{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,8,18]],"date-time":"2026-08-18T16:48:00Z","timestamp":1787071680352,"version":"build-2736575974"},"reference-count":30,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"1","content-domain":{"domain":["lww.com","ovid.com"],"crossmark-restriction":true},"short-container-title":[],"published-print":{"date-parts":[[2011,1]]},"abstract":"<jats:p>A Robotic device is a powered, computer controlled manipulator with artificial sensing that can be reprogrammed to move and position tools to carry out a wide range of tasks. Robots and Telemanipulators were first developed by the National Aeronautics and Space Administration (NASA) for use in space exploration. Today\u2019s medical robotic systems were the brainchild of the United States Department of Defence\u2019s desire to decrease war casualties with the development of \u2018telerobotic surgery\u2019. The \u2018master-slave\u2019 telemanipulator concept was developed for medical use in the early 1990s where the surgeon\u2019s (master) manual movements were transmitted to end-effector (slave) instruments at a remote site. Since then, the field of surgical robotics has undergone massive transformation and the future is even brighter. As expected, any new technique brings with it risks and the possibility of technical difficulties. The person who bears the brunt of complications or benefit from a new invention is the \u2018Patient\u2019. Anaesthesiologists as always must do their part to be the patient\u2019s \u2018best man\u2019 in the perioperative period. We should be prepared for screening and selection of patients in a different perspective keeping in mind the steep learning curves of surgeons, long surgical hours, extreme patient positioning and other previously unknown anaesthetic challenges brought about by the surgical robot. In this article we have tried to track the development of surgical robots and consider the unique anaesthetic issues related to robot assisted surgeries.<\/jats:p>","DOI":"10.4103\/0019-5049.76577","type":"journal-article","created":{"date-parts":[[2011,4,8]],"date-time":"2011-04-08T17:54:12Z","timestamp":1302285252000},"page":"18-25","update-policy":"https:\/\/doi.org\/10.1097\/lww.0000000000001000","source":"Crossref","is-referenced-by-count":26,"title":["Robotic invasion of operation theatre and associated anaesthetic issues: A review"],"prefix":"10.4103","volume":"55","author":[{"given":"Prem N","family":"Kakar","sequence":"first","affiliation":[{"name":"Department of Anesthesiology Pain Management and Perioperative Care, Fortis Hospital, Shalimar Bagh, New Delhi, India"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jyotirmoy","family":"Das","sequence":"additional","affiliation":[{"name":"Department of Anesthesiology Pain Management and Perioperative Care, Fortis Hospital, Shalimar Bagh, New Delhi, India"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Preeti Mittal","family":"Roy","sequence":"additional","affiliation":[{"name":"Department of Anesthesiology Pain Management and Perioperative Care, Fortis Hospital, Shalimar Bagh, New Delhi, India"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Vijaya","family":"Pant","sequence":"additional","affiliation":[{"name":"Department of Anesthesiology Pain Management and Perioperative Care, Fortis Hospital, Shalimar Bagh, New Delhi, India"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"276","reference":[{"key":"R1-20251205","doi-asserted-by":"crossref","first-page":"6","DOI":"10.1097\/00129689-200202000-00002","article-title":"Surgical robotics: The early chronicles: A personal historical perspective","volume":"12","author":"Satava","year":"2002","journal-title":"Surg Laparosc Endosc Percutan Tech"},{"key":"R2-20251205","doi-asserted-by":"crossref","first-page":"113","DOI":"10.1007\/BF00058758","article-title":"NASA\u2019s Telerobotic research program","volume":"2","author":"Weisbin","year":"1992","journal-title":"Appl Intell"},{"key":"R4-20251205","volume":"1","author":"Vertut","year":"1986","journal-title":"Teleoperation and Robotics: Evolution and Development"},{"key":"R5-20251205","doi-asserted-by":"crossref","first-page":"625","DOI":"10.1163\/156855395X00337","article-title":"Robots in space: A survey","volume":"9","author":"Hirzinger","year":"1994","journal-title":"Adv Robot"},{"key":"R6-20251205","first-page":"1550","article-title":"Precise EV robot: Flight model and telerobotic operation for ETS-VII","volume":"3","author":"Machida","year":"1996","journal-title":"IEEE Explore Digital Libr"},{"key":"R8-20251205","first-page":"2000","article-title":"A telerobot control system for accident response","volume":"2","author":"Anderson","year":"2000","journal-title":"IEEE Explore Digital Libr"},{"key":"R9-20251205","doi-asserted-by":"crossref","first-page":"487","DOI":"10.1016\/0005-1098(89)90093-9","article-title":"Telerobotics","volume":"25","author":"Sheridan","year":"1989","journal-title":"Automatica"},{"key":"R11-20251205","first-page":"215","article-title":"Robotics in surgery","volume":"10","author":"Darzi","year":"2002","journal-title":"Stud BMJ"},{"key":"R13-20251205","doi-asserted-by":"crossref","first-page":"1091","DOI":"10.1007\/s004649900788","article-title":"Telesurgical laparoscopic cholecystectomy","volume":"12","author":"Himpens","year":"1998","journal-title":"Surg Endosc"},{"key":"R14-20251205","doi-asserted-by":"crossref","first-page":"487","DOI":"10.1097\/00000658-200204000-00005","article-title":"Transcontinental robot-assisted remote telesurgery: Feasibility and potential application","volume":"235","author":"Marescaux","year":"2002","journal-title":"Ann Surg"},{"key":"R15-20251205","doi-asserted-by":"crossref","first-page":"379","DOI":"10.1038\/35096636","article-title":"Transatlantic robot-assisted telesurgery","volume":"413","author":"Marescaux","year":"2001","journal-title":"Nature"},{"key":"R16-20251205","doi-asserted-by":"crossref","first-page":"14","DOI":"10.1097\/01.sla.0000103020.19595.7d","article-title":"Robotic surgery: A current perspective","volume":"239","author":"Lanfranco","year":"2004","journal-title":"Ann Surg"},{"key":"R17-20251205","doi-asserted-by":"crossref","first-page":"e862","DOI":"10.1371\/journal.pone.0000862","article-title":"A fully automated robotic system for microinjection of zebrafish embryos","volume":"2","author":"Wang","year":"2007","journal-title":"PLoS One"},{"key":"R18-20251205","first-page":"489","article-title":"Robotic surgery: State of the art and future trends","volume":"57","author":"Satava","year":"2001","journal-title":"Contemp Surg"},{"key":"R19-20251205","doi-asserted-by":"crossref","first-page":"191","DOI":"10.1089\/1092642041255441","article-title":"Application of haptic feedback to robotic surgery","volume":"14","author":"Bethea","year":"2004","journal-title":"J Laparoendosc Adv Surg Tech A"},{"key":"R20-20251205","first-page":"242","article-title":"Robot-assisted surgery: The future is here","volume":"48","author":"Gerhardus","year":"2003","journal-title":"J Healthc Manag"},{"key":"R21-20251205","doi-asserted-by":"crossref","first-page":"101","DOI":"10.1007\/s002219900286","article-title":"Adaptation to visual feedback delays in a human manual tracking tasks","volume":"131","author":"Foulkes","year":"2000","journal-title":"Exp Brain Res"},{"key":"R24-20251205","doi-asserted-by":"crossref","first-page":"235","DOI":"10.3109\/13645709909153167","article-title":"Dexterity enhancement in endoscopic surgery by a computer controlled mechanical wrist","volume":"8","author":"Falk","year":"1999","journal-title":"Min Inv Therapy Allied Tech"},{"key":"R27-20251205","doi-asserted-by":"crossref","first-page":"146","DOI":"10.1097\/00001573-200103000-00012","article-title":"Robotic cardiac valve surgery: Transcending the technologic crevasse!","volume":"16","author":"Felger","year":"2001","journal-title":"Curr Opin Cardiol"},{"key":"R28-20251205","doi-asserted-by":"crossref","first-page":"859","DOI":"10.1093\/bja\/aeh274","article-title":"Anaesthesia for laparoscopic urological surgery","volume":"93","author":"Conacher","year":"2004","journal-title":"Br J Anaesth"},{"key":"R29-20251205","doi-asserted-by":"crossref","first-page":"454S","DOI":"10.1378\/chest.08-0658","article-title":"Antithrombotic Therapy for venous thromboembolic disease. American College of Chest Physicians Evidence- Based Clinical Practice Guidelines","volume":"133","author":"Kearo","year":"2008","journal-title":"Chest"},{"key":"R30-20251205","doi-asserted-by":"crossref","first-page":"225","DOI":"10.1089\/109264202760267970","article-title":"Robotic gastrointestinal surgery: Early experience and system description","volume":"12","author":"Talamini","year":"2002","journal-title":"J Laparoendosc Adv Surg Tech A"},{"key":"R31-20251205","doi-asserted-by":"crossref","first-page":"312","DOI":"10.1002\/rcs.165","article-title":"Cardiac function during steep Trendelenburg position and CO2 pneumoperitoneum for robotic-assisted prostatectomy: A trans-oesophageal Doppler probe study","volume":"3","author":"Falabella","year":"2007","journal-title":"Int J Med Robot"},{"key":"R32-20251205","doi-asserted-by":"crossref","first-page":"895","DOI":"10.1111\/j.1399-6576.2009.01991.x","article-title":"The effect of pneumoperitoneum in the steep Trendelenburg position on cerebral oxygenation","volume":"53","author":"Park","year":"2009","journal-title":"Acta Anaesthesiol Scand"},{"key":"R33-20251205","doi-asserted-by":"crossref","first-page":"433","DOI":"10.1093\/bja\/aeq018","article-title":"Influence of steep Trendelenburg position and CO2 pneumoperitoneum on cardiovascular, cerebrovascular, and respiratory homeostasis during robotic prostatectomy","volume":"104","author":"Kalmar","year":"2010","journal-title":"Br J Anaesth"},{"key":"R34-20251205","doi-asserted-by":"crossref","first-page":"473","DOI":"10.1213\/ane.0b013e3181a9098f","article-title":"The effects of steep Trendelenburg positioning on intraocular pressure during robotic radical prostatectomy","volume":"109","author":"Awad","year":"2009","journal-title":"Anaesth Analg"},{"key":"R35-20251205","doi-asserted-by":"crossref","first-page":"281","DOI":"10.1177\/0310057X0703500221","article-title":"Anaesthesia for robotic-assisted radical prostatectomy: Considerations for laparoscopy in the Trendelenburg position","volume":"35","author":"Phong","year":"2007","journal-title":"Anaesth Intensive Care"},{"key":"R36-20251205","doi-asserted-by":"crossref","first-page":"678","DOI":"10.1007\/BF03015458","article-title":"Bilateral compartment syndrome following prolonged anaesthesia in the lithotomy position","volume":"44","author":"Fabbri","year":"1997","journal-title":"Can J Anaesth"},{"key":"R37-20251205","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1213\/00000539-200301000-00001","article-title":"Challenges for the anaesthesiologist: Robotics?","volume":"96","author":"Nifong","year":"2003","journal-title":"Anaesth Analg"},{"key":"R38-20251205","doi-asserted-by":"crossref","first-page":"1665","DOI":"10.1213\/01.ANE.0000137394.99683.66","article-title":"Anaesthetic concerns for robot-assisted laparoscopy in an infant","volume":"99","author":"Mariano","year":"2004","journal-title":"Anaesth Analg"}],"container-title":["Indian Journal of Anaesthesia"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.ovid.com\/01762628-201155010-00006","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,8,18]],"date-time":"2026-08-18T15:50:59Z","timestamp":1787068259000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.ovid.com\/01762628-201155010-00006"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2011,1]]},"references-count":30,"journal-issue":{"issue":"1","published-print":{"date-parts":[[2011]]}},"URL":"https:\/\/doi.org\/10.4103\/0019-5049.76577","relation":{},"ISSN":["0019-5049","0976-2817"],"issn-type":[{"value":"0019-5049","type":"print"},{"value":"0976-2817","type":"electronic"}],"subject":[],"published":{"date-parts":[[2011,1]]}}}