{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2023,7,8]],"date-time":"2023-07-08T10:10:25Z","timestamp":1688811025522},"reference-count":27,"publisher":"IGI Global","issue":"3","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":[],"published-print":{"date-parts":[[2013,7,1]]},"abstract":"<p>This work presents the development of an affordable optical motion-capture system which uses home video cameras for 2D and 3D gait analysis. The 2D gait analyzer system consists of one camcorder and one PC while the 3D gait analyzer system uses two camcorders, a flash and two PCs. Both systems make use of 25 fps camcorder, LED markers and technical computing software to track motions of markers attached to human body during walking. In the experiment for 3D gait analyzer system, the two cameras are synchronized by using flash. The recorded videos for both systems are extracted into frames and then converted into binary images, and bridge morphological operation is applied for unconnected pixel to facilitate marker detection process. Least distance method is then employed to track the markers motions, and 3D Direct Linear Transformation is used to reconstruct 3D markers positions. The correlation between length in pixel and in the real world resulted from calibration process is used to reconstruct 2D markers positions. To evaluate the reliability of the 2D and 3D optical motion-capture system developed in the present work, spatio-temporal and kinematics parameters calculated from the obtained markers positions are qualitatively compared with the ones from literature, and the results show good compatibility.<\/p>","DOI":"10.4018\/jehmc.2013070103","type":"journal-article","created":{"date-parts":[[2013,11,22]],"date-time":"2013-11-22T19:09:15Z","timestamp":1385147355000},"page":"36-52","source":"Crossref","is-referenced-by-count":4,"title":["Tracking of Markers for 2D and 3D Gait Analysis Using Home Video Cameras"],"prefix":"10.4018","volume":"4","author":[{"given":"Sandro","family":"Mihradi","sequence":"first","affiliation":[{"name":"Faculty of Mechanical and Aerospace Engineering, Institut Teknologi Bandung, Bandung, Indonesia"}]},{"family":"Ferryanto","sequence":"additional","affiliation":[{"name":"Faculty of Mechanical and Aerospace Engineering, Institut Teknologi Bandung, Bandung, Indonesia"}]},{"given":"Tatacipta","family":"Dirgantara","sequence":"additional","affiliation":[{"name":"Faculty of Mechanical and Aerospace Engineering, Institut Teknologi Bandung, Bandung, Indonesia"}]},{"given":"Andi I.","family":"Mahyuddin","sequence":"additional","affiliation":[{"name":"Faculty of Mechanical and Aerospace Engineering, Institut Teknologi Bandung, Bandung, Indonesia"}]}],"member":"2432","reference":[{"key":"jehmc.2013070103-0","unstructured":"Abdel-Aziz, Y. I., & Karara, H. M. (1971). Direct linear transformation from comparator coordinates into object space coordinates. American Society of Photogrammetry Symposium on Close-Range Photogrammetry, 1-18."},{"key":"jehmc.2013070103-1","doi-asserted-by":"publisher","DOI":"10.1115\/1.2891200"},{"key":"jehmc.2013070103-2","doi-asserted-by":"publisher","DOI":"10.1093\/ageing\/26.1.15"},{"key":"jehmc.2013070103-3","first-page":"583","article-title":"Hemiplegic gait: analysis of temporal variables.","volume":"64","author":"M. E.Brandstater","year":"1983","journal-title":"Archives of Physical Medicine and Rehabilitation"},{"key":"jehmc.2013070103-4","unstructured":"Henda, A. I. (2011). Software development for 3D kinematics analysis of human walking (in Indonesian). Undergraduate Thesis. Mechanical Engineering Dept. Institut Teknologi Bandung, Bandung, Indonesia."},{"key":"jehmc.2013070103-5","doi-asserted-by":"publisher","DOI":"10.1249\/00005768-198820020-00010"},{"key":"jehmc.2013070103-6","author":"R. L.Huston","year":"2009","journal-title":"Principle of Biomechanics"},{"key":"jehmc.2013070103-7","unstructured":"Jaya, A. S., Dirgantara, T., Mahyuddin, A. I., & Mihradi, S. (2010, February). Robust algorithms of marker image processing in automatic human gait analysis. In Proceedings of the Regional Conference on Mechanical and Aerospace Technology, Bali, Indonesia."},{"key":"jehmc.2013070103-8","unstructured":"Juliyad, N., Mihradi, S., Dirgantara, T., & Mahyuddin, A. I. (2010, February). 2D experimental motion analysis of human gait. In Proceedings of the Regional Conference on Mechanical and Aerospace Technology, Bali, Indonesia."},{"key":"jehmc.2013070103-9","unstructured":"Kwon, Y. (1998). Direct linear transformation (DLT). Retrieved September 19, 2011, from http:\/\/www.kwon3D.com\/theory\/DLT\/DLT.html#3D"},{"key":"jehmc.2013070103-10","doi-asserted-by":"crossref","unstructured":"Mahyuddin, A. I., Mihradi, S., Dirgantara, T., Juliyad, N., & Purba, U. (2010). Development of an affordable system for 2d kinematics and dynamics analysis of human walking. In C. Quan, K. Qian, A. Asundi, F. S. Chau (Eds.), Proc. of SPIE Vol. 7522, 75222L\u00b7\u00a92010 SPIE - doi: 10.1117\/12.851654.","DOI":"10.1117\/12.851654"},{"key":"jehmc.2013070103-11","doi-asserted-by":"publisher","DOI":"10.4028\/www.scientific.net\/AMM.83.123"},{"key":"jehmc.2013070103-12","unstructured":"Maulido, P. N. (2011). Development of Indonesian normal gait database using 2-d motion analyzer (in Indonesian). Undergraduate Thesis. Mechanical Engineering Dept., Institut Teknologi Bandung, Bandung, Indonesia."},{"key":"jehmc.2013070103-13","author":"V.Medved","year":"2001","journal-title":"Measurement of human locomotion"},{"key":"jehmc.2013070103-14","first-page":"309","article-title":"Work and power in gait of stroke patients.","volume":"72","author":"S. J.Olney","year":"1991","journal-title":"Archives of Physical Medicine and Rehabilitation"},{"key":"jehmc.2013070103-15","doi-asserted-by":"crossref","DOI":"10.1007\/b102366","author":"J. F.Orr","year":"1997","journal-title":"Optical measurement methods in biomechanics"},{"key":"jehmc.2013070103-16","doi-asserted-by":"crossref","first-page":"637","DOI":"10.1093\/ptj\/74.7.637","article-title":"A comparison of gait characteristics in young and old subjects.","volume":"74","author":"K. M.Ostrosky","year":"1994","journal-title":"Physical Therapy"},{"key":"jehmc.2013070103-17","author":"J.Perry","year":"1992","journal-title":"Gait analysis: Normal and pathological function"},{"key":"jehmc.2013070103-18","year":"1989","journal-title":"Observational gait analysis handbook"},{"key":"jehmc.2013070103-19","doi-asserted-by":"publisher","DOI":"10.1016\/S0167-9457(99)00023-8"},{"key":"jehmc.2013070103-20","first-page":"95","article-title":"Standardization of kinematic gait measurements and automatic pathological gait pattern diagnostics.","volume":"9","author":"U.Stanic","year":"1977","journal-title":"Scandinavian Journal of Rehabilitation Medicine"},{"key":"jehmc.2013070103-21","first-page":"81","article-title":"Impairment and walking disability following stroke: A multi-centre study.","volume":"11","author":"J.Steadman","year":"1997","journal-title":"Clinical Rehabilitation"},{"key":"jehmc.2013070103-22","doi-asserted-by":"crossref","first-page":"213","DOI":"10.1016\/S0004-9514(14)60388-3","article-title":"Use of a video time display in determining general gait measures.","volume":"42","author":"B.Stillman","year":"1996","journal-title":"Australian Physiotherapy"},{"key":"jehmc.2013070103-23","author":"C. L.Vaughan","year":"1999","journal-title":"Dynamic of human gait"},{"key":"jehmc.2013070103-24","doi-asserted-by":"publisher","DOI":"10.1016\/S0031-9406(05)67156-8"},{"key":"jehmc.2013070103-25","author":"M. W.Whittle","year":"2007","journal-title":"Gait analysis: An introduction"},{"key":"jehmc.2013070103-26","doi-asserted-by":"publisher","DOI":"10.1002\/9780470549148"}],"container-title":["International Journal of E-Health and Medical Communications"],"original-title":[],"language":"ng","link":[{"URL":"https:\/\/www.igi-global.com\/viewtitle.aspx?TitleId=94632","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,7,8]],"date-time":"2023-07-08T09:55:57Z","timestamp":1688810157000},"score":1,"resource":{"primary":{"URL":"https:\/\/services.igi-global.com\/resolvedoi\/resolve.aspx?doi=10.4018\/jehmc.2013070103"}},"subtitle":[""],"short-title":[],"issued":{"date-parts":[[2013,7,1]]},"references-count":27,"journal-issue":{"issue":"3","published-print":{"date-parts":[[2013,7]]}},"URL":"https:\/\/doi.org\/10.4018\/jehmc.2013070103","relation":{},"ISSN":["1947-315X","1947-3168"],"issn-type":[{"value":"1947-315X","type":"print"},{"value":"1947-3168","type":"electronic"}],"subject":[],"published":{"date-parts":[[2013,7,1]]}}}