{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,6,10]],"date-time":"2026-06-10T17:02:04Z","timestamp":1781110924098,"version":"3.54.1"},"reference-count":44,"publisher":"IGI Global Scientific Publishing","issue":"1","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":[],"published-print":{"date-parts":[[2013,1,1]]},"abstract":"<p>Researches on green data centers have defined guidelines and end-to-end methodologies to increase energy efficiency. Most of these approaches require a disrupting reengineering of the infrastructure and significant upfront investments. Smaller data centers need to reach green objectives with a more incremental approach. The EnergIT project proposes a methodology and related tools that support the incremental redesign of data centers toward greater energy efficiency based on three main levers: 1) physical repositioning of servers to optimize air flow circulation and cooling, enabling higher set temperatures of the cooling system; 2) replacement of server models; and 3) virtualization. This paper describes the approach and provides evidence on the effectiveness of the methodology by showing how the combined effect of the three levers has led to 62% reduction of energy consumption in a real case study.<\/p>","DOI":"10.4018\/jgc.2013010106","type":"journal-article","created":{"date-parts":[[2013,8,14]],"date-time":"2013-08-14T12:56:22Z","timestamp":1376484982000},"page":"83-111","source":"Crossref","is-referenced-by-count":5,"title":["EnergIT"],"prefix":"10.4018","volume":"4","author":[{"given":"Eugenio","family":"Capra","sequence":"first","affiliation":[{"name":"Dipartimento di Elettronica e Informazione, Politecnico di Milano, Milano, Italy"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Paolo","family":"Cremonesi","sequence":"additional","affiliation":[{"name":"Dipartimento di Elettronica e Informazione, Politecnico di Milano, Milano, Italy"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Chiara","family":"Francalanci","sequence":"additional","affiliation":[{"name":"Dipartimento di Elettronica e Informazione, Politecnico di Milano, Milano, Italy"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Francesco","family":"Merlo","sequence":"additional","affiliation":[{"name":"Dipartimento di Elettronica e Informazione, Politecnico di Milano, Milano, Italy"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Nicola","family":"Parolini","sequence":"additional","affiliation":[{"name":"Dipartimento di Matematica, Politecnico di Milano, Milano, Italy"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"2432","reference":[{"key":"jgc.2013010106-0","doi-asserted-by":"publisher","DOI":"10.1016\/j.jpdc.2009.08.009"},{"key":"jgc.2013010106-1","doi-asserted-by":"publisher","DOI":"10.1016\/j.jpdc.2005.12.005"},{"key":"jgc.2013010106-2","doi-asserted-by":"crossref","unstructured":"Ardagna, D., Francalanci, C., Piuri, V., & Scotti, F. (2004) Evolutionary design of information systems architectures. In Proceedings of the 7th International Conference on Artificial Intelligence and Soft Computing (ICAISC), Zakopane, Poland.","DOI":"10.1007\/978-3-540-24844-6_1"},{"issue":"2","key":"jgc.2013010106-3","article-title":"Joint optimization of hardware and network costs for distributed computer systems.","volume":"38","author":"D.Ardagna","year":"2008","journal-title":"IEEE Transactions on Systems, Man, and Cybernetics"},{"key":"jgc.2013010106-4","author":"C.Bash","year":"2007","journal-title":"Cool job allocation: Measuring the power savings of placing jobs at cooling-efficient locations in the data center (Technical Report, HPL-2007-62)"},{"key":"jgc.2013010106-5","doi-asserted-by":"publisher","DOI":"10.1093\/comjnl\/bxp080"},{"key":"jgc.2013010106-6","doi-asserted-by":"crossref","unstructured":"Bhopte, S., Agonafer, D., Schmidt, R., & Sammakia, B. (2006). Optimization of data center room layout to minimize rack inlet air temperature. Transactions of the ASME, 128.","DOI":"10.1115\/IPACK2005-73027"},{"key":"jgc.2013010106-7","author":"J. P.Bigus","year":"2000","journal-title":"AutoTune: A generic agent for automated performance tuning. Practical Applications of Intelligent Agents and Multi-Agent Systems"},{"key":"jgc.2013010106-8","doi-asserted-by":"crossref","unstructured":"Bohrer, P., Elmootazbellah, N., Elnozahy, N., Keller, T., Kistler, M., & Lefurgy, C. \u2026 Rajamony, R. (2002). The case for power management in web servers. In Graybill R., & Melhem, R. (Eds.), Power aware computing (pp. 261-289). Norwell, MA: Kluwer Academic Publishers.","DOI":"10.1007\/978-1-4757-6217-4_14"},{"key":"jgc.2013010106-9","doi-asserted-by":"crossref","unstructured":"Brooks, D., Tiwari, V., & Martonosi, M. (2000). Wattch: A framework for architectural-level power analysis and optimizations (pp. 83\u201394).","DOI":"10.1145\/342001.339657"},{"key":"jgc.2013010106-10","doi-asserted-by":"publisher","DOI":"10.1145\/1716383.1730791"},{"key":"jgc.2013010106-11","doi-asserted-by":"publisher","DOI":"10.1109\/MC.2005.380"},{"key":"jgc.2013010106-12","doi-asserted-by":"crossref","unstructured":"Chiaraviglio, L., & Matta, I. (2010). GreenCoop: Cooperative green routing with energy-efficient servers. In Proceedings of the 1st ACM International Conference on Energy-Efficient Computing and Networking, New York, NY (pp. 191-194).","DOI":"10.1145\/1791314.1791345"},{"key":"jgc.2013010106-13","unstructured":"Economou, D., Rivoire, S., Kozyrakis, C., & Ranganathan, P. (2006). Full-system power analysis and modeling for server environments. Workshop on Modeling, Benchmarking, and Simulation (MoBS), International Symposium on Computer Architecture (ISCA)."},{"key":"jgc.2013010106-14","doi-asserted-by":"publisher","DOI":"10.1109\/TSMCA.2009.2027133"},{"key":"jgc.2013010106-15","author":"D. E.Goldberg","year":"1989","journal-title":"Genetic algorithms in search, optimization and machine learning"},{"key":"jgc.2013010106-16","doi-asserted-by":"crossref","unstructured":"Gurumurthi, S., Sivasubramaniam, A., Irwin, M. J., Vijaykrishnan, N., Kandemir, M., Li, T., & Kurian, L. (2002). Using complete machine simulation for software power estimation: The SoftWatt approach. In Proceedings of the 8th International Symposium on High-Performance Computer Architecture, Washington, DC.","DOI":"10.1109\/HPCA.2002.995705"},{"key":"jgc.2013010106-17","unstructured":"Hamilton, J. (2006). Architecture for modular data centers. Retrieved from http:\/\/arxiv.org\/abs\/cs\/0612110"},{"key":"jgc.2013010106-18","unstructured":"Hsu, C. H., & Feng, W. C. (2005). A power-aware run-time system for high-performance computing. In Proceedings of the 2005 ACM\/IEEE Conference on Supercomputing, Washington DC."},{"key":"jgc.2013010106-19","unstructured":"Koza, J. R. (1998). Genetic programming. Encyclopedia of Computer Science and Technology, 39, 29-43."},{"key":"jgc.2013010106-20","doi-asserted-by":"publisher","DOI":"10.1109\/ICAC.2008.31"},{"key":"jgc.2013010106-21","doi-asserted-by":"publisher","DOI":"10.1109\/ICAC.2007.35"},{"key":"jgc.2013010106-22","doi-asserted-by":"publisher","DOI":"10.1007\/s10619-007-7009-9"},{"key":"jgc.2013010106-23","doi-asserted-by":"publisher","DOI":"10.1287\/opre.9.3.383"},{"key":"jgc.2013010106-24","doi-asserted-by":"crossref","unstructured":"Liu, L., Wang, H., Liu, X., Jin, X., Bo He, W., Bo Wang, Q., & Chen, Y. (2009). GreenCloud: A new architecture for green data center. In Proceedings of the 6th International Conference on Autonomic Computing and Communications.","DOI":"10.1145\/1555312.1555319"},{"key":"jgc.2013010106-25","doi-asserted-by":"publisher","DOI":"10.1145\/1508284.1508269"},{"key":"jgc.2013010106-26","doi-asserted-by":"crossref","unstructured":"Miyakawa, D., & Ishikawa, Y. (2007). Process Oriented Power Management. In Proceedings of the IEEE International Symposium in Industrial Embedded Systems.","DOI":"10.1109\/SIES.2007.4297310"},{"key":"jgc.2013010106-27","unstructured":"Moore, J., Chase, J., Ranganathan, P., & Sharma, R. (2005). Making scheduling \u201ccool\u201d: Temperature-aware workload placement in data center. In Proceedings of USENIX Annual Conference."},{"key":"jgc.2013010106-28","doi-asserted-by":"publisher","DOI":"10.1145\/1594233.1594268"},{"key":"jgc.2013010106-29","author":"C. D.Patel","year":"2005","journal-title":"Cost model for planning, development and operation of a data center (Technical Report, HPL-2005-107R1)"},{"key":"jgc.2013010106-30","author":"C. D.Patel","year":"2002","journal-title":"Energy aware grid: Global workload placement based on energy efficiency"},{"key":"jgc.2013010106-31","doi-asserted-by":"publisher","DOI":"10.1145\/1791314.1791350"},{"key":"jgc.2013010106-32","doi-asserted-by":"publisher","DOI":"10.1080\/10407780500496562"},{"key":"jgc.2013010106-33","doi-asserted-by":"publisher","DOI":"10.1007\/s10619-006-7007-3"},{"key":"jgc.2013010106-34","author":"F.Rawson","year":"2004","journal-title":"Mempower: A simple memory power analysis tool set"},{"key":"jgc.2013010106-35","unstructured":"Rivoire, S., Ranganathan, P., & Kozyrakis, C. (2008). A comparison of high-level full-system power models. Workshop on Power Aware Computing and Systems (HotPower)."},{"key":"jgc.2013010106-36","unstructured":"Sawyer, R. (2004). Calculating energy requirements for data centers. APC White Paper."},{"key":"jgc.2013010106-37","doi-asserted-by":"publisher","DOI":"10.1201\/9781420086676"},{"key":"jgc.2013010106-38","doi-asserted-by":"publisher","DOI":"10.1147\/rd.475.0641"},{"key":"jgc.2013010106-39","doi-asserted-by":"publisher","DOI":"10.1115\/1.2787024"},{"key":"jgc.2013010106-40","unstructured":"Tarek, A., Enawy, A., & Aydin, H. (2005). Energy-aware task allocation for rate monotonic scheduling. In Proceedings of the 11th IEEE Real Time on Embedded Technology and Applications Symposium, Washington, DC."},{"key":"jgc.2013010106-41","author":"A.Vasan","year":"2010","journal-title":"Worth their watts? An empirical study of data center servers"},{"key":"jgc.2013010106-42","doi-asserted-by":"publisher","DOI":"10.1145\/342001.339659"},{"key":"jgc.2013010106-43","unstructured":"Zedlewski, J., Sobti, S., Garg, N., Zheng, F., Krishnamurthy, A., & Wang, R. (2003). Modeling hard-disk power consumption. In Proceedings of the 2nd USENIX Conference on File and Storage Technologies. Berkeley, CA."}],"container-title":["International Journal of Green Computing"],"original-title":[],"language":"ng","link":[{"URL":"https:\/\/www.igi-global.com\/viewtitle.aspx?TitleId=80241","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2022,6,1]],"date-time":"2022-06-01T18:40:36Z","timestamp":1654108836000},"score":1,"resource":{"primary":{"URL":"https:\/\/services.igi-global.com\/resolvedoi\/resolve.aspx?doi=10.4018\/jgc.2013010106"}},"subtitle":["A Methodology for the Incremental Green Design of Data Centers"],"short-title":[],"issued":{"date-parts":[[2013,1,1]]},"references-count":44,"journal-issue":{"issue":"1","published-print":{"date-parts":[[2013,1]]}},"URL":"https:\/\/doi.org\/10.4018\/jgc.2013010106","relation":{},"ISSN":["1948-5018","1948-5026"],"issn-type":[{"value":"1948-5018","type":"print"},{"value":"1948-5026","type":"electronic"}],"subject":[],"published":{"date-parts":[[2013,1,1]]}}}