{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,8,13]],"date-time":"2026-08-13T19:54:16Z","timestamp":1786650856892,"version":"build-2736575974"},"reference-count":11,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"6","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Neurol India"],"published-print":{"date-parts":[[2013]]},"DOI":"10.4103\/0028-3886.125274","type":"journal-article","created":{"date-parts":[[2014,1,18]],"date-time":"2014-01-18T01:58:16Z","timestamp":1390010296000},"page":"650","source":"Crossref","is-referenced-by-count":0,"title":["Indocyanine green video angiography-assisted surgical management of coil migration resulting from the endovascular treatment of anterior communicating artery aneurysm: Technical case report and instrumentation assessment"],"prefix":"10.4103","volume":"61","author":[{"given":"Zion","family":"Zibly","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"GustavoG","family":"Rajz","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Mayur","family":"Sharma","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Sagi","family":"Harnof","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"276","reference":[{"key":"key-10.4103\/0028-3886.125274-1","first-page":"135","volume-title":"Intraoperative Hypothermia for Aneurysm Surgery Trial (IHAST) Investigators.Mild intraoperative hypothermia during surgery for intracranial aneurysm","author":"Todd","year":"2005","journal-title":"N Engl J Med"},{"key":"key-10.4103\/0028-3886.125274-2","first-page":"132","volume-title":"Near-infrared indocyanine green video angiography: A new method for intraoperative assessment of vascular flow.Neurosurgery","author":"Raabe","year":"2003","journal-title":""},{"key":"key-10.4103\/0028-3886.125274-3","first-page":"1267","volume-title":"International Subarachnoid Aneurysm Trial (ISAT) Collaborative Group.International Subarachnoid Aneurysm Trial (ISAT) of neurosurgical clipping versus endovascular coiling in 2143 patients with ruptured intracranial aneurysms: A randomised trial","author":"Molyneux","year":"2002","journal-title":"Lancet"},{"key":"key-10.4103\/0028-3886.125274-4","first-page":"1743","volume-title":"Improved cognitive outcomes with endovascular coiling of ruptured intracranial aneurysms: Neuropsychological outcomes from the International Subarachnoid Aneurysm Trial (ISAT)","author":"Scott","year":"2010","journal-title":"Stroke"},{"key":"key-10.4103\/0028-3886.125274-5","first-page":"1609","volume-title":"Rescue microsurgery in coil herniation causing thromboembolic occlusion of parent artery","author":"Kim","year":"2009","journal-title":"Acta Neurochir (Wien)"},{"key":"key-10.4103\/0028-3886.125274-6","first-page":"ONS","volume-title":"Surgical management of distal coil migration and arterial perforation after attempted coil embolization of a ruptured ophthalmic artery aneurysm: Technical case report","author":"Deshmukh","year":"2006","journal-title":"Neurosurgery"},{"key":"key-10.4103\/0028-3886.125274-7","first-page":"10","volume-title":"Intraoperative angiography in cerebral aneurysm surgery: A prospective study of 100 craniotomies","author":"Alexander","year":"1996","journal-title":"Neurosurgery"},{"key":"key-10.4103\/0028-3886.125274-8","first-page":"982","volume-title":"Prospective evaluation of surgical microscope-integrated intraoperative near-infrared indocyanine green videoangiography during aneurysm surgery","author":"Raabe","year":"2005","journal-title":"J Neurosurg"},{"key":"key-10.4103\/0028-3886.125274-9","first-page":"63","volume-title":"Assessment of flow in perforating arteries during intracranial aneurysm surgery using intraoperative near-infrared indocyanine green videoangiography","author":"De","year":"2007","journal-title":"Neurosurgery"},{"key":"key-10.4103\/0028-3886.125274-10","first-page":"114","volume-title":"Immediate and follow-up results for 44 consecutive cases of small (<10 mm) internal carotid artery aneurysms treated with the pipeline embolization device","author":"Lin","year":"2013","journal-title":"Surg Neurol Int","ISSN":"https:\/\/id.crossref.org\/issn\/2152-7806","issn-type":"print"},{"key":"key-10.4103\/0028-3886.125274-11","first-page":"iii11","volume-title":"SILK flow diverter for treatment of intracranial aneurysms: Initial experience and cost analysis","author":"Shankar","year":"2013","journal-title":"J Neurointerv Surg Nov"}],"container-title":["Neurology India"],"original-title":[],"language":"en","deposited":{"date-parts":[[2026,8,13]],"date-time":"2026-08-13T19:23:41Z","timestamp":1786649021000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.ovid.com\/10.4103\/0028-3886.125274"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2013]]},"references-count":11,"journal-issue":{"issue":"6","published-print":{"date-parts":[[2013]]}},"alternative-id":["125274"],"URL":"https:\/\/doi.org\/10.4103\/0028-3886.125274","relation":{},"ISSN":["0028-3886"],"issn-type":[{"value":"0028-3886","type":"print"}],"subject":[],"published":{"date-parts":[[2013]]}}}