{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2023,11,25]],"date-time":"2023-11-25T00:20:30Z","timestamp":1700871630765},"reference-count":14,"publisher":"Trans Tech Publications, Ltd.","license":[{"start":{"date-parts":[[2014,2,27]],"date-time":"2014-02-27T00:00:00Z","timestamp":1393459200000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/www.scientific.net\/PolicyAndEthics\/PublishingPolicies"},{"start":{"date-parts":[[2014,2,27]],"date-time":"2014-02-27T00:00:00Z","timestamp":1393459200000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.scientific.net\/license\/TDM_Licenser.pdf"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["AMR"],"abstract":"<jats:p>As reason of increasing requirements of thermal insulation properties of the exposed envelope, reflective insulation are among kind of modern thermal insulation materials ones, which can significantly increased thermal insulation performance if their application is correct. Thermal insulation performance is caused by reduction of the heat transfer by radiation. Conjunction of low-emissivity surface of the reflective insulation and air layer is important to account. This article is focused on the determination of thermal properties of reflective insulation and the results of measured values thermal resistance of determination by hot box method using heat flow meter are presented here. As part of determination of thermal properties of reflective insulation by experimental methods, the test element used to measure the thermal resistance of an insulated air cavity had to be created for concordance with the normative requirements. The part of this article is determination of the thermal resistance by the calculation of derived physical relations and comparison with values of the laboratory measurement.<\/jats:p>","DOI":"10.4028\/www.scientific.net\/amr.899.374","type":"journal-article","created":{"date-parts":[[2014,2,27]],"date-time":"2014-02-27T09:33:11Z","timestamp":1393493591000},"page":"374-380","source":"Crossref","is-referenced-by-count":1,"title":["Calculation and Experimental Evaluation of the Thermal Resistance of a Structure with Reflective Insulation"],"prefix":"10.4028","volume":"899","author":[{"given":"Ji\u0159\u00ed","family":"Kal\u00e1nek","sequence":"first","affiliation":[{"name":"V\u0160B- Technical University of Ostrava"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Libor","family":"\u0160teffek","sequence":"additional","affiliation":[{"name":"V\u0160B- Technical University of Ostrava"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Milan","family":"Ostr\u00fd","sequence":"additional","affiliation":[{"name":"V\u0160B- Technical University of Ostrava"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"2457","published-online":{"date-parts":[[2014,2,27]]},"reference":[{"key":"959988","unstructured":"Act No. 406\/2000 Coll. - On energy managment and related regulations, Czech Republic (Z\u00e1kon \u010d. 406\/2000 Sb.: o hospoda\u0159en\u00ed energi\u00ed, ve zn\u011bn\u00ed pozd\u011bj\u0161\u00edch p\u0159edpis\u016f)."},{"key":"959989","unstructured":"Decree No. 78\/2013 Coll. - on the energy performance of buildings, Czech Republic (Vyhl\u00e1\u0161ka \u010d. 78\/2013 Sb.: o energetick\u00e9 n\u00e1ro\u010dnosti budov)."},{"key":"959990","unstructured":"\u010cSN 73 0540-2: 2011+Z1: 2012 Thermal protection of buildings - Part 2: Requirements (Tepeln\u00e1 ochrana budov - \u010d\u00e1st 2: Po\u017eadavky)."},{"key":"959991","unstructured":"T. Pet\u0159\u00ed\u010dek, P. Kac\u00e1lek, R. Smolka. Skladby \u0161ikm\u00e9 st\u0159echy a vhodn\u00e1 aplikace tepeln\u00e9 izolace. In: Brno, 2011, Available: http: \/www. fce. vutbr. cz\/veda\/JUNIORSTAV2011\/pdf\/1. 2."},{"key":"959992","doi-asserted-by":"publisher","unstructured":"M.J. Tenpierik, E. Hasselaar. Reflective multi-foil insulations for buildings: A review.\u00a0Energy and buildings. 2013, vol. 56.","DOI":"10.1016\/j.enbuild.2012.10.003"},{"key":"959993","doi-asserted-by":"publisher","unstructured":"M. Belusko F. Bruno, W. Saman. Investigation of the thermal resistance of timber attic spaces with reflective foil and bulk insulation, heat flow up. Applied energy. 2011, vol. 88, no. 1.","DOI":"10.1016\/j.apenergy.2010.07.017"},{"key":"959994","doi-asserted-by":"crossref","unstructured":"I.E. Smith; S. Probert. Effectiveness of reflective foil as thermal insulation. Applied energy. 1979, vol. 5, no. 1.","DOI":"10.1016\/0306-2619(79)90008-4"},{"key":"959995","unstructured":"Reflective Insulation, Radiant Barriers And Radiation Control Coatings.\u00a0RIMA International\u00a0[online]. 2002 [cit. 2013-09-12]. Available: http: \/www. rimainternational. org\/wp-content\/uploads\/2011\/02\/handbook. pdf."},{"key":"959996","doi-asserted-by":"publisher","unstructured":"EN 6946 Building components and building elements - Thermal resistance and thermal transmittance - Calculation method. (Stavebn\u00ed prvky a stavebn\u00ed konstrukce - Tepeln\u00fd odpor a sou\u010dinitel prostupu tepla - V\u00fdpo\u010dtov\u00e1 metoda).","DOI":"10.3403\/00942964u"},{"key":"959997","doi-asserted-by":"publisher","unstructured":"EN 16012. Thermal insulation for buildings - Reflective insulation products - Determination of the declared thermal performance. (Tepeln\u00e1 izolace budov \u2013 reflexn\u00ed izola\u010dn\u00ed v\u00fdrobky \u2013 stanoven\u00ed deklarovan\u00fdch tepeln\u00fdch vlastnost\u00ed).","DOI":"10.3403\/30206131u"},{"key":"959998","doi-asserted-by":"publisher","unstructured":"EN 8990 Thermal insulation - Determination of steady state thermal transmission properties - Calibrated and guarded hot box (Tepeln\u00e1 izolace - Stanoven\u00ed vlastnost\u00ed prostupu tepla v ust\u00e1len\u00e9m stavu - Kalibrovan\u00e1 a chr\u00e1n\u011bn\u00e1 tepl\u00e1 sk\u0159\u00ed\u0148).","DOI":"10.3403\/00916705u"},{"key":"959999","unstructured":"Authors archives."},{"key":"960000","doi-asserted-by":"publisher","unstructured":"G. Lopez, L. Basterra, L. Acuna. Determination of the Emissivity of Wood for Inspection by Infrared Thermography. Journal of nondestructive evaluation. 2013, vol. 32, no. 2.","DOI":"10.1007\/s10921-013-0170-3"},{"key":"960001","unstructured":"S. \u0160\u0165astn\u00edk, J. Hollan, R. Steuer. Mo\u017enosti ur\u010den\u00ed emisivity materi\u00e1l\u016f pomoc\u00ed infra\u010derven\u00e9 termografie. Http: \/amper. ped. muni. cz [online]. [cit. 2013-12-11]. Available from: http: \/amper. ped. muni. cz\/jenik\/LW-infrared."}],"container-title":["Advanced Materials Research"],"original-title":[],"link":[{"URL":"https:\/\/www.scientific.net\/AMR.899.374.pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,11,24]],"date-time":"2023-11-24T21:02:21Z","timestamp":1700859741000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.scientific.net\/AMR.899.374"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2014,2,27]]},"references-count":14,"URL":"https:\/\/doi.org\/10.4028\/www.scientific.net\/amr.899.374","relation":{},"ISSN":["1662-8985"],"issn-type":[{"value":"1662-8985","type":"electronic"}],"subject":[],"published":{"date-parts":[[2014,2,27]]}}}