{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,27]],"date-time":"2026-10-27T23:55:12Z","timestamp":1793145312612,"version":"4.5.0"},"reference-count":26,"publisher":"King Faisal Specialist Hospital and Research Centre","issue":"3","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Annals of Saudi Medicine"],"published-print":{"date-parts":[[2011,5]]},"DOI":"10.4103\/0256-4947.81542","type":"journal-article","created":{"date-parts":[[2011,5,24]],"date-time":"2011-05-24T10:53:43Z","timestamp":1306234423000},"page":"294-297","source":"Crossref","is-referenced-by-count":61,"title":["Percutaneous vertebroplasty complications"],"prefix":"10.5144","volume":"31","author":[{"given":"Nizar A.","family":"Al-Nakshabandi","sequence":"first","affiliation":[{"name":"From the Department of Radiology and Medical Imaging, College of Medicine, King Saud University, Riyadh, Saudi Arabia"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"3134","reference":[{"key":"e_1_3_1_2_2","doi-asserted-by":"crossref","first-page":"311","DOI":"10.1148\/radiographics.18.2.9536480","article-title":"Percutanous Vertebroplasty: State of art","volume":"18","author":"Cotten A","year":"1998","journal-title":"RadioGraphics"},{"key":"e_1_3_1_3_2","doi-asserted-by":"crossref","first-page":"1001","DOI":"10.1016\/S1051-0443(07)61584-X","article-title":"Transient arterial hypotension induced by polymethylmethacrylate Injection during percutanous vertebroplasty","volume":"12","author":"Vasconcelos C","year":"2001","journal-title":"J Vascu Interv Radiol"},{"key":"e_1_3_1_4_2","first-page":"175","article-title":"Vertebroplasty: Cement leakage into the disc increases the risk of new fracture of adjacent vertebral body","volume":"25","author":"Lin EP","year":"2004","journal-title":"AJNR Am J Neuroradiol"},{"key":"e_1_3_1_5_2","doi-asserted-by":"crossref","first-page":"121","DOI":"10.1148\/radiol.2231010234","article-title":"Percutaneous vertebroplasty for severe osteoporotic vertebral body compression fractures","volume":"223","author":"Peh WC","year":"2002","journal-title":"Radiology"},{"key":"e_1_3_1_6_2","first-page":"2120","article-title":"Is insufficient use of polymethylmethacrylate a cause for vertebroplasty failure necessitating repeat vertebroplasty?","volume":"24","author":"Gilula L","year":"2003","journal-title":"AJNR Am J Neuroradiol"},{"key":"e_1_3_1_7_2","first-page":"56","article-title":"Dose-dependent epidural leakage of polymethylmethacrylate after percutaneous vertebroplasty in patients with osteoporotic vertebral compression fractures","volume":"96","author":"Ryu KS","year":"2002","journal-title":"J Neurosurg"},{"key":"e_1_3_1_8_2","first-page":"1897","article-title":"Percutaneous polymethylmethacrylate vertebroplasty in the treatment of osteoporotic vertebral body compression fractures: Technical aspects","volume":"18","author":"Jensen ME","year":"1997","journal-title":"AJNR Am J Neuroradiol"},{"key":"e_1_3_1_9_2","doi-asserted-by":"crossref","first-page":"65","DOI":"10.1053\/j.sult.2005.02.003","article-title":"Complications of vertebroplasty and their prevention","volume":"26","author":"Laredo JD","year":"2005","journal-title":"Semin Ultrasound CT MR"},{"key":"e_1_3_1_10_2","doi-asserted-by":"crossref","first-page":"119","DOI":"10.1148\/radiol.2261011911","article-title":"Occurrence of new vertebral body fracture after percutaneous vertebroplasty in patients with osteoporosis","volume":"226","author":"Uppin AA","year":"2003","journal-title":"Radiology"},{"key":"e_1_3_1_11_2","first-page":"149","volume-title":"Echecs CT complications de Ia chirurgie du rachis: Chirurgie de reprise","author":"Chiras J","year":"1995"},{"key":"e_1_3_1_12_2","doi-asserted-by":"crossref","first-page":"E209","DOI":"10.1097\/00007632-200405150-00023","article-title":"Serious pyogenic spondylitis following vertebroplasty- a case report","volume":"29","author":"Yu SW","year":"2004","journal-title":"Spine"},{"key":"e_1_3_1_13_2","first-page":"525","article-title":"Percutanous vertebroplasty for osteolytic metastasis and myeloma","volume":"200","author":"Cotten A","year":"1996","journal-title":"Radiology"},{"key":"e_1_3_1_14_2","doi-asserted-by":"crossref","first-page":"E300","DOI":"10.1097\/00007632-200107010-00021","article-title":"Root and spinal cord compression from methylmethacrylate vertebroplasty","volume":"26","author":"Ratliff J","year":"2001","journal-title":"Spine"},{"key":"e_1_3_1_15_2","doi-asserted-by":"crossref","first-page":"879","DOI":"10.1590\/S0004-282X2004000500027","article-title":"Paraplegia complicating percutanous vertebroplasty for osteoporotic vertebral fracture: Case report","volume":"62","author":"Lopes NM","year":"2004","journal-title":"Arq Neuropsiquiatr"},{"key":"e_1_3_1_16_2","first-page":"45","article-title":"Percutanous vertebroplasty surgey; techniques and indications","volume":"24","author":"Chiras J","year":"1997","journal-title":"J Neuroradiol"},{"key":"e_1_3_1_17_2","doi-asserted-by":"crossref","first-page":"E416","DOI":"10.1097\/00007632-200210010-00021","article-title":"Pulmonary embolism of polymethylmethacrylate after percutaneous vertebroplasty: A report of three cases","volume":"27","author":"Jang JS","year":"2002","journal-title":"Spine"},{"key":"e_1_3_1_18_2","doi-asserted-by":"crossref","first-page":"1097","DOI":"10.2214\/ajr.183.4.1831097","article-title":"Pulmonary embolism of polymethyl methacrylate during percutaneous vertebroplasty and kyphoplasty","volume":"183","author":"Choe DH","year":"2004","journal-title":"AJR Am J Roentgenol"},{"key":"e_1_3_1_19_2","first-page":"343","article-title":"Fatal fat embolism after vertebroplasty: Identification of the high-risk patient","volume":"27","author":"Syed MI","year":"2006","journal-title":"AJNR AM J Neuroradiol"},{"key":"e_1_3_1_20_2","doi-asserted-by":"crossref","first-page":"E294","DOI":"10.1097\/01.BRS.0000131211.87594.B0","article-title":"Acute respiratory distress syndrome associated with pulmonary cement embolism following percutaneous vertebroplasty with polymethylmethacrylate","volume":"29","author":"Yoo KH","year":"2004","journal-title":"Spine"},{"key":"e_1_3_1_21_2","doi-asserted-by":"crossref","first-page":"E416","DOI":"10.1097\/00007632-200210010-00021","article-title":"Pulmonary embolism of polymethylmethacrylate after percutaneous vertebroplasty: A report of three cases","volume":"27","author":"Jang JS","year":"2002","journal-title":"Spine"},{"key":"e_1_3_1_22_2","doi-asserted-by":"crossref","first-page":"E294","DOI":"10.1097\/01.BRS.0000131211.87594.B0","article-title":"Acute respiratory distress syndrome associated with pulmonary cement embolism following percutaneous vertebroplasty with polymethylmethacrylate","volume":"29","author":"Yoo KY","year":"2004","journal-title":"Spine"},{"key":"e_1_3_1_23_2","doi-asserted-by":"crossref","first-page":"1245","DOI":"10.2214\/AJR.04.1443","article-title":"Cardiac perforation caused by acrylic cement: A rare complication of percutaneous vertebroplasty","volume":"185","author":"Kim SY","year":"2005","journal-title":"Am J Roentgenol"},{"key":"e_1_3_1_24_2","doi-asserted-by":"crossref","first-page":"315","DOI":"10.1097\/00000542-200008000-00006","article-title":"Intraoperative cerebral arterial embolization during total hip arthroplasty","volume":"93","author":"Edmonds CR","year":"2000","journal-title":"Anesthesiology"},{"key":"e_1_3_1_25_2","doi-asserted-by":"crossref","first-page":"409","DOI":"10.1302\/0301-620X.76B3.8175843","article-title":"Echocardiography of transatrial embolism during cemented and uncemented hemiarthroplasty of the hip","volume":"76","author":"Christie J","year":"1994","journal-title":"J Bone Joint Surg Br"},{"key":"e_1_3_1_26_2","doi-asserted-by":"crossref","first-page":"902","DOI":"10.1148\/radiol.2283030235","article-title":"Cardiovascular Collapse and Death during Vertebroplasty [letter]","volume":"228","author":"Childers JC","year":"2003","journal-title":"Radiology"},{"key":"e_1_3_1_27_2","doi-asserted-by":"crossref","first-page":"409","DOI":"10.1016\/j.ocl.2006.05.001","article-title":"Current concepts and techniques in percutanous vertebroplasty","volume":"37","author":"Heran MK","year":"2006","journal-title":"Orthop Clin North Am"}],"container-title":["Annals of Saudi Medicine"],"original-title":[],"language":"en","deposited":{"date-parts":[[2019,6,2]],"date-time":"2019-06-02T07:11:26Z","timestamp":1559459486000},"score":1,"resource":{"primary":{"URL":"http:\/\/www.annsaudimed.net\/doi\/10.4103\/0256-4947.81542"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2011,5]]},"references-count":26,"journal-issue":{"issue":"3","published-print":{"date-parts":[[2011,5]]}},"alternative-id":["10.4103\/0256-4947.81542"],"URL":"https:\/\/doi.org\/10.4103\/0256-4947.81542","relation":{},"ISSN":["0256-4947","0975-4466"],"issn-type":[{"value":"0256-4947","type":"print"},{"value":"0975-4466","type":"electronic"}],"subject":[],"published":{"date-parts":[[2011,5]]}}}