{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,8,26]],"date-time":"2026-08-26T16:20:47Z","timestamp":1787761247350,"version":"build-2784847793"},"reference-count":16,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"5","content-domain":{"domain":["lww.com","ovid.com"],"crossmark-restriction":true},"short-container-title":[],"published-print":{"date-parts":[[2016,5]]},"abstract":"<jats:sec>\n                    <jats:title>Aim of study:<\/jats:title>\n                    <jats:p>The aim of this study is to assess wavefront aberration and contrast sensitivity (CS) after implantation of foldable iris claw \u2013 artiflex- and rigid iris claw \u2013 artisan- phakic intraocular lenses (pIOLs).<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Materials and Methods:<\/jats:title>\n                    <jats:p>A nonrandomized prospective comparative case study was performed on 57 eyes; of which, 54 were myopia and 3 were hyperopia. Twenty-four patients had artisan pIOL implantation and 33 had artiflex pIOL implantation. Higher-order aberration (HOA) and CS were obtained 1 year after surgery.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results:<\/jats:title>\n                    <jats:p>\n                      Total HOA in artisan group was greater than artiflex group (\n                      <jats:italic toggle=\"yes\">P<\/jats:italic>\n                      = 0.044) with a mean HOA of 0.44 \u00b1 0.15 root mean square (RMS) for artisan and 0.35 \u00b1 0.15 RMS for artiflex. Although, there were no significant differences in the vertical trefoil, vertical coma, horizontal trefoil, horizontal coma, secondary astigmatism, quatrefoil, and fourth order spherical aberration in two groups. CS in mesopic conditions was better in artiflex-treated eyes at three spatial frequencies of 6, 12, and 18 cycles per degree (cpd) (\n                      <jats:italic toggle=\"yes\">P<\/jats:italic>\n                      = 0.003,\n                      <jats:italic toggle=\"yes\">P<\/jats:italic>\n                      = 0.007, and\n                      <jats:italic toggle=\"yes\">P<\/jats:italic>\n                      = 0.00, respectively), and no significant difference was seen between two lenses at 3 cpd.\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusion:<\/jats:title>\n                    <jats:p>Although the components of HOA were not significantly different between two groups, total HOA was higher in artisan group, which may be due to the slight differences in each component, increasing the HOA as a total. CS was significantly better in artiflex group.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.4103\/0301-4738.185611","type":"journal-article","created":{"date-parts":[[2016,8,3]],"date-time":"2016-08-03T08:39:10Z","timestamp":1470213550000},"page":"382-386","update-policy":"https:\/\/doi.org\/10.1097\/lww.0000000000001000","source":"Crossref","is-referenced-by-count":3,"title":["Wavefront aberration and contrast sensitivity after implantation of foldable and rigid iris claw phakic intraocular lenses: Artiflex versus artisan"],"prefix":"10.4103","volume":"64","author":[{"given":"Faroogh","family":"Parsipour","sequence":"first","affiliation":[{"name":"Isfahan Eye Research Center, Feiz Hospital, Isfahan University of Medical Sciences, Isfahan, Iran"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Hassan","family":"Razmju","sequence":"additional","affiliation":[{"name":"Isfahan Eye Research Center, Feiz Hospital, Isfahan University of Medical Sciences, Isfahan, Iran"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Fatima","family":"Khatavi","sequence":"additional","affiliation":[{"name":"Isfahan Eye Research Center, Feiz Hospital, Isfahan University of Medical Sciences, Isfahan, Iran"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Maryam","family":"Panahi","sequence":"additional","affiliation":[{"name":"Isfahan Eye Research Center, Feiz Hospital, Isfahan University of Medical Sciences, Isfahan, Iran"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Alireza","family":"Nouralishahi","sequence":"additional","affiliation":[{"name":"Isfahan Eye Research Center, Feiz Hospital, Isfahan University of Medical Sciences, Isfahan, Iran"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Alireza","family":"Peyman","sequence":"additional","affiliation":[{"name":"Department of Ophthalmology, Isfahan Eye Research Center, Isfahan University of Medical Sciences, Isfahan, Iran"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"276","reference":[{"key":"R1-20251013","doi-asserted-by":"crossref","first-page":"1133","DOI":"10.1016\/j.ophtha.2006.09.029","article-title":"Long-term study of Artisan phakic intraocular lens implantation for the correction of moderate to high myopia: Ten-year follow-up results","volume":"114","author":"Tahzib","year":"2007","journal-title":"Ophthalmology"},{"key":"R2-20251013","doi-asserted-by":"crossref","first-page":"1976","DOI":"10.1016\/j.jcrs.2010.08.014","article-title":"Phakic intraocular lenses part 1: Historical overview, current models, selection criteria, and surgical techniques","volume":"36","author":"G\u00fcell","year":"2010","journal-title":"J Cataract Refract Surg"},{"key":"R3-20251013","doi-asserted-by":"crossref","first-page":"31","DOI":"10.1016\/j.ajo.2006.01.088","article-title":"Functional outcome and patient satisfaction after Artisan phakic intraocular lens implantation for the correction of myopia","volume":"142","author":"Tahzib","year":"2006","journal-title":"Am J Ophthalmol"},{"key":"R4-20251013","doi-asserted-by":"crossref","first-page":"33","DOI":"10.1016\/j.jcrs.2003.11.023","article-title":"Phakic intraocular lenses to correct high myopia: Adatomed, Staar, and Artisan","volume":"30","author":"Menezo","year":"2004","journal-title":"J Cataract Refract Surg"},{"key":"R5-20251013","doi-asserted-by":"crossref","first-page":"321","DOI":"10.1038\/eye.2011.292","article-title":"Five-year follow-up after anterior iris-fixated intraocular lens implantation in phakic eyes to correct high myopia","volume":"26","author":"Yuan","year":"2012","journal-title":"Eye (Lond)"},{"key":"R6-20251013","first-page":"1622","article-title":"A randomized paired eye comparison of two techniques for treating moderately high myopia: LASIK and artisan phakic lens","volume":"6420","author":"Malecaze","year":"2002"},{"key":"R7-20251013","doi-asserted-by":"crossref","first-page":"505","DOI":"10.1586\/eop.11.57","article-title":"Phakic intraocular lenses for high myopia and high hyperopia","volume":"6","author":"Kwitko","year":"2011","journal-title":"Expert Rev Ophthalmol"},{"key":"R8-20251013","doi-asserted-by":"crossref","first-page":"1913","DOI":"10.1016\/j.jcrs.2008.07.014","article-title":"Higher-order aberrations after implantation of iris-fixated rigid or foldable phakic intraocular lenses","volume":"34","author":"Tahzib","year":"2008","journal-title":"J Cataract Refract Surg"},{"key":"R9-20251013","doi-asserted-by":"crossref","first-page":"114","DOI":"10.1016\/j.jcrs.2007.08.037","article-title":"Position of rigid and foldable iris-fixated myopic phakic intraocular lenses evaluated by Scheimpflug photography","volume":"34","author":"Kohnen","year":"2008","journal-title":"J Cataract Refract Surg"},{"key":"R10-20251013","doi-asserted-by":"crossref","first-page":"1163","DOI":"10.1016\/S0886-3350(00)00545-9","article-title":"Multicenter study of the Artisan phakic intraocular lens","volume":"26","author":"Budo","year":"2000","journal-title":"J Cataract Refract Surg"},{"key":"R11-20251013","doi-asserted-by":"crossref","first-page":"1110","DOI":"10.1016\/j.ophtha.2006.02.017","article-title":"The influence of incision-induced astigmatism and axial lens position on the correction of myopic astigmatism with the Artisan toric phakic intraocular lens","volume":"113","author":"Bartels","year":"2006","journal-title":"Ophthalmology"},{"key":"R12-20251013","doi-asserted-by":"crossref","first-page":"909","DOI":"10.1016\/j.ajo.2006.07.021","article-title":"Iris-supported phakic lenses (rigid vs foldable version) for treating moderately high myopia: Randomized paired eye comparison","volume":"142","author":"Coullet","year":"2006","journal-title":"Am J Ophthalmol"},{"key":"R13-20251013","first-page":"620","article-title":"Correction of high myopia with foldable Artiflex Phakic intraocular lenses: 1 year follow-up results","volume":"51","author":"Hashemi","year":"2013","journal-title":"Acta Med Iran"},{"key":"R14-20251013","doi-asserted-by":"crossref","first-page":"427","DOI":"10.4103\/2008-322X.150805","article-title":"Comparison of three phakic intraocular lenses for correction of myopia","volume":"9","author":"Karimian","year":"2014","journal-title":"J Ophthalmic Vis Res"},{"key":"R15-20251013","first-page":"21","article-title":"Outcome of iris-claw phakic intraocular lens implantation for high myopia; a subspecialty training setting","volume":"21","author":"Siatiri","year":"2009","journal-title":"Iran J Ophthalmol"},{"key":"R16-20251013","doi-asserted-by":"crossref","first-page":"1911","DOI":"10.1016\/j.jcrs.2009.05.054","article-title":"Influence of optic quality on contrast sensitivity and visual acuity in eyes with a rigid or flexible phakic intraocular lens","volume":"35","author":"Peris-Mart\u00ednez","year":"2009","journal-title":"J Cataract Refract Surg"}],"container-title":["Indian Journal of Ophthalmology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.ovid.com\/02223307-201664050-00009","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,8,26]],"date-time":"2026-08-26T15:29:23Z","timestamp":1787758163000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.ovid.com\/02223307-201664050-00009"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2016,5]]},"references-count":16,"journal-issue":{"issue":"5","published-print":{"date-parts":[[2016]]}},"URL":"https:\/\/doi.org\/10.4103\/0301-4738.185611","relation":{},"ISSN":["0301-4738","1998-3689"],"issn-type":[{"value":"0301-4738","type":"print"},{"value":"1998-3689","type":"electronic"}],"subject":[],"published":{"date-parts":[[2016,5]]},"assertion":[{"value":"2015-06-26","name":"received","label":"Received","group":{"name":"publication_history","label":"Publication History"}},{"value":"2016-03-23","name":"accepted","label":"Accepted","group":{"name":"publication_history","label":"Publication History"}}]}}