{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,8]],"date-time":"2026-10-08T09:57:18Z","timestamp":1791453438505,"version":"4.3.3"},"reference-count":20,"publisher":"AACN Publishing","issue":"5","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":[],"published-print":{"date-parts":[[2009,9,1]]},"abstract":"<jats:p>Brain death is manifested by a flaccid, areflexic patient on assessment of brain function with fixed and dilated pupils at midpoint, loss of consciousness, no response to stimulation, loss of brainstem reflexes, and apnea. A lesion or clinical state responsible for the loss of consciousness must be found. An integral part of clinical evaluation of brain death is apnea testing, which indicates complete loss of brainstem function and respiratory drive. Ventilator triggering or overbreathing the ventilator\u2019s set rate may be considered consistent with intrinsic respiratory drive consequent to residual brainstem function. Ventilator autotriggering, however, may potentially occur in a brain-dead patient as a result of interaction between the hyperdynamic cardiovascular system and compliant lung tissue altering airway pressure and flow patterns. Also, chest wall and pre-cordial movements may mimic intrinsic respiratory drive. Ventilator autotriggering may delay determination of brain death, prolong the intensive care unit experience for patients and their families, increase costs, risk loss of donor organs, and confuse staff and family members. A detailed literature review and 3 cases of cardiogenic ventilator autotriggering are presented as examples of this phenomenon and highlight the value of close multidisciplinary clinical evaluation and examination of ventilator pressure and flow waveforms.<\/jats:p>","DOI":"10.4037\/ajcc2009690","type":"journal-article","created":{"date-parts":[[2009,9,1]],"date-time":"2009-09-01T16:03:58Z","timestamp":1251821038000},"page":"496-488","source":"Crossref","is-referenced-by-count":33,"title":["Cardiogenic Oscillation and Ventilator Autotriggering in Brain-Dead Patients: A Case Series"],"prefix":"10.4037","volume":"18","author":[{"given":"Richard","family":"Arbour","sequence":"first","affiliation":[{"name":"Richard Arbour is a clinical nurse specialist for critical care at Albert Einstein Medical Center in Philadelphia, Pennsylvania."}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"2471","reference":[{"key":"2020032809272283000_R1","doi-asserted-by":"crossref","unstructured":"Wijdicks EFM . Practice parameters: determining brain death in adults. Neurology. 1995;45:1003\u20131011.","DOI":"10.1212\/WNL.45.5.1003"},{"key":"2020032809272283000_R2","doi-asserted-by":"crossref","unstructured":"Arbour R . Intracranial hypertension: monitoring and nursing assessment. Crit Care Nurse. 2004;24(5):19\u201334.","DOI":"10.4037\/ccn2004.24.5.19"},{"key":"2020032809272283000_R3","doi-asserted-by":"crossref","unstructured":"Wood KE , Becker BN, McCartney JG, D\u2019Alessandro AM, Coursin DB. Care of the potential organ donor. N Engl J Med. 2004;351(26):2730\u20132739.","DOI":"10.1056\/NEJMra013103"},{"key":"2020032809272283000_R4","doi-asserted-by":"crossref","unstructured":"Wijdicks EFM . The diagnosis of brain death. N Engl J Med. 2001;344(16):1215\u20131221.","DOI":"10.1056\/NEJM200104193441606"},{"key":"2020032809272283000_R5","unstructured":"Op\u2019t Holt TB . Cardiogenic triggering observed in a patient with acute respiratory distress syndrome. Respir Care. 2001;46(10):1054\u20131055."},{"key":"2020032809272283000_R6","doi-asserted-by":"crossref","unstructured":"Arbour R . Clinical management of the organ donor. AACN Clin Issues. 2005;16(4):551\u2013580.","DOI":"10.1097\/00044067-200510000-00011"},{"key":"2020032809272283000_R7","doi-asserted-by":"crossref","unstructured":"Morenski JD , Oro JJ, Tobias JD, Singh A. Determination of death by neurological criteria. J Intensive Care Med. 2003;18(4):211\u2013221.","DOI":"10.1177\/0885066603254359"},{"key":"2020032809272283000_R8","doi-asserted-by":"crossref","unstructured":"Tobin MJ . Advances in mechanical ventilation. N Engl J Med. 2001;344(26):1986\u20131996.","DOI":"10.1056\/NEJM200106283442606"},{"key":"2020032809272283000_R9","unstructured":"Nilsestuen JO , Hargett KD. Using ventilator graphics to identify patient-ventilator asynchrony. Respir Care. 2005; 50(2):202\u2013234."},{"key":"2020032809272283000_R10","unstructured":"Hess DR . Ventilator waveforms and the physiology of pressure support ventilation. Respir Care. 2005;50(2):166\u2013186."},{"key":"2020032809272283000_R11","doi-asserted-by":"crossref","unstructured":"Kondili E , Xirouchaki N, Georgopoulos D. Modulation and treatment of patient-ventilator dyssynchrony. Curr Opin Crit Care. 2007;13:84\u201389.","DOI":"10.1097\/MCC.0b013e328011278d"},{"key":"2020032809272283000_R12","unstructured":"Campbell RS , Branson RD, Johannigman JA, Davis K. Erratic ventilator triggering during neuromuscular blockade. Respir Care. 1997;42(11):1048\u20131056."},{"key":"2020032809272283000_R13","unstructured":"Sager JS , Eiger G, Fuchs BD. Ventilator auto-triggering in a patient with tuberculous bronchopleural fistula. Respir Care. 2003;48(5):519\u2013521."},{"key":"2020032809272283000_R14","doi-asserted-by":"crossref","unstructured":"Al-Khafaji A , Manning HL. Inappropriate ventilator triggering caused by an in-line suction catheter. Intensive Care Med. 2002;28:515\u2013519.","DOI":"10.1007\/s00134-002-1239-0"},{"key":"2020032809272283000_R15","doi-asserted-by":"crossref","unstructured":"Imanaka H , Nishimura M, Takeuchi M, Kimball WR, Yahagi N, Kumon K. Autotriggering caused by cardiogenic oscillation during flow-triggered mechanical ventilation. Crit Care Med. 2000;28(2):402\u2013407.","DOI":"10.1097\/00003246-200002000-00019"},{"key":"2020032809272283000_R16","doi-asserted-by":"crossref","unstructured":"Hill LL , Pearl RG. Flow triggering, pressure triggering and autotriggering during mechanical ventilation. Crit Care Med. 2000;28(2):579\u2013581.","DOI":"10.1097\/00003246-200002000-00054"},{"key":"2020032809272283000_R17","doi-asserted-by":"crossref","unstructured":"Willatts SM , Drummond G. Brainstem death and ventilator trigger settings [case report]. Anaesthesia. 2000;55(7): 676\u2013677.","DOI":"10.1046\/j.1365-2044.2000.01421.x"},{"key":"2020032809272283000_R18","doi-asserted-by":"crossref","unstructured":"Ng HP , Tan K. Brainstem death and ventilator trigger settings. Anaesthesia. 2001;56(1):85\u201386.","DOI":"10.1046\/j.1365-2044.2001.01840-7.x"},{"key":"2020032809272283000_R19","doi-asserted-by":"crossref","unstructured":"Cole RP . Cardiogenic oscillations and apparent ventilation in suspected brain death. Resuscitation. 2003;56(3):335.","DOI":"10.1016\/S0300-9572(02)00429-X"},{"key":"2020032809272283000_R20","doi-asserted-by":"crossref","unstructured":"Wijdicks EFM , Manno EM, Holets SR. Ventilator self-cycling may falsely suggest patient effort during brain death determination. Neurology. 2005;65:774.","DOI":"10.1212\/01.wnl.0000174626.94197.62"}],"container-title":["American Journal of Critical Care"],"original-title":[],"language":"en","link":[{"URL":"http:\/\/aacnjournals.org\/ajcconline\/article-pdf\/18\/5\/496\/93574\/496.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"syndication"},{"URL":"http:\/\/aacnjournals.org\/ajcconline\/article-pdf\/18\/5\/496\/93574\/496.pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2020,5,21]],"date-time":"2020-05-21T22:57:37Z","timestamp":1590101857000},"score":1,"resource":{"primary":{"URL":"https:\/\/aacnjournals.org\/ajcconline\/article\/18\/5\/496\/5764\/Cardiogenic-Oscillation-and-Ventilator"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2009,9,1]]},"references-count":20,"journal-issue":{"issue":"5","published-print":{"date-parts":[[2009,9,1]]}},"URL":"https:\/\/doi.org\/10.4037\/ajcc2009690","relation":{},"ISSN":["1062-3264","1937-710X"],"issn-type":[{"value":"1062-3264","type":"print"},{"value":"1937-710X","type":"electronic"}],"subject":[],"published":{"date-parts":[[2009,9,1]]}}}