{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,8,13]],"date-time":"2026-08-13T19:36:24Z","timestamp":1786649784185,"version":"build-2736575974"},"reference-count":14,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"1","content-domain":{"domain":["lww.com","ovid.com"],"crossmark-restriction":true},"short-container-title":[],"published-print":{"date-parts":[[2017,1]]},"abstract":"<jats:sec>\n                    <jats:title>Introduction:<\/jats:title>\n                    <jats:p>\n                      Many factors, such as PRESAGE\n                      <jats:sup>\u00ae<\/jats:sup>\n                      composition, dose rate, energy, and type of radiation, temperature, etc., may effect on PRESAGE\n                      <jats:sup>\u00ae<\/jats:sup>\n                      dosimeter response. The aim of this study was investigating the effect of temperature variation on response of PRESAGE\n                      <jats:sup>\u00ae<\/jats:sup>\n                      solid dosimeter.\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Materials and Methods:<\/jats:title>\n                    <jats:p>\n                      In this study, a PRESAGE\n                      <jats:sup>\u00ae<\/jats:sup>\n                      solid detector was fabricated. Ninety-four percent weight polyurethane, 5% weight carbon tetrachloride, and 1% weight leucomalachite green were used. Radiological and physical characteristics of PRESAGEs\n                      <jats:sup>\u00ae<\/jats:sup>\n                      , such as mass density, electron density, and effective number atomic were obtained and compared with water. Response of PRESAGE\n                      <jats:sup>\u00ae<\/jats:sup>\n                      dosimeter in temperatures \u22124, 10, 25, 35, 45, 55, 65, 75, 85, and 90\u00b0C was evaluated. In addition, the absorption peak at various temperatures was investigated.\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results:<\/jats:title>\n                    <jats:p>\n                      The results showed that the absorption peak at different temperatures was in the range of 630\u2013635 nm. For temperatures below 75\u00b0C, the results indicated that temperature variation has no effect on the response of PRESAGE\n                      <jats:sup>\u00ae<\/jats:sup>\n                      dosimeter whereas at the temperatures &gt;75\u00b0C, temperature variation has an effect on PRESAGE\n                      <jats:sup>\u00ae<\/jats:sup>\n                      dosimeter response.\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusion:<\/jats:title>\n                    <jats:p>\n                      The finding showed that temperature changes have not impact on the absorption peak. In addition, the results related to the effect of temperature variation on the response of PRESAGE\n                      <jats:sup>\u00ae<\/jats:sup>\n                      dosimeter showed that in the range of clinical applications (temperatures below 75\u00b0C), temperature variation has no effect on PRESAGE\n                      <jats:sup>\u00ae<\/jats:sup>\n                      dosimeter response.\n                    <\/jats:p>\n                  <\/jats:sec>","DOI":"10.4103\/0973-1482.199389","type":"journal-article","created":{"date-parts":[[2017,5,16]],"date-time":"2017-05-16T10:27:38Z","timestamp":1494930458000},"page":"118-121","update-policy":"https:\/\/doi.org\/10.1097\/lww.0000000000001000","source":"Crossref","is-referenced-by-count":6,"title":["Evaluation of the effect of temperature variation on response of PRESAGE\u00ae dosimeter"],"prefix":"10.4103","volume":"13","author":[{"given":"Bagher","family":"Farhood","sequence":"first","affiliation":[{"name":"Department of Medical Physics and Biomedical Engineering, School of Medicine, Tehran University of Medical Sciences, Tehran, Iran"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Davood","family":"Khezerloo","sequence":"additional","affiliation":[{"name":"Department of Medical Physics and Biomedical Engineering, School of Medicine, Tehran University of Medical Sciences, Tehran, Iran"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Tohid Morteza","family":"Zadeh","sequence":"additional","affiliation":[{"name":"Department of Medical Physics and Biomedical Engineering, School of Medicine, Tehran University of Medical Sciences, Tehran, Iran"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Hassan Ali","family":"Nedaie","sequence":"additional","affiliation":[{"name":"Department of Medical Physics and Biomedical Engineering, School of Medicine, Tehran University of Medical Sciences, Tehran, Iran"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Daryoosh","family":"Hamrahi","sequence":"additional","affiliation":[{"name":"Sadra Radiotherapy Center, Qom, Iran"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Najimeh","family":"Khezerloo","sequence":"additional","affiliation":[{"name":"Department of Radiology, Imam Hospital, Tabriz University of Medical Sciences, Tabriz, Iran"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"276","reference":[{"key":"R3-20260109","first-page":"1","article-title":"Literature review on IMRT and VMAT for prostate cancer","volume":"2","author":"Gautam","year":"2014","journal-title":"Am J Cancer Rev"},{"key":"R4-20260109","doi-asserted-by":"crossref","first-page":"2143","DOI":"10.1088\/0031-9155\/44\/9\/303","article-title":"Assessment of new small-field detectors against standard-field detectors for practical stereotactic beam data acquisition","volume":"44","author":"McKerracher","year":"1999","journal-title":"Phys Med Biol"},{"key":"R5-20260109","doi-asserted-by":"crossref","first-page":"206","DOI":"10.1118\/1.2815356","article-title":"Small fields: Nonequilibrium radiation dosimetry","volume":"35","author":"Das","year":"2008","journal-title":"Med Phys"},{"key":"R6-20260109","first-page":"81","article-title":"Dose measurements in small fields","volume":"1","author":"Wuerfel","year":"2013","journal-title":"Med Phys"},{"key":"R7-20260109","doi-asserted-by":"crossref","first-page":"393","DOI":"10.1016\/j.apradiso.2008.06.026","article-title":"The history and principles of chemical dosimetry for 3-D radiation fields: Gels, polymers and plastics","volume":"67","author":"Doran","year":"2009","journal-title":"Appl Radiat Isot"},{"key":"R8-20260109","doi-asserted-by":"crossref","first-page":"919","DOI":"10.1259\/bjr.73.873.11064643","article-title":"Radiation dosimetry using polymer gels: Methods and applications","volume":"73","author":"McJury","year":"2000","journal-title":"Br J Radiol"},{"key":"R9-20260109","doi-asserted-by":"crossref","first-page":"31","DOI":"10.1016\/0020-708X(58)90053-X","article-title":"Radiation polymerization dosimetry","volume":"3","author":"Hoecker","year":"1958","journal-title":"Int J Appl Radiat Isot"},{"key":"R10-20260109","doi-asserted-by":"crossref","first-page":"172","DOI":"10.1088\/1742-6596\/3\/1\/020","article-title":"A new approach to radiochromic three-dimensional dosimetry-polyurethane","volume":"3","author":"Adamovics","year":"2004","journal-title":"J Phys Conf Ser"},{"key":"R11-20260109","doi-asserted-by":"crossref","first-page":"107","DOI":"10.1093\/rpd\/nci555","article-title":"Characterisation of PRESAGE \u2122: A new 3-D radiochromic solid polymer dosemeter for ionising radiation","volume":"120","author":"Adamovics","year":"2006","journal-title":"Radiat Prot Dosimetry"},{"key":"R14-20260109","doi-asserted-by":"crossref","first-page":"660","DOI":"10.1016\/j.radphyschem.2009.11.014","article-title":"Temperature dependence on the dose response of the Fricke-gelatin-xylenol orange gel dosimeter","volume":"79","author":"Davies","year":"2010","journal-title":"Radiat Phys Chem"},{"key":"R15-20260109","doi-asserted-by":"crossref","first-page":"1435","DOI":"10.1088\/0031-9155\/47\/9\/301","article-title":"Temperature increases associated with polymerization of irradiated PAG dosimeters","volume":"47","author":"Salomons","year":"2002","journal-title":"Phys Med Biol"},{"key":"R16-20260109","doi-asserted-by":"crossref","first-page":"2370","DOI":"10.1118\/1.1410124","article-title":"Temperature dependence of polymer-gel dosimeter nuclear magnetic resonance response","volume":"28","author":"Spevacek","year":"2001","journal-title":"Med Phys"},{"key":"R17-20260109","doi-asserted-by":"crossref","first-page":"012100","DOI":"10.1088\/1742-6596\/250\/1\/012100","article-title":"Effect of irradiation and storage temperature on PRESAGE \u2122 dose response","volume":"250","author":"Skyt","year":"2010","journal-title":"J Phys Conf Ser"},{"key":"R19-20260109","doi-asserted-by":"crossref","first-page":"1338","DOI":"10.1118\/1.2192888","article-title":"Characterization of a new radiochromic three-dimensional dosimeter","volume":"33","author":"Guo","year":"2006","journal-title":"Med Phys"}],"container-title":["Journal of Cancer Research and Therapeutics"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.ovid.com\/01363817-201713010-00021","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,8,13]],"date-time":"2026-08-13T18:58:22Z","timestamp":1786647502000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.ovid.com\/01363817-201713010-00021"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2017,1]]},"references-count":14,"journal-issue":{"issue":"1","published-print":{"date-parts":[[2017]]}},"URL":"https:\/\/doi.org\/10.4103\/0973-1482.199389","relation":{},"ISSN":["0973-1482","1998-4138"],"issn-type":[{"value":"0973-1482","type":"print"},{"value":"1998-4138","type":"electronic"}],"subject":[],"published":{"date-parts":[[2017,1]]}}}