{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2022,4,1]],"date-time":"2022-04-01T19:44:49Z","timestamp":1648842289663},"reference-count":28,"publisher":"Springer Science and Business Media LLC","issue":"6","license":[{"start":{"date-parts":[[2016,12,1]],"date-time":"2016-12-01T00:00:00Z","timestamp":1480550400000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.springer.com\/tdm"},{"start":{"date-parts":[[2016,12,1]],"date-time":"2016-12-01T00:00:00Z","timestamp":1480550400000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/www.springer.com\/tdm"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["IJOO"],"published-print":{"date-parts":[[2016,12]]},"DOI":"10.4103\/0019-5413.193488","type":"journal-article","created":{"date-parts":[[2016,11,7]],"date-time":"2016-11-07T07:27:39Z","timestamp":1478503659000},"page":"647-654","update-policy":"http:\/\/dx.doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":0,"title":["What have we learned from 100% success of press fit condylar rotating platform posterior stabilized knees?"],"prefix":"10.1007","volume":"50","author":[{"given":"Shrinand V.","family":"Vaidya","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Siddharth","family":"Virani","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Rajendra","family":"Phunde","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Abhishek","family":"Mahajan","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"297","published-online":{"date-parts":[[2016,12,1]]},"reference":[{"key":"5006647_CR1","doi-asserted-by":"publisher","first-page":"108","DOI":"10.1080\/17453670610013501","volume":"78","author":"P R\u00e4s\u00e4nen","year":"2007","unstructured":"R\u00e4s\u00e4nen P, Paavolainen P, Sintonen H, Koivisto AM, Blom M, Ryyn\u00e4nen OP, et al. Effectiveness of hip or knee replacement surgery in terms of quality-adjusted life years and costs. Acta Orthop 2007;78:108\u201315.","journal-title":"Acta Orthop"},{"key":"5006647_CR2","doi-asserted-by":"publisher","first-page":"1619","DOI":"10.2106\/00004623-199311000-00006","volume":"75","author":"A Laupacis","year":"1993","unstructured":"Laupacis A, Bourne R, Rorabeck C, Feeny D, Wong C, Tugwell P, et al. The effect of elective total hip replacement on healthrelated quality of life. J Bone Joint Surg Am 1993;75:1619\u201326.","journal-title":"J Bone Joint Surg Am"},{"key":"5006647_CR3","doi-asserted-by":"publisher","first-page":"963","DOI":"10.2106\/00004623-200405000-00012","volume":"86-A","author":"O Ethgen","year":"2004","unstructured":"Ethgen O, Bruy\u00e8re O, Richy F, Dardennes C, Reginster JY. Healthrelated quality of life in total hip and total knee arthroplasty. A qualitative and systematic review of the literature. J Bone Joint Surg Am 2004;86-A: 963\u201374.","journal-title":"J Bone Joint Surg Am"},{"key":"5006647_CR4","doi-asserted-by":"publisher","first-page":"1088","DOI":"10.1016\/0140-6736(92)90673-Q","volume":"339","author":"CA O\u2019Boyle","year":"1992","unstructured":"O\u2019Boyle CA, McGee H, Hickey A, O\u2019Malley K, Joyce CR. Individual quality of life in patients undergoing hip replacement. Lancet 1992;339:1088\u201391.","journal-title":"Lancet"},{"key":"5006647_CR5","doi-asserted-by":"publisher","first-page":"638","DOI":"10.2106\/JBJS.K.00263","volume":"94","author":"JN Argenson","year":"2012","unstructured":"Argenson JN, Parratte S, Ashour A, Saintmard B, Aubaniac JM. The outcome of rotating-platform total knee arthroplasty with cement at a minimum of ten years of followup. J Bone Joint Surg Am 2012;94:638\u201344.","journal-title":"J Bone Joint Surg Am"},{"key":"5006647_CR6","doi-asserted-by":"publisher","first-page":"40","DOI":"10.1097\/00003086-200211000-00008","volume":"404","author":"F Sr Buechel","year":"2002","unstructured":"Buechel FF Sr. Long term followup after mobile-bearing total knee replacement. Clin Orthop Relat Res 2002;404 40\u201350.","journal-title":"Clin Orthop Relat Res"},{"key":"5006647_CR7","first-page":"84","volume":"15","author":"FF Buechel Sr.","year":"2002","unstructured":"Buechel FF Sr., Buechel FF Jr., Pappas MJ, Dalessio J. Twentyyear evaluation of the New Jersey LCS Rotating Platform Knee Replacement. J Knee Surg 2002;15:84\u20139.","journal-title":"J Knee Surg"},{"key":"5006647_CR8","doi-asserted-by":"publisher","first-page":"426","DOI":"10.2106\/JBJS.K.00152","volume":"94","author":"M Meftah","year":"2012","unstructured":"Meftah M, Ranawat AS, Ranawat CS. Ten-year followup of a rotating-platform, posterior-stabilized total knee arthroplasty. J Bone Joint Surg Am 2012;94:426\u201332.","journal-title":"J Bone Joint Surg Am"},{"key":"5006647_CR9","doi-asserted-by":"publisher","first-page":"543","DOI":"10.1016\/j.arth.2010.04.025","volume":"26","author":"RN Maniar","year":"2011","unstructured":"Maniar RN, Gupta H, Singh A, Johorey AC, Singhi T. Five- to eight-year results of a prospective study in 118 arthroplasties using posterior-stabilized rotating-platform knee implants. J Arthroplasty 2011;26:543\u20138.","journal-title":"J Arthroplasty"},{"key":"5006647_CR10","doi-asserted-by":"publisher","first-page":"40","DOI":"10.4103\/0019-5413.106898","volume":"47","author":"SV Vaidya","year":"2013","unstructured":"Vaidya SV, Gadhiya RM, Bagaria V, Ranawat AS, Ranawat CS. Computed tomographic evaluation of femoral component rotation in total knee arthroplasty. Indian J Orthop 2013;47:40\u20134.","journal-title":"Indian J Orthop"},{"key":"5006647_CR11","doi-asserted-by":"crossref","unstructured":"Hopley CD, Crossett LS, Chen AF. Long term clinical outcomes and survivorship after total knee arthroplasty using a rotating platform knee prosthesis: A meta-analysis. J Arthroplasty 2013;28:68-77.e1-3.","DOI":"10.1016\/j.arth.2012.04.026"},{"key":"5006647_CR12","doi-asserted-by":"publisher","first-page":"537","DOI":"10.1016\/j.arth.2010.05.015","volume":"26","author":"JT Carothers","year":"2011","unstructured":"Carothers JT, Kim RH, Dennis DA, Southworth C. Mobilebearing total knee arthroplasty: A meta-analysis. J Arthroplasty 2011;26:537\u201342.","journal-title":"J Arthroplasty"},{"key":"5006647_CR13","doi-asserted-by":"publisher","first-page":"69","DOI":"10.1097\/01.blo.0000062384.79828.3b","volume":"410","author":"RD Komistek","year":"2003","unstructured":"Komistek RD, Dennis DA, Mahfouz M. In vivo fluoroscopic analysis of the normal human knee. Clin Orthop Relat Res 2003;410:69\u201381.","journal-title":"Clin Orthop Relat Res"},{"key":"5006647_CR14","doi-asserted-by":"publisher","first-page":"33","DOI":"10.1302\/0301-620X.83B1.0830033","volume":"83","author":"DA Dennis","year":"2001","unstructured":"Dennis DA, Komistek RD, Walker SA, Cheal EJ, Stiehl JB. Femoral condylar lift-off in vivo in total knee arthroplasty. J Bone Joint Surg Br 2001;83:33\u20139.","journal-title":"J Bone Joint Surg Br"},{"key":"5006647_CR15","doi-asserted-by":"publisher","first-page":"390","DOI":"10.2106\/00004623-200103000-00011","volume":"83-A","author":"SK Puloski","year":"2001","unstructured":"Puloski SK, McCalden RW, MacDonald SJ, Rorabeck CH, Bourne RB. Tibial post wear in posterior stabilized total knee arthroplasty. An unrecognized source of polyethylene debris. J Bone Joint Surg Am 2001;83-A:390\u20137.","journal-title":"J Bone Joint Surg Am"},{"key":"5006647_CR16","first-page":"274","volume":"57","author":"GK Dendrinos","year":"1991","unstructured":"Dendrinos GK, Mavropoulou A, Polyzoides AJ. Late failure and revisions of old-type total knee replacements. Acta Orthop Belg 1991;57:274\u201384.","journal-title":"Acta Orthop Belg"},{"key":"5006647_CR17","doi-asserted-by":"publisher","first-page":"1660","DOI":"10.2106\/00004623-200111000-00007","volume":"83-A","author":"GA Engh","year":"2001","unstructured":"Engh GA, Lounici S, Rao AR, Collier MB. In vivo deterioration of tibial baseplate locking mechanisms in contemporary modular total knee components. J Bone Joint Surg Am 2001;83-A:1660\u20135.","journal-title":"J Bone Joint Surg Am"},{"key":"5006647_CR18","doi-asserted-by":"publisher","first-page":"1849","DOI":"10.2106\/00004623-200210000-00017","volume":"84-A","author":"AR Rao","year":"2002","unstructured":"Rao AR, Engh GA, Collier MB, Lounici S. Tibial interface wear in retrieved total knee components and correlations with modular insert motion. J Bone Joint Surg Am 2002;84-A:1849\u201355.","journal-title":"J Bone Joint Surg Am"},{"key":"5006647_CR19","doi-asserted-by":"publisher","first-page":"53","DOI":"10.1097\/00003086-199712000-00009","volume":"345","author":"RC Wasielewski","year":"1997","unstructured":"Wasielewski RC, Parks N, Williams I, Surprenant H, Collier JP, Engh G. Tibial insert undersurface as a contributing source of polyethylene wear debris. Clin Orthop Relat Res 1997;345:53\u20139.","journal-title":"Clin Orthop Relat Res"},{"key":"5006647_CR20","doi-asserted-by":"publisher","first-page":"705","DOI":"10.2106\/00004623-200005000-00011","volume":"82","author":"JJ Callaghan","year":"2000","unstructured":"Callaghan JJ, Squire MW, Goetz DD, Sullivan PM, Johnston RC. Cemented rotating-platform total knee replacement. A nine to twelve-year followup study. J Bone Joint Surg Am 2000;82:705\u201311.","journal-title":"J Bone Joint Surg Am"},{"key":"5006647_CR21","doi-asserted-by":"crossref","first-page":"253","DOI":"10.1097\/00003086-199112000-00036","volume":"273","author":"GW Blunn","year":"1991","unstructured":"Blunn GW, Walker PS, Joshi A, Hardinge K. The dominance of cyclic sliding in producing wear in total knee replacements. Clin Orthop Relat Res 1991;273:253\u201360.","journal-title":"Clin Orthop Relat Res"},{"key":"5006647_CR22","doi-asserted-by":"publisher","first-page":"232","DOI":"10.1097\/00003086-200111000-00029","volume":"392","author":"DD D\u2019Lima","year":"2001","unstructured":"D\u2019Lima DD, Chen PC, Colwell CW Jr. Polyethylene contact stresses, articular congruity, and knee alignment. Clin Orthop Relat Res 2001;392:232\u20138.","journal-title":"Clin Orthop Relat Res"},{"key":"5006647_CR23","volume-title":"70 th Annual Meeting of the American Academe of Orthopedic Surgeons","author":"S Greenwald","year":"2003","unstructured":"Greenwald S. Mobile Bearing Knees: What\u2019s the Fuss all about? 70 th Annual Meeting of the American Academe of Orthopedic Surgeons. New Orleans, Louisiana: Instructional Course Lectures; 5-9 February, 2003."},{"key":"5006647_CR24","first-page":"638","volume":"73","author":"C Stukenborg-Colsman","year":"2002","unstructured":"Stukenborg-Colsman C, Ostermeier S, Hurschler C, Wirth CJ. Tibiofemoral contact stress after total knee arthroplasty: Comparison of fixed and mobile-bearing inlay designs. Acta Orthop Scand 2002;73:638\u201346.","journal-title":"Acta Orthop Scand"},{"key":"5006647_CR25","first-page":"189","volume":"9","author":"VC Jones","year":"1999","unstructured":"Jones VC, Barton DC, Fitzpatrick DP, Auger DD, Stone MH, Fisher J. An experimental model of tibial counterface polyethylene wear in mobile bearing knees: The influence of design and kinematics. Biomed Mater Eng 1999;9:189\u201396.","journal-title":"Biomed Mater Eng"},{"key":"5006647_CR26","doi-asserted-by":"publisher","first-page":"189","DOI":"10.1097\/00003086-200212000-00024","volume":"405","author":"CH Huang","year":"2002","unstructured":"Huang CH, Ma HM, Liau JJ, Ho FY, Cheng CK. Late dislocation of rotating platform in New Jersey low-contact stress knee prosthesis. Clin Orthop Relat Res 2002;405:189\u201394.","journal-title":"Clin Orthop Relat Res"},{"key":"5006647_CR27","doi-asserted-by":"publisher","first-page":"728","DOI":"10.1016\/j.arth.2012.08.027","volume":"28","author":"H Bedair","year":"2013","unstructured":"Bedair H, Lawless B, Malchau H. Are implant designer series believable? Comparison of survivorship between designer series and national registries. J Arthroplasty 2013;28:728\u201331.","journal-title":"J Arthroplasty"},{"key":"5006647_CR28","doi-asserted-by":"publisher","first-page":"132","DOI":"10.1016\/j.arth.2015.07.032","volume":"31","author":"JH Lee","year":"2016","unstructured":"Lee JH, Barnett SL, Patel JJ, Nassif NA, Cummings DJ, Gorab RS. Ten Year FollowUp of Gap Balanced, Rotating Platform Total Knee Arthroplasty in Patients Under 60 Years of Age. J Arthroplasty 2016;31:132\u20136.","journal-title":"J Arthroplasty"}],"container-title":["Indian Journal of Orthopaedics"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.4103\/0019-5413.193488.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.4103\/0019-5413.193488\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.4103\/0019-5413.193488.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2022,2,10]],"date-time":"2022-02-10T19:52:48Z","timestamp":1644522768000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/10.4103\/0019-5413.193488"}},"subtitle":["A 5-10 years followup by a nondesigner"],"short-title":[],"issued":{"date-parts":[[2016,12]]},"references-count":28,"journal-issue":{"issue":"6","published-print":{"date-parts":[[2016,12]]}},"alternative-id":["5006647"],"URL":"https:\/\/doi.org\/10.4103\/0019-5413.193488","relation":{},"ISSN":["0019-5413","1998-3727"],"issn-type":[{"value":"0019-5413","type":"print"},{"value":"1998-3727","type":"electronic"}],"subject":[],"published":{"date-parts":[[2016,12]]},"assertion":[{"value":"1 December 2016","order":1,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}}]}}