{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,6,10]],"date-time":"2026-06-10T15:41:45Z","timestamp":1781106105066,"version":"3.54.1"},"reference-count":42,"publisher":"IGI Global Scientific Publishing","issue":"4","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":[],"published-print":{"date-parts":[[2013,10,1]]},"abstract":"<p>A prototype magnetic resonance imaging (MRI)-compatible positioning device that navigates a high intensity focused ultrasound (HIFU) transducer is presented. The intended application is to treat eventually tumours in the abdominal and thyroid. The positioning device has 3 user-controlled stages that allow access to various targets using a top to bottom coupling approach. Materials and Methods. The positioning device incorporates only MRI compatible materials such as piezoelectric motors, ABS plastic, brass screws, and brass rack and pinion. Results The MRI compatibility and the accuracy of the system were successfully demonstrated in an open MRI scanner. The robot has the ability to accurately move the transducer thus creating discrete and overlapping lesions in rabbit liver in vivo. This simple, cost effective positioning device can be placed mostly on the structure of an open MRI gantry. Due to the size of this positioning device, the proposed prototype in its current form cannot be used in any closed MRI system. The novelty of this positioning device is the MRI compatible design and its intended application which is the treatment of tumors in the abdominal area using focused ultrasound. This system can be utilized in the future to treat patients with cancer in the liver, kidney, pancreas and thyroid provided that the accuracy of the positioning device is greatly improved.<\/p>","DOI":"10.4018\/ijmstr.2013100105","type":"journal-article","created":{"date-parts":[[2014,2,25]],"date-time":"2014-02-25T14:24:36Z","timestamp":1393338276000},"page":"48-60","source":"Crossref","is-referenced-by-count":2,"title":["A Prototype MR Compatible Positioning Device for Guiding a Focused Ultrasound System for the Treatment of Abdominal and Thyroid Cancer"],"prefix":"10.4018","volume":"1","author":[{"given":"Nicos","family":"Mylonas","sequence":"first","affiliation":[{"name":"Frederick University Cyprus, Limassol, Cyprus & City University, London, UK"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Christakis","family":"Damianou","sequence":"additional","affiliation":[{"name":"Cyprus University of Technology, Limassol, Cyprus"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"2432","reference":[{"key":"ijmstr.2013100105-0","doi-asserted-by":"publisher","DOI":"10.1016\/0090-4295(94)90214-3"},{"issue":"22","key":"ijmstr.2013100105-1","first-page":"53","article-title":"In vivo effects of high-intensity ultrasound on prostatic adenocarcinoma, Dunning R3327.","volume":"52","author":"J. Y.Chapelon","year":"1992","journal-title":"Cancer Research"},{"key":"ijmstr.2013100105-2","first-page":"153","article-title":"Towards MRI guided surgical manipulator.","volume":"7","author":"K.Chinzei","year":"2001","journal-title":"Medical Science Monitor"},{"key":"ijmstr.2013100105-3","author":"R.Chopra","year":"2009","journal-title":"An MRI-compatible system for focused ultrasound experiments in small animal models"},{"key":"ijmstr.2013100105-4","doi-asserted-by":"publisher","DOI":"10.1097\/00004728-199211000-00024"},{"key":"ijmstr.2013100105-5","doi-asserted-by":"publisher","DOI":"10.1007\/s11548-007-0145-x"},{"key":"ijmstr.2013100105-6","doi-asserted-by":"publisher","DOI":"10.1089\/thy.2011.0141"},{"issue":"Pt 2","key":"ijmstr.2013100105-7","first-page":"509","article-title":"MRI compatibility of robot actuation techniques \u2013 A comparative study.","volume":"11","author":"G.Fischer","year":"2008","journal-title":"Med Image Comput Comput Assist Interv"},{"key":"ijmstr.2013100105-8","doi-asserted-by":"publisher","DOI":"10.1109\/EMB.2007.910273"},{"key":"ijmstr.2013100105-9","doi-asserted-by":"crossref","unstructured":"Hata, N., Hashimoto, R., Tokuda, J., et al. (2005). Needle guiding robot for MR-guided microwave thermotherapy of liver tumor using motorized remote-center-of-motion constraint. In Proc. of IEEE International Conference on Robotics & Automation., Barcelona, Spain (pp. 1652-1656).","DOI":"10.1109\/ROBOT.2005.1570350"},{"key":"ijmstr.2013100105-10","doi-asserted-by":"publisher","DOI":"10.3109\/10929080309146052"},{"key":"ijmstr.2013100105-11","first-page":"8441","article-title":"A new noninvasive approach in breast cancer therapy using magnetic resonance imaging-guided focused ultrasound surgery.","volume":"61","author":"P.Huber","year":"2001","journal-title":"Cancer Research"},{"key":"ijmstr.2013100105-12","doi-asserted-by":"publisher","DOI":"10.1002\/jmri.1880050306"},{"key":"ijmstr.2013100105-13","doi-asserted-by":"publisher","DOI":"10.1097\/00004424-199410000-00006"},{"key":"ijmstr.2013100105-14","doi-asserted-by":"publisher","DOI":"10.1118\/1.597093"},{"key":"ijmstr.2013100105-15","doi-asserted-by":"publisher","DOI":"10.1148\/radiology.219.1.r01ap02176"},{"key":"ijmstr.2013100105-16","doi-asserted-by":"publisher","DOI":"10.1002\/jmri.1880010516"},{"key":"ijmstr.2013100105-17","doi-asserted-by":"publisher","DOI":"10.1097\/00004424-200008000-00008"},{"key":"ijmstr.2013100105-18","doi-asserted-by":"crossref","unstructured":"Koseki, Y., Washio, T., Chinzei, K., et al. (2002). Endoscope manipulator for trans-nasal neurosurgery, optimized for and compatible to vertical field open MRI. In Proc. Of MICCAI '02 Lecture Notes in Computer Science (Vol. 2488, pp. 114\u201321).","DOI":"10.1007\/3-540-45786-0_15"},{"key":"ijmstr.2013100105-19","doi-asserted-by":"crossref","unstructured":"Krieger, A., Song, S. E., Bongjoon Cho, N., Iordachita, I. I., Guion, P., Fichtinger, G., & Whitcomb, L. L. (2013). Development and evaluation of an actuated MRI-compatible robotic system for MRI-guided prostate intervention. Mechatronics, IEEE\/ASME Transactions on, 18(1), 273-284.","DOI":"10.1109\/TMECH.2011.2163523"},{"key":"ijmstr.2013100105-20","doi-asserted-by":"publisher","DOI":"10.1115\/1.1785803"},{"key":"ijmstr.2013100105-21","doi-asserted-by":"crossref","first-page":"494","DOI":"10.1113\/jphysiol.1962.sp006862","article-title":"A simple method for production of trackless focal lesions with focused ultrasound.","volume":"160","author":"P. P.Lele","year":"1962","journal-title":"The Journal of Physiology"},{"key":"ijmstr.2013100105-22","doi-asserted-by":"crossref","unstructured":"Li, M., Mazilu, D., & Horvath, K. (2008). Robotic system for transapical aortic valve replacement with MRI guidance. Proc. of MICCAI '08 Lecture Notes in Computer Science. 5242, 476-484.","DOI":"10.1007\/978-3-540-85990-1_57"},{"key":"ijmstr.2013100105-23","doi-asserted-by":"publisher","DOI":"10.1001\/archsurg.1973.01350240053015"},{"key":"ijmstr.2013100105-24","doi-asserted-by":"publisher","DOI":"10.1016\/j.ultrasmedbio.2010.10.001"},{"key":"ijmstr.2013100105-25","first-page":"350","article-title":"Experimental, ultrasonically induced lesions in the retina, choroid, and sclera.","volume":"205","author":"F.Lizzi","year":"1978","journal-title":"Investigative Ophthalmology & Visual Science"},{"key":"ijmstr.2013100105-26","doi-asserted-by":"publisher","DOI":"10.1002\/(SICI)1522-712X(1995)1:4<242::AID-IGS7>3.0.CO;2-A"},{"key":"ijmstr.2013100105-27","first-page":"22","article-title":"MRI-guided high intensity focused ultrasound (HIFU) An alternative form of non-invasive out-patient treatment in oncology.","volume":"1","author":"C.Moonen","year":"2008","journal-title":"OncoSolutions"},{"key":"ijmstr.2013100105-28","first-page":"331","article-title":"MR-imaging guided focused ultrasound therapy for breast fibroadenomas: A feasibility study.","volume":"197","author":"O. H.Pomeroy","year":"1995","journal-title":"Radiology"},{"key":"ijmstr.2013100105-29","doi-asserted-by":"publisher","DOI":"10.1109\/TMECH.2011.2106795"},{"key":"ijmstr.2013100105-30","doi-asserted-by":"publisher","DOI":"10.1002\/rcs.394"},{"key":"ijmstr.2013100105-31","doi-asserted-by":"publisher","DOI":"10.1016\/j.fertnstert.2005.04.072"},{"key":"ijmstr.2013100105-32","doi-asserted-by":"crossref","unstructured":"Su, H., Cardona, D., Shang, W., Cole, G., Rucker, C., Webster, R., III, & Fischer, G. S. (2012). MRI-guided concentric tube continuum robot with piezoelectric actuation: A feasibility study. In Proceedings of the IEEE ICRA 2012 International Conference on Robotics and Automation, Saint Paul, MN.","DOI":"10.1109\/ICRA.2012.6224550"},{"key":"ijmstr.2013100105-33","doi-asserted-by":"crossref","unstructured":"Su, H., Zervas, M., Cole, G., Furlong, C., & Fischer, G. (2011). Real-time MRI-guided needle placement robot with integrated fiber optic force sensing. In Proceedings of the IEEE ICRA 2011 International Conference on Robotics and Automation, Shanghai, China (pp. 1583-1588).","DOI":"10.1109\/ICRA.2011.5979539"},{"key":"ijmstr.2013100105-34","doi-asserted-by":"publisher","DOI":"10.1148\/radiol.2283020911"},{"key":"ijmstr.2013100105-35","doi-asserted-by":"publisher","DOI":"10.1088\/0031-9155\/34\/11\/021"},{"issue":"9","key":"ijmstr.2013100105-36","first-page":"14","article-title":"Image-guided focused ultrasound gains ground as noninvasive therapeutic tool.","volume":"13","author":"M.Thompson","year":"2011","journal-title":"Medical Insight"},{"key":"ijmstr.2013100105-37","doi-asserted-by":"crossref","unstructured":"Tsekos, N. V., Shudy, J., Yacoub, E., Tsekos, P. V., & Koutlas, I. G. (2001). Development of a robotic device for MRI-guided interventions in the breast. In Proceedings of the 2nd IEEE International Symposium on Bioinformatics and Bioengineering, Washington, DC.","DOI":"10.1109\/BIBE.2001.974430"},{"key":"ijmstr.2013100105-38","unstructured":"Verghese, T., Palathinkara, V., Massat, M. B., McGill, J., & Weichelt, M. (2011). Innovation and achievement in advancing MR-guided therapeutics (pp. 64-68). GE Signa Pulse, a GE Healthcare MR publication."},{"key":"ijmstr.2013100105-39","doi-asserted-by":"publisher","DOI":"10.1016\/0301-5629(94)90058-2"},{"key":"ijmstr.2013100105-40","doi-asserted-by":"crossref","unstructured":"Wu, F., Wang, Z. B., Zhu, H., Chen, W. Z., Zou, J. Z., Bai, J., \u2026 Su, H. B. (2005). Extracorporeal high intensity focused ultrasound treatment for patients with breast cancer. 92(1), 51-60.","DOI":"10.1007\/s10549-004-5778-7"},{"key":"ijmstr.2013100105-41","unstructured":"Yehezkeli, O., Freundlich, D., Magen, N., Marantz, C., Medan, Y., Vitek, S., & Weinreb, A. (2002). INSIGHTEC-TXSONICSLTD. Mechanical positioner for MRI guided ultrasound therapy system WO0209812."}],"container-title":["International Journal of Monitoring and Surveillance Technologies Research"],"original-title":[],"language":"ng","link":[{"URL":"https:\/\/www.igi-global.com\/viewtitle.aspx?TitleId=101965","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2022,6,1]],"date-time":"2022-06-01T18:01:44Z","timestamp":1654106504000},"score":1,"resource":{"primary":{"URL":"https:\/\/services.igi-global.com\/resolvedoi\/resolve.aspx?doi=10.4018\/ijmstr.2013100105"}},"subtitle":[""],"short-title":[],"issued":{"date-parts":[[2013,10,1]]},"references-count":42,"journal-issue":{"issue":"4","published-print":{"date-parts":[[2013,10]]}},"URL":"https:\/\/doi.org\/10.4018\/ijmstr.2013100105","relation":{},"ISSN":["2166-7241","2166-725X"],"issn-type":[{"value":"2166-7241","type":"print"},{"value":"2166-725X","type":"electronic"}],"subject":[],"published":{"date-parts":[[2013,10,1]]}}}