{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,22]],"date-time":"2026-09-22T01:10:36Z","timestamp":1790039436633,"version":"4.0.1"},"reference-count":47,"publisher":"AACN Publishing","issue":"2","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":[],"published-print":{"date-parts":[[2017,4,1]]},"abstract":"<jats:p>Fluid boluses are often administered with the aim of improving tissue hypoperfusion in shock. However, only approximately 50% of patients respond to fluid administration with a clinically significant increase in stroke volume. Fluid overload can exacerbate pulmonary edema, precipitate respiratory failure, and prolong mechanical ventilation. Therefore, it is important to predict which hemodynamically unstable patients will increase their stroke volume in response to fluid administration, thereby avoiding deleterious effects. Passive leg-raising (lowering the head and upper torso from a 45\u00b0 angle to lying supine [flat] while simultaneously raising the legs to a 45\u00b0 angle) is a transient, reversible autotransfusion that simulates a fluid bolus and is performed to predict a response to fluid administration. The article reviews the accuracy, physiological effects, and factors affecting the response to passive-leg raising to predict fluid responsiveness in critically ill patients.<\/jats:p>","DOI":"10.4037\/ccn2017205","type":"journal-article","created":{"date-parts":[[2017,4,1]],"date-time":"2017-04-01T04:17:37Z","timestamp":1491020257000},"page":"32-47","source":"Crossref","is-referenced-by-count":24,"title":["Passive Leg-Raising and Prediction of Fluid Responsiveness: Systematic Review"],"prefix":"10.4037","volume":"37","author":[{"given":"Joya D.","family":"Pickett","sequence":"first","affiliation":[{"name":"Joya D. Pickett completed her doctoral degree at the University of Washington, School of Nursing, and practices as a critical care clinical nurse specialist at Swedish Medical Center in Seattle, Washington."}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Elizabeth","family":"Bridges","sequence":"additional","affiliation":[{"name":"Elizabeth Bridges is an associate professor at the University of Washington School of Nursing and the clinical nurse researcher at the University of Washington Medical Center, Seattle, Washington."}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Patricia A.","family":"Kritek","sequence":"additional","affiliation":[{"name":"Patricia (Trish) A. Kritek is the medical director of Critical Care at the University of Washington Medical Center."}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"JoAnne D.","family":"Whitney","sequence":"additional","affiliation":[{"name":"JoAnne D. Whitney is a professor of nursing at the University of Washington, School of Nursing, and a nurse scientist at Harborview Medical Center, Seattle, Washington."}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"2471","reference":[{"issue":"2","key":"2019112601054060900_b1-0370032","doi-asserted-by":"crossref","first-page":"580","DOI":"10.1097\/CCM.0b013e31827e83af","article-title":"Surviving sepsis campaign: international guidelines for managment of severe sepsis and septic shock: 2012","volume":"41","author":"Dellinger","year":"2013","journal-title":"Crit Care Med"},{"issue":"9","key":"2019112601054060900_b2-0370032","doi-asserted-by":"crossref","first-page":"2642","DOI":"10.1097\/CCM.0b013e3181a590da","article-title":"Dynamic changes in arterial waveform derived variables and fluid responsiveness in mechanically ventilated patients: a systematic review of the literature","volume":"37","author":"Marik","year":"2009","journal-title":"Crit Care Med"},{"issue":"1","key":"2019112601054060900_b3-0370032","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1186\/2110-5820-1-1","article-title":"Hemodynamic parameters to guide fluid therapy","volume":"1","author":"Marik","year":"2011","journal-title":"Ann Intensive Care"},{"issue":"12","key":"2019112601054060900_b4-0370032","doi-asserted-by":"crossref","first-page":"1643","DOI":"10.1007\/s00134-005-2801-3","article-title":"Fluid balance and weaning outcomes","volume":"31","author":"Upadya","year":"2005","journal-title":"Intensive Care Med"},{"issue":"2","key":"2019112601054060900_b5-0370032","doi-asserted-by":"crossref","first-page":"259","DOI":"10.1097\/CCM.0b013e3181feeb15","article-title":"Fluid resuscitation in septic shock: a positive fluid balance and elevated central venous pressure are associated with increased mortality","volume":"39","author":"Boyd","year":"2011","journal-title":"Crit Care Med"},{"issue":"5","key":"2019112601054060900_b6-0370032","doi-asserted-by":"crossref","first-page":"329","DOI":"10.1177\/0885066609340640","article-title":"Techniques for assessment of intravascular volume in critically ill patients","volume":"24","author":"Marik","year":"2009","journal-title":"J Intensive Care Med"},{"issue":"9","key":"2019112601054060900_b7-0370032","doi-asserted-by":"crossref","first-page":"1475","DOI":"10.1007\/s00134-010-1929-y","article-title":"Diagnostic accuracy of passive leg raising for prediction of fluid responsiveness in adults: systematic review and meta-analysis of clinical studies","volume":"36","author":"Cavallaro","year":"2010","journal-title":"Intensive Care Med"},{"issue":"5","key":"2019112601054060900_b8-0370032","doi-asserted-by":"crossref","first-page":"67","DOI":"10.1016\/j.annfar.2012.01.032","article-title":"Brachial cuff measurements of blood pressure during passive leg raising for fluid responsiveness prediction","volume":"31","author":"Lakhal","year":"2012","journal-title":"Ann Fr Anest Reanim"},{"issue":"6","key":"2019112601054060900_b9-0370032","doi-asserted-by":"crossref","first-page":"940","DOI":"10.1007\/s00134-010-1755-2","article-title":"Central venous pressure measurements improve the accuracy of leg raising-induced change in pulse pressure to predict fluid responsiveness","volume":"36","author":"Lakhal","year":"2010","journal-title":"Intensive Care Med"},{"issue":"1","key":"2019112601054060900_b10-0370032","doi-asserted-by":"crossref","first-page":"152","DOI":"10.1097\/CCM.0b013e31822f08d7","article-title":"Passive leg-raising and end-expriatory occlusion tests perform better than pulse pressure variation in patients with low respiratory system compliance","volume":"40","author":"Monnet","year":"2012","journal-title":"Crit Care Med"},{"issue":"11","key":"2019112601054060900_b11-0370032","doi-asserted-by":"crossref","first-page":"1875","DOI":"10.1007\/s00134-010-1990-6","article-title":"Fluid responsiveness predicted by noninvasive bioreactance-based passive leg raise test","volume":"36","author":"Benomar","year":"2010","journal-title":"Intensive Care Med"},{"issue":"6","key":"2019112601054060900_b12-0370032","doi-asserted-by":"crossref","first-page":"R195","DOI":"10.1186\/cc8195","article-title":"Changes in stroke volume induced by passive leg raising in spontaneous breathing patients: comparison between echocardiography and Vigileo\/FloTrac device","volume":"13","author":"Biais","year":"2009","journal-title":"Crit Care"},{"key":"2019112601054060900_b13-0370032","unstructured":"Surviving Sepsis Campaign. Updated bundles in response to new evidence. http:\/\/www.survivingsepsis.org\/sitecollectiondocuments\/ssc_bundle.pdf."},{"issue":"4","key":"2019112601054060900_b14-0370032","first-page":"123","article-title":"Functional hemodynamic monitoring and dynamic indices of fluid responsiveness","volume":"74","author":"Cavallaro","year":"2008","journal-title":"Minerva Anestesiol"},{"issue":"1","key":"2019112601054060900_b15-0370032","first-page":"1","article-title":"Clinical applicability of functional hemodynamic monitoring","volume":"35","author":"Garcia","year":"2011","journal-title":"Ann Intensive Care"},{"issue":"5","key":"2019112601054060900_b16-0370032","doi-asserted-by":"crossref","first-page":"1402","DOI":"10.1097\/01.CCM.0000215453.11735.06","article-title":"Passive leg raising predicts fluid responsiveness in the critically ill","volume":"34","author":"Monnet","year":"2006","journal-title":"Crit Care Med"},{"issue":"3","key":"2019112601054060900_b17-0370032","doi-asserted-by":"crossref","first-page":"334","DOI":"10.1097\/MCC.0b013e3282fd6e1e","article-title":"Prediction of volume responsiveness in critically ill patients with spontaneous breathing activity","volume":"14","author":"Teboul","year":"2008","journal-title":"Curr Opin Crit Care"},{"issue":"1","key":"2019112601054060900_b18-0370032","doi-asserted-by":"crossref","first-page":"85","DOI":"10.1007\/s00134-008-1293-3","article-title":"Passive leg raising for predicting fluid responsiveness: importance of the postural change","volume":"35","author":"Jabot","year":"2009","journal-title":"Intensive Care Med"},{"issue":"4","key":"2019112601054060900_b19-0370032","doi-asserted-by":"crossref","first-page":"1245","DOI":"10.1378\/chest.121.4.1245","article-title":"Changes in BP induced by passive leg raising predict response to fluid loading in critically ill patients","volume":"121","author":"Boulain","year":"2002","journal-title":"Chest"},{"issue":"4","key":"2019112601054060900_b20-0370032","doi-asserted-by":"crossref","first-page":"659","DOI":"10.1007\/s00134-008-0994-y","article-title":"Passive leg raising","volume":"34","author":"Monnet","year":"2008","journal-title":"Intensive Care Med"},{"issue":"5","key":"2019112601054060900_b21-0370032","doi-asserted-by":"crossref","first-page":"R132","DOI":"10.1186\/cc5044","article-title":"Changes in aortic blood flow induced by passive leg raising predict fluid responsiveness in critically ill patients","volume":"10","author":"Lafanechere","year":"2006","journal-title":"Crit Care"},{"issue":"3","key":"2019112601054060900_b22-0370032","doi-asserted-by":"crossref","first-page":"819","DOI":"10.1097\/CCM.0b013e3181c8fe7a","article-title":"Passive leg raising is predictive of fluid responsiveness in spontaneously breathing patients with severe sepsis or acute pancreatitis","volume":"38","author":"Preau","year":"2010","journal-title":"Crit Care Med"},{"issue":"3","key":"2019112601054060900_b23-0370032","doi-asserted-by":"crossref","first-page":"745","DOI":"10.1053\/j.jvca.2013.12.025","article-title":"Defining fluid responsiveness: a guide to patient-tailored volume titration","volume":"28","author":"Cherpanath","year":"2014","journal-title":"J Cardiothorac Vasc Anesth"},{"issue":"7","key":"2019112601054060900_b24-0370032","doi-asserted-by":"crossref","first-page":"1125","DOI":"10.1007\/s00134-007-0646-7","article-title":"Echocardiographic prediction of volume responsiveness in critically ill patients with spontaneous breathing activity","volume":"33","author":"Lamia","year":"2007","journal-title":"Intensive Care Med"},{"issue":"4","key":"2019112601054060900_b25-0370032","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1186\/cc7955","article-title":"Non-invasive stroke volume measurement and passive leg raising predict volume responsiveness in medical ICU patients: an observational cohort study","volume":"13","author":"Thiel","year":"2009","journal-title":"Crit Care"},{"issue":"1","key":"2019112601054060900_b26-0370032","doi-asserted-by":"crossref","first-page":"1133","DOI":"10.1007\/s00134-007-0642-y","article-title":"Diagnosis of central hypovolemia by using passive leg raising","volume":"33","author":"Maizel","year":"2007","journal-title":"Intensive Care Med"},{"issue":"3","key":"2019112601054060900_b27-0370032","doi-asserted-by":"crossref","first-page":"951","DOI":"10.1097\/CCM.0b013e3181968fe1","article-title":"Predicting volume responsiveness by using end-expiratory occlusion in mechanically ventilated intensive care unit patients","volume":"37","author":"Monnet","year":"2009","journal-title":"Crit Care Med"},{"issue":"8","key":"2019112601054060900_b28-0370032","doi-asserted-by":"crossref","first-page":"1445","DOI":"10.1007\/s00134-010-1900-y","article-title":"Passive leg raising: keep it easy!","volume":"36","author":"Monnet","year":"2010","journal-title":"Intensive Care Med"},{"issue":"12","key":"2019112601054060900_b29-0370032","doi-asserted-by":"crossref","first-page":"530","DOI":"10.1007\/s12471-013-0487-7","article-title":"Basic concepts of fluid responsiveness","volume":"21","author":"Cherpanath","year":"2013","journal-title":"Neth Heart J"},{"issue":"2","key":"2019112601054060900_b30-0370032","doi-asserted-by":"crossref","first-page":"364","DOI":"10.1378\/chest.12-1274","article-title":"Use of bioreactance and carotid Doppler to determine volume responsiveness and blood flow redistribution following passive leg raising in hemodynamically unstable patients","volume":"143","author":"Marik","year":"2013","journal-title":"Chest"},{"issue":"2","key":"2019112601054060900_b31-0370032","doi-asserted-by":"crossref","first-page":"R37","DOI":"10.1186\/cc6822","article-title":"Ability of pleth variability index to detect hemodynamic changes induced by passive leg raising in spontaneously breathing volunteers","volume":"12","author":"Keller","year":"2008","journal-title":"Crit Care"},{"issue":"2","key":"2019112601054060900_b32-0370032","doi-asserted-by":"crossref","first-page":"164","DOI":"10.1186\/cc1882","article-title":"Influence of passive leg elevation on the right ventricular function in anaesthetized coronary patients","volume":"7","author":"Bertolissi","year":"2003","journal-title":"Crit Care"},{"issue":"2","key":"2019112601054060900_b33-0370032","doi-asserted-by":"crossref","first-page":"248","DOI":"10.1007\/s00134-014-3576-1","article-title":"Volume expansion in the first 4 days of shock: a prospective multicenter study in 19 French intensive care units","volume":"41","author":"Boulain","year":"2015","journal-title":"Intensive Care Med"},{"issue":"1","key":"2019112601054060900_b34-0370032","doi-asserted-by":"crossref","first-page":"64","DOI":"10.1097\/01.CCM.0000249851.94101.4F","article-title":"Cardiac filling pressures are not appropriate to predict hemodynamic response to volume challenge","volume":"35","author":"Osman","year":"2007","journal-title":"Crit Care Med"},{"issue":"2","key":"2019112601054060900_b35-0370032","doi-asserted-by":"crossref","first-page":"105","DOI":"10.1097\/01.JCN.0000305078.36152.94","article-title":"Arterial pressure-based stroke volume and functional hemodynamic monitoring","volume":"23","author":"Bridges","year":"2008","journal-title":"J Cardiovasc Nurs"},{"issue":"3","key":"2019112601054060900_b36-0370032","doi-asserted-by":"crossref","first-page":"691","DOI":"10.1097\/01.CCM.0000114996.68110.C9","article-title":"Pulmonary artery occlusion pressure and central venous pressure fail to predict ventricular filling volume, cardiac performance, or the response to volume infusion in normal subjects","volume":"32","author":"Kumar","year":"2004","journal-title":"Crit Care Med"},{"issue":"1","key":"2019112601054060900_b37-0370032","doi-asserted-by":"crossref","first-page":"172","DOI":"10.1378\/chest.07-2331","article-title":"Does the central venous pressure predict fluid responsiveness? A systematic review of the literature and the tale of seven mares","volume":"134","author":"Marik","year":"2008","journal-title":"Chest"},{"issue":"3","key":"2019112601054060900_b38-0370032","doi-asserted-by":"crossref","first-page":"256","DOI":"10.1097\/MCC.0b013e3283532b73","article-title":"Heart lung interactions during mechanical ventilation","volume":"18","author":"Pinsky","year":"2012","journal-title":"Curr Opin Crit Care"},{"issue":"4","key":"2019112601054060900_b39-0370032","doi-asserted-by":"crossref","first-page":"517","DOI":"10.1007\/s00134-005-2586-4","article-title":"Pulse pressure variations to predict fluid responsiveness: influence of tidal volume","volume":"31","author":"DeBacker","year":"2005","journal-title":"Intensive Care Med"},{"issue":"2","key":"2019112601054060900_b40-0370032","doi-asserted-by":"crossref","first-page":"58","DOI":"10.4037\/ccn2014411","article-title":"Choosing the best evidence to guide clinical practice: application of AACN levels of evidence","volume":"34","author":"Peterson","year":"2014","journal-title":"Critical Care Nurse"},{"key":"2019112601054060900_b41-0370032","doi-asserted-by":"crossref","first-page":"18","DOI":"10.1186\/s13054-014-0708-5","article-title":"Passive leg raising: five rules, not a drop of fluid!","volume":"19","author":"Monnet","year":"2015","journal-title":"Crit Care"},{"issue":"1","key":"2019112601054060900_b42-0370032","first-page":"1","article-title":"Dynamic arterial elastance to predict arterial pressure response to volume loading in preload-dependent patients","volume":"15","author":"Garcia","year":"2011","journal-title":"Crit Care"},{"key":"2019112601054060900_b43-0370032","first-page":"1","article-title":"Can passive leg raising be used to guide fluid administration?","volume":"10","author":"DeBacker","year":"2006","journal-title":"Crit Care"},{"issue":"4","key":"2019112601054060900_b44-0370032","doi-asserted-by":"crossref","first-page":"689","DOI":"10.1097\/CCM.0b013e318206d2a3","article-title":"Norepinephrine increases cardiac preload and reduces preload dependency assessed by passive leg raising in septic shock","volume":"39","author":"Monnet","year":"2011","journal-title":"Crit Care Med"},{"issue":"9","key":"2019112601054060900_b45-0370032","doi-asserted-by":"crossref","first-page":"1824","DOI":"10.1097\/CCM.0b013e3181eb3c21","article-title":"The passive-leg raising maneuver cannont accurately predict fluid responsiveness in patients with intra-abdominal pressure","volume":"38","author":"Mahjoub","year":"2010","journal-title":"Crit Care Med"},{"issue":"4","key":"2019112601054060900_b46-0370032","doi-asserted-by":"crossref","first-page":"393","DOI":"10.1055\/s-0034-1389089","article-title":"Passive leg raising during pregnancy","volume":"32","author":"Marques","year":"2015","journal-title":"Am J Perinatol"},{"issue":"2","key":"2019112601054060900_b47-0370032","doi-asserted-by":"crossref","first-page":"163","DOI":"10.1007\/s10877-012-9409-2","article-title":"Comparing hemodynamic effects with three different measurement devices, of two methods of external leg compression versus passive leg raising in patients after cardiac surgery","volume":"27","author":"Helmi","year":"2013","journal-title":"J Clin Monit Comput"}],"container-title":["Critical Care Nurse"],"original-title":[],"language":"en","link":[{"URL":"http:\/\/aacnjournals.org\/ccnonline\/article-pdf\/37\/2\/32\/116206\/32.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"syndication"},{"URL":"http:\/\/aacnjournals.org\/ccnonline\/article-pdf\/37\/2\/32\/116206\/32.pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2019,11,26]],"date-time":"2019-11-26T01:07:04Z","timestamp":1574730424000},"score":1,"resource":{"primary":{"URL":"https:\/\/aacnjournals.org\/ccnonline\/article\/37\/2\/32\/3795\/Passive-LegRaising-and-Prediction-of-Fluid"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2017,4,1]]},"references-count":47,"journal-issue":{"issue":"2","published-print":{"date-parts":[[2017,4,1]]}},"URL":"https:\/\/doi.org\/10.4037\/ccn2017205","relation":{},"ISSN":["0279-5442","1940-8250"],"issn-type":[{"value":"0279-5442","type":"print"},{"value":"1940-8250","type":"electronic"}],"subject":[],"published":{"date-parts":[[2017,4,1]]}}}