{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,8,18]],"date-time":"2026-08-18T16:48:24Z","timestamp":1787071704971,"version":"build-2736575974"},"reference-count":16,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"2","content-domain":{"domain":["lww.com","ovid.com"],"crossmark-restriction":true},"short-container-title":[],"published-print":{"date-parts":[[2013,3]]},"abstract":"<jats:sec>\n                    <jats:title>Context:<\/jats:title>\n                    <jats:p>Literature suggests glottic view is better with straight blades while tracheal intubation is easier with curved blades.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Aims:<\/jats:title>\n                    <jats:p>\n                      To compare glottic view and ease of intubation with Macintosh, Miller, McCoy blades and the Trueview\n                      <jats:sup>\u00ae<\/jats:sup>\n                      laryngoscope.\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Settings and Design:<\/jats:title>\n                    <jats:p>This prospective randomised study was undertaken in operation theatres of a 550 bedded tertiary referral cancer centre after approval from the Institutional Review Board.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Methods:<\/jats:title>\n                    <jats:p>\n                      We compared the Macintosh, Miller, McCoy blades and the Trueview\n                      <jats:sup>\u00ae<\/jats:sup>\n                      laryngoscope for glottic visualisation and ease of tracheal intubation; in 120 patients undergoing elective cancer surgery; randomly divided into four groups. After induction of anaesthesia laryngoscopy was performed and trachea intubated. We recorded: Visualisation of glottis (Cormack Lehane grade), ease of intubation, number of attempts; need to change the blade and need for external laryngeal manipulation.\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Statistical Analysis:<\/jats:title>\n                    <jats:p>\n                      Demographic data, Mallampati classification were compared using the Chi-square test. A\n                      <jats:italic toggle=\"yes\">P<\/jats:italic>\n                      &lt;0.05 was considered significant.\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results:<\/jats:title>\n                    <jats:p>\n                      Grade 1 view was obtained most often (87% patients) with Trueview\n                      <jats:sup>\u00ae<\/jats:sup>\n                      laryngoscope. Intubation was easier (Grade 1) with Trueview\n                      <jats:sup>\u00ae<\/jats:sup>\n                      and McCoy blades (93% each). Seven patients needed two attempts; one patient in Miller group needed three attempts. No patient in McCoy and Trueview\n                      <jats:sup>\u00ae<\/jats:sup>\n                      Groups required external laryngeal manipulation.\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusions:<\/jats:title>\n                    <jats:p>\n                      We found that in patients with normal airway glottis was best visualised with Miller blade and Trueview\n                      <jats:sup>\u00ae<\/jats:sup>\n                      laryngoscope however, the trachea was more easily intubated with McCoy and Macintosh blades and Trueview\n                      <jats:sup>\u00ae<\/jats:sup>\n                      laryngoscope.\n                    <\/jats:p>\n                  <\/jats:sec>","DOI":"10.4103\/0019-5049.111846","type":"journal-article","created":{"date-parts":[[2013,5,15]],"date-time":"2013-05-15T02:20:38Z","timestamp":1368584438000},"page":"170-174","update-policy":"https:\/\/doi.org\/10.1097\/lww.0000000000001000","source":"Crossref","is-referenced-by-count":17,"title":["Comparison of glottic visualisation and ease of intubation with different laryngoscope blades"],"prefix":"10.4103","volume":"57","author":[{"given":"Atul P","family":"Kulkarni","sequence":"first","affiliation":[{"name":"Department of Anaesthesiology, Critical Care and Pain, Tata Memorial Hospital, Mumbai, Maharashtra, India"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Amar S","family":"Tirmanwar","sequence":"additional","affiliation":[{"name":"Department of Anaesthesiology, Critical Care and Pain, Tata Memorial Hospital, Mumbai, Maharashtra, India"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"276","reference":[{"key":"R1-20251205","doi-asserted-by":"crossref","first-page":"932","DOI":"10.1097\/00000542-199112000-00002","article-title":"Adverse respiratory events infrequently leading to malpractice suits. A closed claims analysis","volume":"75","author":"Cheney","year":"1991","journal-title":"Anesthesiology"},{"key":"R2-20251205","doi-asserted-by":"crossref","first-page":"1105","DOI":"10.1111\/j.1365-2044.1984.tb08932.x","article-title":"Difficult tracheal intubation in obstetrics","volume":"39","author":"Cormack","year":"1984","journal-title":"Anaesthesia"},{"key":"R3-20251205","doi-asserted-by":"crossref","first-page":"548","DOI":"10.1016\/j.annemergmed.2006.01.013","article-title":"Laryngeal view during laryngoscopy: A randomized trial comparing cricoid pressure, backward-upward-rightward pressure, and bimanual laryngoscopy","volume":"47","author":"Levitan","year":"2006","journal-title":"Ann Emerg Med"},{"key":"R4-20251205","doi-asserted-by":"crossref","first-page":"501","DOI":"10.1007\/BF03021064","article-title":"Straight blades improve visualization of the larynx while curved blades increase ease of intubation: A comparison of the Macintosh, Miller, McCoy, Belscope and Lee-Fiberview blades","volume":"50","author":"Arino","year":"2003","journal-title":"Can J Anaesth"},{"key":"R5-20251205","doi-asserted-by":"crossref","first-page":"487","DOI":"10.1111\/j.1365-2044.1987.tb04039.x","article-title":"Difficult tracheal intubation: A retrospective study","volume":"42","author":"Samsoon","year":"1987","journal-title":"Anaesthesia"},{"key":"R6-20251205","doi-asserted-by":"crossref","first-page":"136","DOI":"10.1016\/0952-8180(95)00198-0","article-title":"Quantitative improvement in laryngoscopic view by optimal external laryngeal manipulation","volume":"8","author":"Benumof","year":"1996","journal-title":"J Clin Anesth"},{"key":"R7-20251205","doi-asserted-by":"crossref","first-page":"1249","DOI":"10.1111\/j.1365-2044.1984.tb06446.x","article-title":"Improved vision modification of the Macintosh laryngoscope","volume":"39","author":"Racz","year":"1984","journal-title":"Anaesthesia"},{"key":"R8-20251205","doi-asserted-by":"crossref","first-page":"884","DOI":"10.1097\/01.anes.0000291461.62404.46","article-title":"Craniocervical motion during direct laryngoscopy and orotracheal intubation with the Macintosh and Miller blades: An in vivo cinefluoroscopic study","volume":"107","author":"LeGrand","year":"2007","journal-title":"Anesthesiology"},{"key":"R9-20251205","doi-asserted-by":"crossref","first-page":"1335","DOI":"10.1097\/00000542-199712000-00012","article-title":"Comparison of the Bullard and Macintosh laryngoscopes for endotracheal intubation of patients with a potential cervical spine injury","volume":"87","author":"Watts","year":"1997","journal-title":"Anesthesiology"},{"key":"R10-20251205","doi-asserted-by":"crossref","first-page":"717","DOI":"10.1177\/0310057X0803600515","article-title":"View of the larynx obtained using the Miller blade and paraglossal approach, compared to that with the Macintosh blade","volume":"36","author":"Achen","year":"2008","journal-title":"Anaesth Intensive Care"},{"key":"R11-20251205","doi-asserted-by":"crossref","first-page":"674","DOI":"10.1007\/BF03015455","article-title":"The McCoy levering laryngoscope in patients with limited neck extension","volume":"44","author":"Uchida","year":"1997","journal-title":"Can J Anaesth"},{"key":"R12-20251205","first-page":"1257","article-title":"Determination of the distance between the upper incisors and the laryngoscope blade during laryngoscopy: Comparisons of the McCoy, the Macintosh, the Miller, and the Belscope blades","volume":"47","author":"Bito","year":"1998","journal-title":"Masui"},{"key":"R13-20251205","doi-asserted-by":"crossref","first-page":"626","DOI":"10.1213\/01.ane.0000185035.89265.3c","article-title":"A clinical comparison of the Flexiblade and Macintosh laryngoscopes for laryngeal exposure in anesthetized adults","volume":"102","author":"Cheung","year":"2006","journal-title":"Anesth Analg"},{"key":"R14-20251205","doi-asserted-by":"crossref","first-page":"827","DOI":"10.1111\/j.1365-2044.2007.05143.x","article-title":"A comparison of the Truview blade with the Macintosh blade in adult patients","volume":"62","author":"Barak","year":"2007","journal-title":"Anaesthesia"},{"key":"R15-20251205","doi-asserted-by":"crossref","first-page":"940","DOI":"10.1111\/j.1365-2044.2007.05182.x","article-title":"An evaluation of the TruView EVO2 laryngoscope","volume":"62","author":"Li","year":"2007","journal-title":"Anaesthesia"},{"key":"R16-20251205","doi-asserted-by":"crossref","first-page":"446","DOI":"10.1017\/S0265021508003657","article-title":"Evaluation of new laryngoscope blade for tracheal intubation, Truview EVO2: A manikin study","volume":"25","author":"Miceli","year":"2008","journal-title":"Eur J Anaesthesiol"}],"container-title":["Indian Journal of Anaesthesia"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.ovid.com\/01762628-201357020-00011","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,8,18]],"date-time":"2026-08-18T15:51:42Z","timestamp":1787068302000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.ovid.com\/01762628-201357020-00011"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2013,3]]},"references-count":16,"journal-issue":{"issue":"2","published-print":{"date-parts":[[2013]]}},"URL":"https:\/\/doi.org\/10.4103\/0019-5049.111846","relation":{},"ISSN":["0019-5049","0976-2817"],"issn-type":[{"value":"0019-5049","type":"print"},{"value":"0976-2817","type":"electronic"}],"subject":[],"published":{"date-parts":[[2013,3]]}}}