\/services.igi-global.com\/resolvedoi\/resolve.aspx?doi=10.4018\/ijmstr.2013070104"}},"subtitle":[""],"short-title":[],"issued":{"date-parts":[[2013,7,1]]},"references-count":23,"journal-issue":{"issue":"3","published-print":{"date-parts":[[2013,7]]}},"URL":"https:\/\/doi.org\/10.4018\/ijmstr.2013070104","relation":{},"ISSN":["2166-7241","2166-725X"],"issn-type":[{"value":"2166-7241","type":"print"},{"value":"2166-725X","type":"electronic"}],"subject":[],"published":{"date-parts":[[2013,7,1]]}}}