{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,11,27]],"date-time":"2025-11-27T20:52:18Z","timestamp":1764276738945,"version":"3.40.5"},"reference-count":12,"publisher":"Trans Tech Publications, Ltd.","license":[{"start":{"date-parts":[[2014,8,11]],"date-time":"2014-08-11T00:00:00Z","timestamp":1407715200000},"content-version":"vor","delay-in-days":10,"URL":"https:\/\/www.scientific.net\/PolicyAndEthics\/PublishingPolicies"},{"start":{"date-parts":[[2014,8,11]],"date-time":"2014-08-11T00:00:00Z","timestamp":1407715200000},"content-version":"tdm","delay-in-days":10,"URL":"https:\/\/www.scientific.net\/license\/TDM_Licenser.pdf"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["AMR"],"abstract":"<jats:p>The development of designing building structures exposed to fire is solved not only on the basis of data obtained by standardized tabular values from the fire tests, but also by calculations or their combination with standard values. Calculation methods are becoming more important for most types of building structures, especially for timber and steel building structures. One possibility how to define thermal load of building structures, which is usable especially immediately after the development of a fire, is local fire method. This paper summarizes the principles of calculation while using local fire, it evaluates its positive and negative characteristics, and especially its practical applicability.<\/jats:p>","DOI":"10.4028\/www.scientific.net\/amr.1001.362","type":"journal-article","created":{"date-parts":[[2014,8,11]],"date-time":"2014-08-11T16:15:37Z","timestamp":1407773737000},"page":"362-367","source":"Crossref","is-referenced-by-count":3,"title":["Specific Knowledge in Assessment of Local Fire for Design of Building Structures"],"prefix":"10.4028","volume":"1001","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-1829-8437","authenticated-orcid":false,"given":"Ji\u0159\u00ed","family":"Pokorn\u00fd","sequence":"first","affiliation":[{"name":"Fire Rescue Service of Moravian-Silesian Region"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Petr","family":"Ku\u010dera","sequence":"additional","affiliation":[{"name":"VSB \u2013 Technical University of Ostrava"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Vladim\u00edr","family":"Vl\u010dek","sequence":"additional","affiliation":[{"name":"Fire Rescue Service of Moravian-Silesian Region"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"2457","published-online":{"date-parts":[[2014,8]]},"reference":[{"key":"688865","unstructured":"Regulation (EU) No 305\/2011 of The European Parliament and of the Council \u2013 laying down harmonised for the marketing of construction products and repealing Council Directive 89\/106\/EEC. Official Journal of the European Union L 88\/5. Strasbourg. (2011)."},{"key":"688866","doi-asserted-by":"publisher","unstructured":"\u010cSN EN 1991-1-2: Eurocode 1: Actions on structures - Part 1-2: General actions - Actions on structures exposed to fire. Prague: Czech Office for Standards, Metrology and Testing, (2004), 56 p. (in Czech).","DOI":"10.1002\/9783433601570.ch8"},{"key":"688867","unstructured":"\u010cSN 73 0804: Fire protection of buildings - Industrial buildings. Prague: Czech Office for Standards, Metrology and Testing, (2010) 156\u00a0p. (in Czech)."},{"key":"688868","unstructured":"Toma\u0161kov\u00e1, M. Study of Psychological Strain of Firefighters. In: EIIC 2012: Electronic International Interdisciplinary Conference, 3-7 September 2012: virtual peer-reviewed conference. \u017dilina: EDIS, (2012)."},{"key":"688869","unstructured":"\u010cSN 73 0810 (2009). Fire Protection of Buildings \u2013 General requirements. Prague: Czech Office for Standards, Metrology and Testing, (2009) 44\u00a0p. (in Czech)."},{"key":"688870","doi-asserted-by":"publisher","unstructured":"Pokorn\u00fd, J., Ku\u010dera, P. Calculation of Local Fire for Designing Building Structures. In TRANSACTIONS of the V\u0160B - Technical University of Ostrava, Safety Engineering Series, Number 1, Vol. VIII (2013).","DOI":"10.2478\/tvsbses-2013-0004"},{"key":"688871","doi-asserted-by":"publisher","unstructured":"Heskestad, G. Fire Plumes, Flame Height, and Air Entrainment. SFPE Handbook of Fire Protection Engineering. Fourth Edition, Section Two, Chapter 2-1. Quincy: National Fire Protection Association, (2008), pp.1-20, ISBN-10: 0-87765-821-8.","DOI":"10.1007\/978-1-4939-2565-0_13"},{"key":"688872","unstructured":"M\u00f3zer, V. On equivalent fire exposure. European Journal of Environmental and Safety Sciences. Vol. 1 (2013), pp.18-23. ISSN 1339-472X (printed), ISSN 1339-4797 (on-line)."},{"key":"688873","unstructured":"Rantuch, P., Ka\u010d\u00edkov\u00e1, D., Nagyp\u00e1l B. Investigation of activation energy of polypropylene composite thermooxidation by model-free methods. European Journal of Environmental and Safety Sciences. Vol. 2 (2014)."},{"key":"688874","doi-asserted-by":"publisher","unstructured":"Martinka, J., Ka\u010d\u00edkov\u00e1, D., Hroncov\u00e1, E., Ladomersk\u00fd, J. Experimental determination of the effect of temperature and oxygen concentration on the production of birch wood main fire emissions. Journal of Thermal Analysis and Calorimetry Vol. 110 (2012).","DOI":"10.1007\/s10973-012-2261-2"},{"key":"688875","unstructured":"Pokorn\u00fd, J. Principles of thermal analysis of Smoke Plume. In proceedings of XVIII year of the international conference Fire Safety 2009 (reviewed journal). Ostrava: V\u0160B-TUO, FBI, SPBI and HZS MSK, (2009). pp.457-467, ISBN 978-80-7385-067-8."},{"key":"688876","doi-asserted-by":"publisher","unstructured":"CFAST. Fire growth and smoke transport Modeling with CFAST. In NIST,\u00a0Fire Research Division, CFAST. [online]. (2014) [cit. 2014-02-27]. Available from WWW: <http: \/www. nist. gov\/el\/fire_research\/cfast. cfm>.","DOI":"10.6028\/nist.tn.1299"}],"container-title":["Advanced Materials Research"],"original-title":[],"link":[{"URL":"https:\/\/www.scientific.net\/AMR.1001.362.pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2021,1,12]],"date-time":"2021-01-12T23:54:05Z","timestamp":1610495645000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.scientific.net\/AMR.1001.362"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2014,8]]},"references-count":12,"URL":"https:\/\/doi.org\/10.4028\/www.scientific.net\/amr.1001.362","relation":{},"ISSN":["1662-8985"],"issn-type":[{"type":"electronic","value":"1662-8985"}],"subject":[],"published":{"date-parts":[[2014,8]]}}}