{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2022,4,4]],"date-time":"2022-04-04T14:59:58Z","timestamp":1649084398564},"reference-count":17,"publisher":"AACN Publishing","issue":"6","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":[],"published-print":{"date-parts":[[2021,11,1]]},"abstract":"<jats:sec>\n                  <jats:title>Background<\/jats:title>\n                  <jats:p>QT prolongation increases the risk of ventricular arrhythmia and is common among critically ill patients. The gold standard for QT measurement is electrocardiography. Automated measurement of corrected QT (QTc) by cardiac telemetry has been developed, but this method has not been compared with electrocardiography in critically ill patients.<\/jats:p>\n               <\/jats:sec>\n               <jats:sec>\n                  <jats:title>Objective<\/jats:title>\n                  <jats:p>To compare the diagnostic performance of QTc values obtained with cardiac telemetry versus electrocardiography.<\/jats:p>\n               <\/jats:sec>\n               <jats:sec>\n                  <jats:title>Methods<\/jats:title>\n                  <jats:p>This prospective observational study included patients admitted to intensive care who had an electrocardiogram ordered simultaneously with cardiac telemetry. Demographic data and QTc determined by electrocardiography and telemetry were recorded. Bland-Altman analysis was done, and correlation coefficient and receiver operating characteristic (ROC) coefficient were calculated.<\/jats:p>\n               <\/jats:sec>\n               <jats:sec>\n                  <jats:title>Results<\/jats:title>\n                  <jats:p>Fifty-one data points were obtained from 43 patients (65% men). Bland-Altman analysis revealed poor agreement between telemetry and electrocardiography and evidence of fixed and proportional bias. Area under the ROC curve for QTc determined by telemetry was 0.9 (P &amp;lt; .001) for a definition of prolonged QT as QTc \u2265 450 milliseconds in electrocardiography (sensitivity, 88.89%; specificity, 83.33%; cutoff of 464 milliseconds used). Correlation between the 2 methods was only moderate (r = 0.6, P &amp;lt; .001).<\/jats:p>\n               <\/jats:sec>\n               <jats:sec>\n                  <jats:title>Conclusions<\/jats:title>\n                  <jats:p>QTc determination by telemetry has poor agreement and moderate correlation with electrocardiography. However, telemetry has an acceptable area under the curve in ROC analysis with tolerable sensitivity and specificity depending on the cutoff used to define prolonged QT. Cardiac telemetry should be used with caution in critically ill patients.<\/jats:p>\n               <\/jats:sec>","DOI":"10.4037\/ajcc2021568","type":"journal-article","created":{"date-parts":[[2021,11,1]],"date-time":"2021-11-01T02:02:09Z","timestamp":1635732129000},"page":"466-470","source":"Crossref","is-referenced-by-count":0,"title":["Performance of Automated Telemetry in Diagnosing QT Prolongation in Critically Ill Patients"],"prefix":"10.4037","volume":"30","author":[{"given":"Enrique","family":"Calvo-Ayala","sequence":"first","affiliation":[{"name":"Enrique Calvo-Ayala is an attending physician, Division of Pulmonary, Critical Care and Sleep Medicine, William Beaumont Hospital, Royal Oak, Michigan and an assistant professor, Department of Internal Medicine, Oakland University William Beaumont School of Medicine, Rochester, Michigan."}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Vince","family":"Procopio","sequence":"additional","affiliation":[{"name":"Vince Procopio is a critical care pharmacy specialist, Department of Pharmacy, Henry Ford Macomb Hospital, Clinton Township, Michigan."}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Hayk","family":"Papukhyan","sequence":"additional","affiliation":[{"name":"Hayk Papukhyan is a resident physician, Division of Internal Medicine, Henry Ford Macomb Hospital."}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Girish B.","family":"Nair","sequence":"additional","affiliation":[{"name":"Girish B. Nair is an attending physician, Division of Pulmonary, Critical Care and Sleep Medicine, William Beaumont Hospital and an associate professor, Department of Internal Medicine, Oakland University William Beaumont School of Medicine."}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"2471","reference":[{"issue":"6","key":"2021110102020162000_b1-0300466","doi-asserted-by":"crossref","first-page":"1519","DOI":"10.1016\/j.suc.2012.08.018","article-title":"Common complications in the critically ill patient","volume":"92","author":"To","year":"2012","journal-title":"Surg Clin North Am"},{"issue":"6","key":"2021110102020162000_b2-0300466","doi-asserted-by":"crossref","first-page":"e0199028","DOI":"10.1371\/journal.pone.0199028","article-title":"QTc interval prolongation in critically ill patients: prevalence, risk factors and associated medications","volume":"13","author":"Fernandes","year":"2018","journal-title":"PLoS One"},{"issue":"2","key":"2021110102020162000_b3-0300466","doi-asserted-by":"crossref","first-page":"394","DOI":"10.1097\/CCM.0b013e318232db4a","article-title":"High prevalence of corrected QT interval prolongation in acutely ill patients is associated with mortality: results of the QT in Practice (QTIP) Study","volume":"40","author":"Pickham","year":"2012","journal-title":"Crit Care Med"},{"issue":"9","key":"2021110102020162000_b4-0300466","doi-asserted-by":"crossref","first-page":"934","DOI":"10.1016\/j.jacc.2010.01.001","article-title":"Prevention of torsade de pointes in hospital settings: a scientific statement from the American Heart Association and the American College of Cardiology Foundation","volume":"55","author":"Drew","year":"2010","journal-title":"J Am Coll Cardiol"},{"issue":"1","key":"2021110102020162000_b5-0300466","doi-asserted-by":"crossref","first-page":"3","DOI":"10.1016\/S1056-8719(03)00008-X","article-title":"How to correct the QT interval for the effects of heart rate in clinical studies","volume":"48","author":"Davey","year":"2002","journal-title":"J Pharmacol Toxicol Methods"},{"issue":"suppl 4","key":"2021110102020162000_b6-0300466","doi-asserted-by":"crossref","first-page":"S123","DOI":"10.1016\/j.jelectrocard.2006.05.018","article-title":"An algorithm for continuous real-time QT interval monitoring","volume":"39","author":"Helfenbein","year":"2006","journal-title":"J Electrocardiol"},{"issue":"suppl 1","key":"2021110102020162000_b7-0300466","doi-asserted-by":"crossref","first-page":"S3","DOI":"10.1111\/j.1542-474X.2008.00258.x","article-title":"Philips QT interval measurement algorithms for diagnostic, ambulatory, and patient monitoring ECG applications","volume":"14","author":"Zhou","year":"2009","journal-title":"Ann Noninvasive Electrocardiol"},{"issue":"2","key":"2021110102020162000_b8-0300466","doi-asserted-by":"crossref","first-page":"377","DOI":"10.1016\/j.jbi.2008.08.010","article-title":"Research electronic data capture (REDCap)\u2013a metadata-driven methodology and workflow process for providing translational research informatics support","volume":"42","author":"Harris","year":"2009","journal-title":"J Biomed Inform"},{"key":"2021110102020162000_b9-0300466","doi-asserted-by":"crossref","first-page":"103208","DOI":"10.1016\/j.jbi.2019.103208","article-title":"The REDCap consortium: building an international community of software platform partners","volume":"95","author":"Harris","year":"2019","journal-title":"J Biomed Inform"},{"key":"2021110102020162000_b10-0300466","volume-title":"Designing Clinical Research","author":"Hulley","year":"2007","edition":"3rd"},{"issue":"11","key":"2021110102020162000_b11-0300466","doi-asserted-by":"crossref","first-page":"982","DOI":"10.1016\/j.jacc.2008.12.014","article-title":"AHA\/ACCF\/HRS recommendations for the standardization and interpretation of the electrocardiogram: part IV: the ST segment, T and U waves, and the QT interval: a scientific statement from the American Heart Association Electrocardiography and Arrhythmias Committee, Council on Clinical Cardiology; the American College of Cardiology Foundation; and the Heart Rhythm Society. Endorsed by the International Society for Computerized Electrocardiology","volume":"53","author":"Rautaharju","year":"2009","journal-title":"J Am Coll Cardiol"},{"issue":"5","key":"2021110102020162000_b12-0300466","doi-asserted-by":"crossref","first-page":"1047","DOI":"10.1016\/j.jacc.2006.06.033","article-title":"Corrected QT variability in serial electrocardiograms in long QT syndrome: the importance of the maximum corrected QT for risk stratification","volume":"48","author":"Goldenberg","year":"2006","journal-title":"J Am Coll Cardiol"},{"issue":"2","key":"2021110102020162000_b13-0300466","doi-asserted-by":"crossref","first-page":"135","DOI":"10.1177\/096228029900800204","article-title":"Measuring agreement in method comparison studies","volume":"8","author":"Bland","year":"1999","journal-title":"Stat Methods Med Res"},{"issue":"2","key":"2021110102020162000_b14-0300466","doi-asserted-by":"crossref","first-page":"141","DOI":"10.11613\/BM.2015.015","article-title":"Understanding Bland Altman analysis","volume":"25","author":"Giavarina","year":"2015","journal-title":"Biochem Med (Zagreb)"},{"issue":"5","key":"2021110102020162000_b15-0300466","doi-asserted-by":"crossref","first-page":"346","DOI":"10.4037\/ajcc1998.7.5.346","article-title":"Comparison of 2 methods of measuring the QT interval","volume":"7","author":"Rimmer","year":"1998","journal-title":"Am J Crit Care"},{"issue":"2","key":"2021110102020162000_b16-0300466","doi-asserted-by":"crossref","first-page":"255","DOI":"10.1097\/00000542-200602000-00009","article-title":"QT interval measurement: evaluation of automatic QTc measurement and new simple method to calculate and interpret corrected QT interval","volume":"104","author":"Charbit","year":"2006","journal-title":"Anesthesiology"},{"key":"2021110102020162000_b17-0300466","doi-asserted-by":"crossref","first-page":"244","DOI":"10.1016\/j.jcrc.2019.09.014","article-title":"The incidence, predictors and outcomes of QTc prolongation in critically ill patients","volume":"54","author":"Russell","year":"2019","journal-title":"J Crit Care"}],"container-title":["American Journal of Critical Care"],"original-title":[],"language":"en","link":[{"URL":"http:\/\/aacnjournals.org\/ajcconline\/article-pdf\/30\/6\/466\/138847\/466.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"syndication"},{"URL":"http:\/\/aacnjournals.org\/ajcconline\/article-pdf\/30\/6\/466\/138847\/466.pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2021,11,1]],"date-time":"2021-11-01T02:02:21Z","timestamp":1635732141000},"score":1,"resource":{"primary":{"URL":"https:\/\/aacnjournals.org\/ajcconline\/article\/30\/6\/466\/31590\/Performance-of-Automated-Telemetry-in-Diagnosing"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2021,11,1]]},"references-count":17,"journal-issue":{"issue":"6","published-print":{"date-parts":[[2021,11,1]]}},"URL":"https:\/\/doi.org\/10.4037\/ajcc2021568","relation":{},"ISSN":["1062-3264","1937-710X"],"issn-type":[{"value":"1062-3264","type":"print"},{"value":"1937-710X","type":"electronic"}],"subject":[],"published":{"date-parts":[[2021,11,1]]}}}