{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,6]],"date-time":"2026-10-06T18:53:50Z","timestamp":1791312830214,"version":"4.3.1"},"reference-count":71,"publisher":"Korean Diabetes Association","issue":"1","license":[{"start":{"date-parts":[[2023,1,12]],"date-time":"2023-01-12T00:00:00Z","timestamp":1673481600000},"content-version":"tdm","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by-nc\/4.0\/"}],"content-domain":{"domain":["e-dmj.org"],"crossmark-restriction":true},"short-container-title":["Diabetes Metab J"],"published-print":{"date-parts":[[2023,1,31]]},"abstract":"<jats:p>Continuous glucose monitoring (CGM) technology has evolved over the past decade with the integration of various devices including insulin pumps, connected insulin pens (CIPs), automated insulin delivery (AID) systems, and virtual platforms. CGM has shown consistent benefits in glycemic outcomes in type 1 diabetes mellitus (T1DM) and type 2 diabetes mellitus (T2DM) treated with insulin. Moreover, the combined effect of CGM and education have been shown to improve glycemic outcomes more than CGM alone. Now a CIP is the expected future technology that does not need to be worn all day like insulin pumps and helps to calculate insulin doses with a built-in bolus calculator. Although only a few clinical trials have assessed the effectiveness of CIPs, they consistently show benefits in glycemic outcomes by reducing missed doses of insulin and improving problematic adherence. AID systems and virtual platforms made it possible to achieve target glycosylated hemoglobin in diabetes while minimizing hypoglycemia, which has always been challenging in T1DM. Now fully automatic AID systems and tools for diabetes decisions based on artificial intelligence are in development. These advances in technology could reduce the burden associated with insulin treatment for diabetes.<\/jats:p>","DOI":"10.4093\/dmj.2022.0271","type":"journal-article","created":{"date-parts":[[2023,1,27]],"date-time":"2023-01-27T00:48:16Z","timestamp":1674780496000},"page":"27-41","update-policy":"https:\/\/doi.org\/10.4093\/crossmark_policy","source":"Crossref","is-referenced-by-count":85,"title":["Advances in Continuous Glucose Monitoring and Integrated Devices for Management of Diabetes with Insulin-Based Therapy: Improvement in Glycemic Control"],"prefix":"10.4093","volume":"47","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-2536-6274","authenticated-orcid":true,"given":"Jee Hee","family":"Yoo","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-5001-963X","authenticated-orcid":true,"given":"Jae Hyeon","family":"Kim","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"2567","reference":[{"key":"ref1","doi-asserted-by":"publisher","DOI":"10.4093\/dmj.2020.0257"},{"key":"ref2","doi-asserted-by":"publisher","DOI":"10.1111\/dme.14528"},{"key":"ref3","doi-asserted-by":"publisher","DOI":"10.1177\/1932296818759845"},{"key":"ref4","doi-asserted-by":"publisher","DOI":"10.2337\/dci19-0062"},{"key":"ref5","doi-asserted-by":"publisher","DOI":"10.1016\/s0140-6736(19)31142-0"},{"key":"ref6","doi-asserted-by":"publisher","DOI":"10.1080\/09674845.2012.12002443"},{"key":"ref7","doi-asserted-by":"publisher","DOI":"10.1177\/1932296816667749"},{"key":"ref8","doi-asserted-by":"publisher","DOI":"10.2337\/dc16-2482"},{"key":"ref9","doi-asserted-by":"publisher","DOI":"10.2337\/dc22-s007"},{"key":"ref10","doi-asserted-by":"publisher","DOI":"10.1089\/dia.2018.0150"},{"key":"ref11","doi-asserted-by":"publisher","DOI":"10.1089\/dia.2014.0378"},{"key":"ref12","doi-asserted-by":"publisher","DOI":"10.1177\/1932296820958754"},{"key":"ref13","volume-title":"GUARDIAN(TM) SENSOR 3"},{"key":"ref14","volume-title":"InPen"},{"key":"ref15","volume-title":"MiniMed(TM) 780G system with Guardian(TM) 4 sensor"},{"key":"ref16","doi-asserted-by":"publisher","DOI":"10.1089\/dia.2017.0142"},{"key":"ref17","doi-asserted-by":"publisher","DOI":"10.1089\/dia.2022.0011"},{"key":"ref18","volume-title":"Dexcom CEO Sayer on G7 FDA submission, developing a 15-day sensor, M&amp;A plans","author":"Zipp"},{"key":"ref19","doi-asserted-by":"publisher","DOI":"10.1089\/dia.2021.0182"},{"key":"ref20","doi-asserted-by":"publisher","DOI":"10.3390\/s21206704"},{"key":"ref21","doi-asserted-by":"publisher","DOI":"10.1001\/jama.2016.19975"},{"key":"ref22","doi-asserted-by":"publisher","DOI":"10.1001\/jama.2016.19976"},{"key":"ref23","doi-asserted-by":"publisher","DOI":"10.7326\/m16-2855"},{"key":"ref24","first-page":"2262","volume-title":"Effect of continuous glucose monitoring on glycemic control in patients with type 2 diabetes treated with basal insulin: a randomized clinical trial","author":"Martens","year":"2021"},{"key":"ref25","doi-asserted-by":"publisher","DOI":"10.1016\/s0140-6736(18)30297-6"},{"key":"ref26","first-page":"2729","volume-title":"The effect of discontinuing continuous glucose monitoring in adults with type 2 diabetes treated with basal insulin","author":"Aleppo","year":"2021"},{"key":"ref27","doi-asserted-by":"publisher","DOI":"10.1007\/s13300-016-0223-6"},{"key":"ref28","doi-asserted-by":"publisher","DOI":"10.1016\/s0140-6736(16)31535-5"},{"key":"ref29","doi-asserted-by":"publisher","DOI":"10.1007\/s00125-017-4527-5"},{"key":"ref30","doi-asserted-by":"publisher","DOI":"10.1089\/dia.2018.0177"},{"key":"ref31","doi-asserted-by":"publisher","DOI":"10.2337\/dc19-1459"},{"key":"ref32","first-page":"S83","volume-title":"6","author":"American Diabetes As","year":"2022"},{"key":"ref33","doi-asserted-by":"publisher","DOI":"10.2337\/dc19-2606"},{"key":"ref34","first-page":"464","volume-title":"A randomized clinical trial assessing continuous glucose monitoring (CGM) use with standardized education with or without a family behavioral intervention compared with fingerstick blood glucose monitoring in very young children with type 1 diabetes","year":"2021"},{"key":"ref35","doi-asserted-by":"publisher","DOI":"10.1016\/j.diabres.2019.03.003"},{"key":"ref36","doi-asserted-by":"publisher","DOI":"10.1111\/pedi.13155"},{"key":"ref37","doi-asserted-by":"publisher","DOI":"10.2337\/dc18-0166"},{"key":"ref38","doi-asserted-by":"publisher","DOI":"10.1016\/j.diabres.2022.109209"},{"key":"ref39","doi-asserted-by":"publisher","DOI":"10.1111\/dme.12128"},{"key":"ref40","doi-asserted-by":"publisher","DOI":"10.2337\/dc18-1631"},{"key":"ref41","doi-asserted-by":"publisher","DOI":"10.1089\/dia.2021.0239"},{"key":"ref42","doi-asserted-by":"publisher","DOI":"10.1089\/dia.2019.0411"},{"key":"ref43","doi-asserted-by":"publisher","DOI":"10.1007\/s13300-021-01177-w"},{"key":"ref44","doi-asserted-by":"publisher","DOI":"10.2337\/ds18-0011"},{"key":"ref45","doi-asserted-by":"publisher","DOI":"10.1177\/1932296820965600"},{"key":"ref46","first-page":"219","volume-title":"Impact of inpen smart insulin pen use on real-world glycemic and insulin dosing outcomes in individuals with poorly controlled diabetes","author":"Vigersky","year":"2021"},{"key":"ref47","volume-title":""},{"key":"ref48","volume-title":"Sanofi and Abbott partner to integrate glucose sensing and insulin delivery technologies to help change the way diabetes is managed"},{"key":"ref49","doi-asserted-by":"publisher","DOI":"10.1016\/j.eprac.2021.04.008"},{"key":"ref50","doi-asserted-by":"publisher","DOI":"10.1056\/nejmoa1907863"},{"key":"ref51","doi-asserted-by":"publisher","DOI":"10.1056\/nejmoa2004736"},{"key":"ref52","doi-asserted-by":"publisher","DOI":"10.1056\/nejmoa2111673"},{"key":"ref53","doi-asserted-by":"publisher","DOI":"10.4093\/dmj.2021.0177"},{"key":"ref54","doi-asserted-by":"publisher","DOI":"10.2337\/dc20-2250"},{"key":"ref55","doi-asserted-by":"publisher","DOI":"10.1089\/dia.2021.0319"},{"key":"ref56","doi-asserted-by":"publisher","DOI":"10.1186\/s12902-022-00996-7"},{"key":"ref57","doi-asserted-by":"publisher","DOI":"10.1136\/bmjopen-2021-050635"},{"key":"ref58","doi-asserted-by":"publisher","DOI":"10.1089\/dia.2021.0097"},{"key":"ref59","doi-asserted-by":"publisher","DOI":"10.2337\/figshare.14423636.v2"},{"key":"ref60","doi-asserted-by":"publisher","DOI":"10.2337\/figshare.19763350"},{"key":"ref61","volume-title":"Results from insulin-only bionic pancreas trial to be reported"},{"key":"ref62","doi-asserted-by":"publisher","DOI":"10.1016\/s2213-8587(21)00267-9"},{"key":"ref63","doi-asserted-by":"publisher","DOI":"10.4093\/dmj.2021.0011"},{"key":"ref64","doi-asserted-by":"publisher","DOI":"10.1089\/dia.2020.0535"},{"key":"ref65","doi-asserted-by":"publisher","DOI":"10.1089\/dia.2018.0214"},{"key":"ref66","first-page":"286","volume-title":"The CREATE trial: randomized clinical trial comparing open-source automated insulin delivery with sensor augmented pump therapy in type 1 diabetes","author":"Burside","year":"2022"},{"key":"ref67","doi-asserted-by":"publisher","DOI":"10.1089\/dia.2020.0042"},{"key":"ref68","doi-asserted-by":"publisher","DOI":"10.1080\/03007995.2021.1976737"},{"key":"ref69","doi-asserted-by":"publisher","DOI":"10.1007\/s13300-020-00831-z"},{"key":"ref70","doi-asserted-by":"publisher","DOI":"10.1089\/dia.2020.0618"},{"key":"ref71","doi-asserted-by":"publisher","DOI":"10.1177\/1932296820965561"}],"container-title":["Diabetes &amp; Metabolism Journal"],"original-title":[],"language":"en","link":[{"URL":"http:\/\/www.e-dmj.org\/upload\/pdf\/dmj-2022-0271.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/www.e-dmj.org\/journal\/view.php?doi=10.4093\/dmj.2022.0271","content-type":"unspecified","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/www.e-dmj.org\/upload\/pdf\/dmj-2022-0271.pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,2,2]],"date-time":"2023-02-02T07:00:14Z","timestamp":1675321214000},"score":1,"resource":{"primary":{"URL":"http:\/\/www.e-dmj.org\/journal\/view.php?doi=10.4093\/dmj.2022.0271"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2023,1,31]]},"references-count":71,"journal-issue":{"issue":"1","published-print":{"date-parts":[[2023,1]]}},"URL":"https:\/\/doi.org\/10.4093\/dmj.2022.0271","relation":{},"ISSN":["2233-6079","2233-6087"],"issn-type":[{"value":"2233-6079","type":"print"},{"value":"2233-6087","type":"electronic"}],"subject":[],"published":{"date-parts":[[2023,1,31]]},"assertion":[{"value":"2022-08-05","order":0,"name":"received","label":"Received","group":{"name":"publication_history","label":"Publication History"}},{"value":"2022-09-28","order":1,"name":"accepted","label":"Accepted","group":{"name":"publication_history","label":"Publication History"}},{"value":"2023-01-12","order":2,"name":"published","label":"Published online","group":{"name":"publication_history","label":"Publication History"}},{"value":"2023-01-31","order":3,"name":"published","label":"Print publication","group":{"name":"publication_history","label":"Publication History"}}]}}