{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2023,10,24]],"date-time":"2023-10-24T16:25:47Z","timestamp":1698164747739},"reference-count":25,"publisher":"AACN Publishing","issue":"1","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":[],"published-print":{"date-parts":[[2018,2,1]]},"abstract":"<jats:p>Transcatheter pulmonary valve replacement is now a feasible alternative to surgical pulmonary valve replacement in children and adults with dysfunctional right ventricular outflow conduits. Currently, 2 types of valves can be used for this application. This article provides an overview of the procedure and how it is performed, indications and contraindications for transcatheter pulmonary valve replacement, and short- and long-term outcomes. Nursing considerations mainly focus on educating patients, preventing bleeding and infection, monitoring renal function, and preventing injury to the catheter insertion site. This article enhances the knowledge of nurses working in cardiac catheterization laboratories and post-procedure recovery and cardiac units so that the nurses can anticipate interventions and understand the management of patients who have transcatheter pulmonary valve replacement.<\/jats:p>","DOI":"10.4037\/ccn2018581","type":"journal-article","created":{"date-parts":[[2018,2,1]],"date-time":"2018-02-01T09:10:12Z","timestamp":1517476212000},"page":"30-36","source":"Crossref","is-referenced-by-count":1,"title":["Transcatheter Pulmonary Valve Replacement in Patients With Congenital Heart Disease"],"prefix":"10.4037","volume":"38","author":[{"given":"Shantelle","family":"Bartra","sequence":"first","affiliation":[{"name":"Shantelle Bartra is a pediatric nurse practitioner and coordinator in the cardiac catheterization laboratory, Congenital Heart Center, University of Florida Health, Shands Hospital, Gainesville, Florida."}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"2471","reference":[{"issue":"18","key":"2019112519063258000_b1-0380030","doi-asserted-by":"crossref","first-page":"1455","DOI":"10.1136\/heartjnl-2016-310776","article-title":"Early outcomes in patients undergoing transcatheter versus surgical pulmonary valve replacement [published online ahead of print March 28, 2017]","volume":"103","author":"Steinberg","year":"2017","journal-title":"Heart"},{"issue":"1","key":"2019112519063258000_b2-0380030","doi-asserted-by":"publisher","first-page":"121","DOI":"10.1016\/j.amjcard.2015.10.011","article-title":"Cost-comparison of transcatheter and operative pulmonary valve replacement (from the Pediatric Health Information Systems Database)","volume":"117","author":"O\u2019Byrne","year":"2016","journal-title":"Am J Cardiol"},{"key":"2019112519063258000_b3-0380030","volume-title":"Moss and Adams\u2019 Heart Disease in Infants, Children, and Adolescents: Including the Fetus and Young Adult","author":"Allen","year":"2016","edition":"9th"},{"issue":"1","key":"2019112519063258000_b4-0380030","doi-asserted-by":"crossref","first-page":"5","DOI":"10.1007\/s40119-012-0005-9","article-title":"Transcatheter pulmonary valve replacement","volume":"1","author":"Ghawi","year":"2012","journal-title":"Cardiol Ther"},{"issue":"7","key":"2019112519063258000_b5-0380030","doi-asserted-by":"crossref","first-page":"813","DOI":"10.1161\/01.CIR.102.7.813","article-title":"Transcatheter implantation of a bovine valve in pulmonary position: a lamb study","volume":"102","author":"Bonhoeffer","year":"2000","journal-title":"Circulation"},{"issue":"9239","key":"2019112519063258000_b6-0380030","doi-asserted-by":"crossref","first-page":"1403","DOI":"10.1016\/S0140-6736(00)02844-0","article-title":"Percutaneous replacement of pulmonary valve in a right-ventricle to pulmonary-artery prosthetic conduit with valve dysfunction","volume":"356","author":"Bonhoeffer","year":"2000","journal-title":"Lancet"},{"issue":"1","key":"2019112519063258000_b7-0380030","doi-asserted-by":"crossref","first-page":"53","DOI":"10.4103\/0974-2069.93713","article-title":"Percutaneous pulmonary valve implantation","volume":"5","author":"Khambadkone","year":"2012","journal-title":"Ann Pediatr Cardiol"},{"issue":"5","key":"2019112519063258000_b8-0380030","doi-asserted-by":"crossref","first-page":"507","DOI":"10.1161\/CIRCULATIONAHA.109.921692","article-title":"Short- and medium-term outcomes after transcatheter pulmonary valve placement in the expanded multicenter US melody valve trial","volume":"122","author":"McElhinney","year":"2010","journal-title":"Circulation"},{"issue":"6","key":"2019112519063258000_b9-0380030","doi-asserted-by":"crossref","first-page":"602","DOI":"10.1161\/CIRCINTERVENTIONS.111.965616","article-title":"Stent fracture, valve dysfunction, and right ventricular outflow tract reintervention after transcatheter pulmonary valve implantation: patient-related and procedural risk factors in the US Melody Valve Trial","volume":"4","author":"McElhinney","year":"2011","journal-title":"Circ Cardiovasc Interv"},{"issue":"10","key":"2019112519063258000_b10-0380030","doi-asserted-by":"crossref","first-page":"1260","DOI":"10.1093\/eurheartj\/ehq520","article-title":"Percutaneous pulmonary valve implantation: two-centre experience with more than 100 patients","volume":"32","author":"Eicken","year":"2011","journal-title":"Eur Heart J"},{"issue":"22","key":"2019112519063258000_b11-0380030","doi-asserted-by":"crossref","first-page":"1960","DOI":"10.1161\/CIRCULATIONAHA.114.013588","article-title":"Clinical and hemodynamic outcomes up to 7 years after transcatheter pulmonary valve replacement in the US melody valve investigational device exemption trial","volume":"131","author":"Cheatham","year":"2015","journal-title":"Circulation"},{"issue":"11","key":"2019112519063258000_b12-0380030","doi-asserted-by":"crossref","first-page":"1254","DOI":"10.1016\/j.jcin.2014.08.002","article-title":"One-year follow-up of the Melody transcatheter pulmonary valve multicenter post-approval study","volume":"7","author":"Armstrong","year":"2014","journal-title":"JACC Cardiovasc Interv"},{"issue":"2","key":"2019112519063258000_b13-0380030","doi-asserted-by":"crossref","first-page":"310","DOI":"10.1002\/ccd.24518","article-title":"Melody transcatheter pulmonary valve implantation: results from the registry of the Italian Society of Pediatric Cardiology","volume":"81","author":"Butera","year":"2013","journal-title":"Catheter Cardiovasc Interv"},{"issue":"18","key":"2019112519063258000_b14-0380030","doi-asserted-by":"crossref","first-page":"1722","DOI":"10.1016\/j.jacc.2009.06.034","article-title":"Implantation of the melody transcatheter pulmonary valve in patients with a dysfunctional right ventricular outflow tract conduit: early results from the US clinical trial","volume":"54","author":"Zahn","year":"2009","journal-title":"J Am Coll Cardiol"},{"issue":"15","key":"2019112519063258000_b15-0380030","doi-asserted-by":"crossref","first-page":"1964","DOI":"10.1161\/CIRCULATIONAHA.107.735779","article-title":"Percutaneous pulmonary valve implantation: impact of evolving technology and learning curve on clinical outcome","volume":"117","author":"Lurz","year":"2008","journal-title":"Circulation"},{"key":"2019112519063258000_b16-0380030","unstructured":"Edwards Lifesciences. Edwards SAPIEN Transcather Heart Valve: Pulmonic. http:\/\/www.edwards.com\/eu\/products\/transcathetervalves\/pages\/pulmonic.aspx. Accessed October 16, 2017."},{"issue":"5","key":"2019112519063258000_b17-0380030","doi-asserted-by":"crossref","first-page":"659","DOI":"10.1002\/ccd.20753","article-title":"Percutaneous replacement of pulmonary valve using the Edwards-Cribier percutaneous heart valve: first report in a human patient","volume":"67","author":"Garay","year":"2006","journal-title":"Catheter Cardiovasc Interv"},{"issue":"21","key":"2019112519063258000_b18-0380030","doi-asserted-by":"crossref","first-page":"2248","DOI":"10.1016\/j.jacc.2011.07.040","article-title":"Percutaneous implantation of the Edwards SAPIEN transcatheter heart valve for conduit failure in the pulmonary position: early phase 1 results from an international multicenter clinical trial","volume":"58","author":"Kenny","year":"2011","journal-title":"J Am Coll Cardiol"},{"key":"2019112519063258000_b19-0380030","doi-asserted-by":"crossref","first-page":"916","DOI":"10.1016\/j.ijcard.2016.07.120","article-title":"Defining and refining indications for transcatheter pulmonary valve replacement in patients with repaired tetralogy of Fallot: contributions from anatomical and functional imaging","volume":"221","author":"Tretter","year":"2016","journal-title":"Int J Cardiol"},{"key":"2019112519063258000_b20-0380030","unstructured":"Medtronic Inc. Transcatheter Pulmonary Valve (TPV) Therapy. http:\/\/www.medtronic.com\/melody\/downloads\/ensemble-ii-product-brochure.pdf. Accessed October 31, 2017."},{"issue":"23","key":"2019112519063258000_b21-0380030","doi-asserted-by":"crossref","first-page":"e143","DOI":"10.1016\/j.jacc.2008.10.001","article-title":"ACC\/AHA 2008 guidelines for the management of adults with congenital heart disease: a report of the American College of Cardiology\/American Heart Association Task Force on Practice Guidelines (Writing Committee to Develop Guidelines on the Management of Adults With Congenital Heart Disease). Developed in collaboration with the American Society of Echocardiography, Heart Rhythm Society, International Society for Adult Congenital Heart Disease, Society for Cardiovascular Angiography and Interventions, and Society of Thoracic Surgeons","volume":"52","author":"Warnes","year":"2008","journal-title":"J Am Coll Cardiol"},{"issue":"9","key":"2019112519063258000_b22-0380030","doi-asserted-by":"crossref","first-page":"1060","DOI":"10.1016\/j.jcin.2014.04.013","article-title":"Radiation dose benchmarks during cardiac catheterization for congenital heart disease in the United States","volume":"7","author":"Ghelani","year":"2014","journal-title":"JACC Cardiovasc Interv"},{"key":"2019112519063258000_b23-0380030","unstructured":"Educational Modules, Image Gently: Enhancing Radiation Protection in Pediatric Fluoroscopy. http:\/\/www.imagegently.org\/Procedures\/Fluoroscopy\/Pause-and-Pulse-Resources. Accessed October 31, 2017."},{"key":"2019112519063258000_b24-0380030","unstructured":"International Atomic Energy Agency. Radiation protection of patients (RPOP): interventional cardiology. https:\/\/rpop.iaea.org\/RPOP\/RPoP\/Content\/InformationFor\/HealthProfessionals\/5_InterventionalCardiology\/index.htm. Accessed October 18, 2017."},{"issue":"6","key":"2019112519063258000_b25-0380030","first-page":"E82","article-title":"Transcatheter pulmonary valve implantation in patients with right ventricular outflow tract dysfunction: early and mid-term results","volume":"27","author":"Biernacka","year":"2015","journal-title":"J Invasive Cardiol"}],"container-title":["Critical Care Nurse"],"original-title":[],"language":"en","link":[{"URL":"http:\/\/aacnjournals.org\/ccnonline\/article-pdf\/38\/1\/30\/115780\/30.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"syndication"},{"URL":"http:\/\/aacnjournals.org\/ccnonline\/article-pdf\/38\/1\/30\/115780\/30.pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2019,11,26]],"date-time":"2019-11-26T00:12:27Z","timestamp":1574727147000},"score":1,"resource":{"primary":{"URL":"https:\/\/aacnjournals.org\/ccnonline\/article\/38\/1\/30\/3579\/Transcatheter-Pulmonary-Valve-Replacement-in"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2018,2,1]]},"references-count":25,"journal-issue":{"issue":"1","published-print":{"date-parts":[[2018,2,1]]}},"URL":"https:\/\/doi.org\/10.4037\/ccn2018581","relation":{},"ISSN":["0279-5442","1940-8250"],"issn-type":[{"value":"0279-5442","type":"print"},{"value":"1940-8250","type":"electronic"}],"subject":[],"published":{"date-parts":[[2018,2,1]]}}}