{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,8,27]],"date-time":"2026-08-27T14:17:22Z","timestamp":1787840242572,"version":"build-2784847793"},"reference-count":10,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"3","content-domain":{"domain":["lww.com","ovid.com"],"crossmark-restriction":true},"short-container-title":[],"published-print":{"date-parts":[[2022,5]]},"abstract":"<jats:sec>\n                    <jats:title>Background:<\/jats:title>\n                    <jats:p>Careful evaluation of the preoperative imaging for extracranial\u2013intracranial bypass performed for conditions like intracranial stenosis and Moya disease is important. The traditional use of 2D imaging has a significant limitation for neurosurgeons, primarily to determine the optimal location of the recipient artery for performing the surgical bypass. Therefore, many neurosurgeons use 3D angiograms more frequently to overcome these shortcomings.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Materials And Methods:<\/jats:title>\n                    <jats:p>\n                      We performed the preoperative evaluation of the possibility of performing an anastomosis between the superficial temporal artery and the middle cerebral artery (STA\u2013MCA) bypass by synthesizing images of computerized tomography (CT), magnetic resonance imaging (MRI), and digital subtraction angiography (DSA) using Amira\n                      <jats:sup>\u00ae<\/jats:sup>\n                      of 3D visualization analysis software (Thermo Scientific Co.).\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results:<\/jats:title>\n                    <jats:p>The 3D images prepared before surgery using this software showed good agreement with the intraoperative findings.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusion:<\/jats:title>\n                    <jats:p>Preoperative image processing using tools like Amira provide optimal information for good planning and communication for performing STA\u2013MCA bypass and may become a helpful tool.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.4103\/0028-3886.349625","type":"journal-article","created":{"date-parts":[[2023,8,24]],"date-time":"2023-08-24T03:55:57Z","timestamp":1692849357000},"page":"943-947","update-policy":"https:\/\/doi.org\/10.1097\/lww.0000000000001000","source":"Crossref","is-referenced-by-count":2,"title":["Preoperative 3D Image Evaluation of EC\u2013IC Bypass by 3D Visualization Analysis Software Amira\u00ae"],"prefix":"10.4103","volume":"70","author":[{"given":"Riki","family":"Tanaka","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Boon Seng","family":"Liew","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Yasuhiro","family":"Yamada","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Mai","family":"Okubo","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Tomoka","family":"Katayama","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Kento","family":"Sasaki","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Kyosuke","family":"Miyatani","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Fuminari","family":"Komatsu","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Yoko","family":"Kato","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Yuichi","family":"Hirose","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"276","reference":[{"key":"R1-18-20241013","first-page":"524","article-title":"JET study (Japanese EC-IC Bypass Trial)","volume":"64","author":"Ogasawara","year":"2006","journal-title":"Nihon Rinsho"},{"key":"R3-18-20241013","doi-asserted-by":"crossref","first-page":"E20","DOI":"10.3171\/2009.2.FOCUS0917","article-title":"Minimally invasive superficial temporal artery to middle cerebral artery bypass through a minicraniotomy: Benefit of three-dimensional virtual reality planning using magnetic resonance angiography","volume":"26","author":"Fischer","year":"2009","journal-title":"Neurosurg Focus"},{"key":"R4-18-20241013","doi-asserted-by":"crossref","first-page":"11","DOI":"10.3109\/10929089709149079","article-title":"Three-dimensional magnetic resonance angiography in the planning of aneurysm surgery","volume":"2","author":"Melgar","year":"1997","journal-title":"Comput Aided Surg"},{"key":"R5-18-20241013","doi-asserted-by":"crossref","first-page":"6477","DOI":"10.3390\/s130506477","article-title":"3D preoperative planning in the ER with OsiriX\u00ae: when there is no time for neuronavigation","volume":"13","author":"Mandel","year":"2013","journal-title":"Sensors (Basel"},{"key":"R7-18-20241013","doi-asserted-by":"crossref","first-page":"637","DOI":"10.1148\/rg.243035126","article-title":"CT angiography of intracranial aneurysms: A focus on postprocessing","volume":"24","author":"Tomandl","year":"2004","journal-title":"Radiographics"},{"key":"R8-18-20241013","doi-asserted-by":"crossref","first-page":"745","DOI":"10.1148\/radiographics.19.3.g99ma14745","article-title":"Three-dimensional volume rendering of spiral CT data: theory and method","volume":"19","author":"Calhoun","year":"1999","journal-title":"Radiographics"},{"key":"R9-18-20241013","doi-asserted-by":"crossref","first-page":"281","DOI":"10.1515\/bmt-2012-0079","article-title":"Autostereoscopic 3D visualization and image processing system for neurosurgery","volume":"58","author":"Meyer","year":"2013","journal-title":"Biomed Tech (Berl"},{"key":"R10-18-20241013","doi-asserted-by":"crossref","first-page":"E1000","DOI":"10.1097\/BSD.0000000000000477","article-title":"Three-dimensional cross-platform planning for complex spinal procedures: A new method adaptive to different navigation systems","volume":"30","author":"Kosterhon","year":"2017","journal-title":"Clin Spine Surg"},{"key":"R11-18-20241013","doi-asserted-by":"crossref","first-page":"56","DOI":"10.3389\/fsurg.2019.00056","article-title":"Clinical benefits of combining different visualization modalities in neurosurgery","volume":"6","author":"Schebesch","year":"2019","journal-title":"Front Surg"},{"key":"R12-18-20241013","doi-asserted-by":"crossref","first-page":"596167","DOI":"10.3389\/fnana.2020.596167","article-title":"Importance of veins for neurosurgery as landmarks against brain shifting phenomenon: An anatomical and 3D-MPRAGE MR reconstruction of superficial cortical veins","volume":"14","author":"Tomasi","year":"2020","journal-title":"Front Neuroanat"}],"container-title":["Neurology India"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.ovid.com\/10.4103\/0028-3886.349625","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,8,27]],"date-time":"2026-08-27T13:18:11Z","timestamp":1787836691000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.ovid.com\/10.4103\/0028-3886.349625"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2022,5]]},"references-count":10,"journal-issue":{"issue":"3","published-print":{"date-parts":[[2022]]}},"URL":"https:\/\/doi.org\/10.4103\/0028-3886.349625","relation":{},"ISSN":["0028-3886"],"issn-type":[{"value":"0028-3886","type":"print"}],"subject":[],"published":{"date-parts":[[2022,5]]}}}