{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,8,27]],"date-time":"2026-08-27T14:34:15Z","timestamp":1787841255710,"version":"build-2784847793"},"reference-count":13,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"1","content-domain":{"domain":["lww.com","ovid.com"],"crossmark-restriction":true},"short-container-title":[],"published-print":{"date-parts":[[2017,1]]},"abstract":"<jats:sec>\n                    <jats:title>Context:<\/jats:title>\n                    <jats:p>Selecting an appropriate size double-lumen tube (DLT) for one-lung ventilation has always been a challenge as most choose it based on experience or using the existing guidelines based on gender and height.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Aims:<\/jats:title>\n                    <jats:p>The aim of this study was to determine if the appropriate choice of this tube could be based on the patients\u2019 height, weight, tracheal diameter (TD), or the left main stem bronchus diameter (LMBD) and also to determine the relationship between height and depth of insertion among Asians.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Subjects and Methods:<\/jats:title>\n                    <jats:p>This was a retrospective review of 179 patients who were intubated with a left-sided DLT and also had a posterior-anterior view of a digital chest radiograph for tracheal and left main bronchus diameter measurements. Additional data collected included patients\u2019 demographics and DLT size used.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results:<\/jats:title>\n                    <jats:p>\n                      There were 123 (68.7%) males and 56 (31.3%) females with an overall mean age of 33.3 \u00b1 16.3 years. Majority of the males (48.8%) used a size 39 Fr while females (46.4%) used a 35 Fr. There were weak correlations between DLT size with height (male:\n                      <jats:italic toggle=\"yes\">R<\/jats:italic>\n                      <jats:sup>2<\/jats:sup>\n                      = 0.222; female:\n                      <jats:italic toggle=\"yes\">R<\/jats:italic>\n                      <jats:sup>2<\/jats:sup>\n                      = 0.193), DLT size with weight (male:\n                      <jats:italic toggle=\"yes\">R<\/jats:italic>\n                      <jats:sup>2<\/jats:sup>\n                      = 0.109; female:\n                      <jats:italic toggle=\"yes\">R<\/jats:italic>\n                      <jats:sup>2<\/jats:sup>\n                      = 0.211), DLT size with TD (male:\n                      <jats:italic toggle=\"yes\">R<\/jats:italic>\n                      <jats:sup>2<\/jats:sup>\n                      = 0.027); female:\n                      <jats:italic toggle=\"yes\">R<\/jats:italic>\n                      <jats:sup>2<\/jats:sup>\n                      = 0.016), and DLT size with LMBD (male:\n                      <jats:italic toggle=\"yes\">R<\/jats:italic>\n                      <jats:sup>2<\/jats:sup>\n                      = 0.222; female:\n                      <jats:italic toggle=\"yes\">R<\/jats:italic>\n                      <jats:sup>2<\/jats:sup>\n                      = 0.193). There was a good correlation between depth of DLT inserted with patient's height for both genders.\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusion:<\/jats:title>\n                    <jats:p>The appropriate size of the left-sided DLT could not be predicted based on patients\u2019 height, weight, tracheal or left main bronchus diameter alone in Asians; however, the depth of insertion of the tube was dependent on the height in both genders.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.4103\/0971-9784.197824","type":"journal-article","created":{"date-parts":[[2017,1,10]],"date-time":"2017-01-10T22:47:13Z","timestamp":1484088433000},"page":"28-32","update-policy":"https:\/\/doi.org\/10.1097\/lww.0000000000001000","source":"Crossref","is-referenced-by-count":20,"title":["Selection of an Appropriate Left-sided Double-lumen Tube Size for One-lung Ventilation among Asians"],"prefix":"10.4103","volume":"20","author":[{"given":"Siti Salwani","family":"Ideris","sequence":"first","affiliation":[{"name":"From the Department of Anaesthesiology and Intensive Care, Universiti Kebangsaan Malaysia Medical Centre, Kuala Lumpur, Malaysia"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Muhamad Rahimi","family":"Che Hassan","sequence":"additional","affiliation":[{"name":"From the Department of Anaesthesiology and Intensive Care, Universiti Kebangsaan Malaysia Medical Centre, Kuala Lumpur, Malaysia"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Mohd. Ramzisham","family":"Abdul Rahman","sequence":"additional","affiliation":[{"name":"Department of Surgery, Cardiothoracic Unit, Universiti Kebangsaan Malaysia Medical Centre, Kuala Lumpur, Malaysia"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Joanna Su Min","family":"Ooi","sequence":"additional","affiliation":[{"name":"From the Department of Anaesthesiology and Intensive Care, Universiti Kebangsaan Malaysia Medical Centre, Kuala Lumpur, Malaysia"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"276","reference":[{"key":"R1-20250920","doi-asserted-by":"crossref","first-page":"1295","DOI":"10.1097\/00000542-200211000-00036","article-title":"Current techniques for perioperative lung isolation in adults","volume":"97","author":"Campos","year":"2002","journal-title":"Anesthesiology"},{"key":"R2-20250920","doi-asserted-by":"crossref","first-page":"R1","DOI":"10.1007\/BF03028172","article-title":"Lung isolation in thoracic anesthesia, state of the art","volume":"48","author":"Slinger","year":"2001","journal-title":"Can J Anesth"},{"key":"R3-20250920","doi-asserted-by":"crossref","first-page":"287","DOI":"10.1016\/S1053-0770(03)00058-2","article-title":"A view of and through double-lumen tubes","volume":"17","author":"Slinger","year":"2003","journal-title":"J Cardiothorac Vasc Anesth"},{"key":"R4-20250920","doi-asserted-by":"crossref","first-page":"267","DOI":"10.1016\/j.jclinane.2004.07.008","article-title":"Tracheal width and left double-lumen tube size: A formula to estimate left-bronchial width","volume":"17","author":"Brodsky","year":"2005","journal-title":"J Clin Anesth"},{"key":"R5-20250920","first-page":"861","article-title":"Tracheal diameter predicts double-lumen tube size: A method for selecting left double-lumen tubes","volume":"82","author":"Brodsky","year":"1996","journal-title":"Anesth Analg"},{"key":"R6-20250920","doi-asserted-by":"crossref","first-page":"59","DOI":"10.1177\/0310057X0503300109","article-title":"A new technique to determine the size of double-lumen endobronchial tubes by two perpendicularly measured bronchial diameters","volume":"33","author":"Jeon","year":"2005","journal-title":"Anaesth Intensive Care"},{"key":"R7-20250920","doi-asserted-by":"crossref","first-page":"119","DOI":"10.1016\/S1053-0770(05)80180-6","article-title":"The relationship between left mainstem bronchial diameter and patient size","volume":"9","author":"Hannallah","year":"1995","journal-title":"J Cardiothorac Vasc Anesth"},{"key":"R8-20250920","doi-asserted-by":"crossref","first-page":"101","DOI":"10.1378\/chest.130.1.101","article-title":"Measurement of left mainstem bronchus using multiplane CT reconstructions and relationship between patient characteristics or tracheal diameters and left bronchial diameters","volume":"130","author":"Olivier","year":"2006","journal-title":"Chest"},{"key":"R9-20250920","doi-asserted-by":"crossref","first-page":"168","DOI":"10.1016\/S1053-0770(97)90208-1","article-title":"Evaluation of an approach to choosing a left double-lumen tube size based on chest computed tomographic scan measurement of left mainstem bronchial diameter","volume":"11","author":"Hannallah","year":"1997","journal-title":"J Cardiothorac Vasc Anesth"},{"key":"R10-20250920","doi-asserted-by":"crossref","first-page":"540","DOI":"10.1177\/0310057X0002800510","article-title":"Estimating the diameter of the left main bronchus","volume":"28","author":"Hampton","year":"2000","journal-title":"Anaesth Intensive Care"},{"key":"R11-20250920","first-page":"210","article-title":"The dimensional interrelationships of the major components of the human tracheobronchial tree","volume":"105","author":"Jesseph","year":"1957","journal-title":"Surg Gynecol Obstet"},{"key":"R12-20250920","doi-asserted-by":"crossref","first-page":"302","DOI":"10.1213\/00000539-199902000-00014","article-title":"Predicting the size of a double-lumen endobronchial tube using computed tomographic scan measurements of the left main bronchus diameter","volume":"88","author":"Chow","year":"1999","journal-title":"Anesth Analg"},{"key":"R13-20250920","doi-asserted-by":"crossref","first-page":"570","DOI":"10.1213\/00000539-199111000-00010","article-title":"Depth of placement of left double-lumen endobronchial tubes","volume":"73","author":"Brodsky","year":"1991","journal-title":"Anesth Analg"}],"container-title":["Annals of Cardiac Anaesthesia"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.ovid.com\/00660469-201720010-00006","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,8,27]],"date-time":"2026-08-27T13:47:36Z","timestamp":1787838456000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.ovid.com\/00660469-201720010-00006"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2017,1]]},"references-count":13,"journal-issue":{"issue":"1","published-print":{"date-parts":[[2017]]}},"URL":"https:\/\/doi.org\/10.4103\/0971-9784.197824","relation":{},"ISSN":["0971-9784","0974-5181"],"issn-type":[{"value":"0971-9784","type":"print"},{"value":"0974-5181","type":"electronic"}],"subject":[],"published":{"date-parts":[[2017,1]]},"assertion":[{"value":"2016-08-01","name":"received","label":"Received","group":{"name":"publication_history","label":"Publication History"}},{"value":"2016-12-01","name":"accepted","label":"Accepted","group":{"name":"publication_history","label":"Publication History"}}]}}