{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,8,18]],"date-time":"2026-08-18T16:43:44Z","timestamp":1787071424187,"version":"build-2736575974"},"reference-count":43,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"2","content-domain":{"domain":["lww.com","ovid.com"],"crossmark-restriction":true},"short-container-title":[],"published-print":{"date-parts":[[2016,4]]},"abstract":"<jats:p>The advances in thoracic procedures require optimum lung separation to provide adequate room for surgical access. This can be achieved using either a double-lumen tube (DLT) or a bronchial blocker (BB). Most thoracic anesthesiologists prefer the use of DLT. However, lung separation in patients with potential difficult airway can be achieved using either BB through a single lumen tube or placement of a DLT over a tube exchanger or a fiberoptic bronchoscope. Numerous videolaryngoscopes (VL) have been introduced offering both optical and video options to visualize the glottis. Many studies reported improved glottis visualization and easier DLT intubation in patients with normal and potential difficult airway. However, these studies have a wide diversity of outcomes, which may be attributed to the differences in their designs and the prior experience of the operators in using the different devices. In the present review, we present the main outcomes of the available publications, which have addressed the use of VL-guided DLT intubation. Currently, there is enough evidence supporting using VL for DLT intubation in patients with predicted and unanticipated difficult airway. In conclusion, the use of VL could offer an effective method of DLT placement for lung separation in patients with the potential difficult airway.<\/jats:p>","DOI":"10.4103\/1658-354x.168804","type":"journal-article","created":{"date-parts":[[2015,11,2]],"date-time":"2015-11-02T06:06:32Z","timestamp":1446444392000},"page":"218-227","update-policy":"https:\/\/doi.org\/10.1097\/lww.0000000000001000","source":"Crossref","is-referenced-by-count":20,"title":["Videolaryngoscopes for placement of double lumen tubes: Is it time to say goodbye to direct view?"],"prefix":"10.4103","volume":"10","author":[{"given":"MR","family":"El-Tahan","sequence":"first","affiliation":[{"name":"Department of Anesthesiology, University of Dammam, Dammam, Al Khubar 31952, Saudi Arabia"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"276","reference":[{"key":"R1-20250926","doi-asserted-by":"crossref","first-page":"1321","DOI":"10.1053\/j.jvca.2013.03.026","article-title":"Survey of thoracic anesthetic practice in Italy","volume":"27","author":"Della Rocca","year":"2013","journal-title":"J Cardiothorac Vasc Anesth"},{"key":"R2-20250926","doi-asserted-by":"crossref","first-page":"192","DOI":"10.4103\/1658-354X.101196","article-title":"Anesthesia for thoracic surgery: A survey of middle eastern practice","volume":"6","author":"Eldawlatly","year":"2012","journal-title":"Saudi J Anesth"},{"key":"R3-20250926","doi-asserted-by":"crossref","first-page":"1014","DOI":"10.1053\/j.jvca.2011.06.018","article-title":"Anesthesia for thoracic surgery: A survey of UK practice","volume":"25","author":"Shelley","year":"2011","journal-title":"J Cardiothorac Vasc Anesth"},{"key":"R4-20250926","doi-asserted-by":"crossref","first-page":"251","DOI":"10.1097\/ALN.0b013e31827773b2","article-title":"Practice guidelines for management of the difficult airway: An updated report by the American Society of Anesthesiologists Task Force on Management of the Difficult Airway","volume":"118","author":"Apfelbaum","year":"2013","journal-title":"Anesthesiology"},{"key":"R5-20250926","doi-asserted-by":"crossref","first-page":"1253","DOI":"10.1111\/anae.12322","article-title":"A randomised controlled trial comparing the GlideScope(\u00ae) and the Macintosh laryngoscope for double-lumen endobronchial intubation","volume":"68","author":"Russell","year":"2013","journal-title":"Anesthesia"},{"key":"R6-20250926","doi-asserted-by":"crossref","first-page":"376","DOI":"10.4103\/1658-354X.87266","article-title":"Use of Airtraq, C-Mac, and Glidescope laryngoscope is better than Macintosh in novice medical students\u2019 hands: A manikin study","volume":"5","author":"Kaki","year":"2011","journal-title":"Saudi J Anesth"},{"key":"R7-20250926","doi-asserted-by":"crossref","first-page":"170","DOI":"10.1053\/j.jvca.2007.04.006","article-title":"GlideScope-assisted double-lumen endobronchial tube placement in a patient with an unanticipated difficult airway","volume":"22","author":"Chen","year":"2008","journal-title":"J Cardiothorac Vasc Anesth"},{"key":"R8-20250926","doi-asserted-by":"crossref","first-page":"12","DOI":"10.1097\/ACO.0b013e328331e8a7","article-title":"Lung isolation techniques for patients with difficult airway","volume":"23","author":"Campos","year":"2010","journal-title":"Curr Opin Anesthesiol"},{"key":"R9-20250926","doi-asserted-by":"crossref","first-page":"72","DOI":"10.1186\/1471-2253-14-72","article-title":"A modified technique to improve the outcome of intubation with a left-sided double-lumen endobronchial tube","volume":"14","author":"Hsu","year":"2014","journal-title":"BMC Anesthesiol"},{"key":"R10-20250926","doi-asserted-by":"crossref","first-page":"449","DOI":"10.1213\/ANE.0000000000000250","article-title":"A simulator study of tube exchange with three different designs of double-lumen tubes","volume":"119","author":"Gamez","year":"2014","journal-title":"Anesth Analg"},{"key":"R11-20250926","doi-asserted-by":"crossref","first-page":"411","DOI":"10.1111\/j.1365-2044.2011.07049.x","article-title":"Comparison of the GlideScope\u00ae videolaryngoscope and the Macintosh laryngoscope for double-lumen tube intubation","volume":"67","author":"Hsu","year":"2012","journal-title":"Anesthesia"},{"key":"R12-20250926","doi-asserted-by":"crossref","first-page":"191","DOI":"10.1007\/BF03027728","article-title":"Early clinical experience with a new videolaryngoscope (GlideScope) in 728 patients","volume":"52","author":"Cooper","year":"2005","journal-title":"Can J Anesth"},{"key":"R13-20250926","doi-asserted-by":"crossref","first-page":"658","DOI":"10.1007\/BF03015787","article-title":"Using a Glidescope for intubation with a double lumen endotracheal tube","volume":"52","author":"Hernandez","year":"2005","journal-title":"Can J Anesth"},{"key":"R14-20250926","doi-asserted-by":"crossref","first-page":"346","DOI":"10.1016\/j.redar.2013.05.010","article-title":"Use of GlideScope for double lumen endotracheal tube insertion in an awake patient with difficult airway","volume":"61","author":"Onrubia","year":"2014","journal-title":"Rev Esp Anestesiol Reanim"},{"key":"R15-20250926","doi-asserted-by":"crossref","first-page":"282","DOI":"10.1007\/s12630-009-9243-2","article-title":"Sequential rotation to insert a left double-lumen endotracheal tube using the GlideScope","volume":"57","author":"Bustamante","year":"2010","journal-title":"Can J Anesth"},{"key":"R16-20250926","doi-asserted-by":"crossref","DOI":"10.1111\/anae.13040","article-title":"A comparison of the McGrath \u00ae Series 5 videolaryngoscope and Macintosh laryngoscope for double-lumen tracheal tube placement in patients with a good glottic view at direct laryngoscopy","author":"Yao","year":"2015","journal-title":"Anaesthesia"},{"key":"R17-20250926","doi-asserted-by":"crossref","first-page":"646","DOI":"10.1111\/anae.12720","article-title":"McGrath(\u00ae) series 5 videolaryngoscope evaluation for double-lumen tube intubation","volume":"69","author":"Yao","year":"2014","journal-title":"Anesthesia"},{"key":"R18-20250926","doi-asserted-by":"crossref","first-page":"845","DOI":"10.1053\/j.jvca.2012.01.014","article-title":"Video laryngoscopy versus direct laryngoscopy for double-lumen endotracheal tube intubation: A retrospective analysis","volume":"26","author":"Purugganan","year":"2012","journal-title":"J Cardiothorac Vasc Anesth"},{"key":"R19-20250926","doi-asserted-by":"crossref","first-page":"574","DOI":"10.4103\/1658-354X.140919","article-title":"Combination of Parker Flex-IT\u2122 Stylet and McGRATH MAC for effective double lumen tube intubation","volume":"8","author":"Ueshima","year":"2014","journal-title":"Saudi J Anesth"},{"key":"R20-20250926","doi-asserted-by":"crossref","first-page":"362","DOI":"10.1016\/j.jclinane.2015.03.012","article-title":"Efficacy of bronchofiberscope double-lumen tracheal tube intubation combined with McGRATH MAC for difficult airway","volume":"27","author":"Imajo","year":"2015","journal-title":"J Clin Anesth"},{"key":"R21-20250926","doi-asserted-by":"crossref","first-page":"1232","DOI":"10.1111\/j.1365-2044.2012.07261.x","article-title":"Evaluation of the CEL-100 videolaryngoscope(TM) for double-lumen tracheal tube insertion after failure using the Macintosh laryngoscope","volume":"67","author":"Lin","year":"2012","journal-title":"Anesthesia"},{"key":"R22-20250926","doi-asserted-by":"crossref","first-page":"771","DOI":"10.1111\/j.1365-2044.2012.07137.x","article-title":"A randomised trial comparing the CEL-100 videolaryngoscope(TM) with the Macintosh laryngoscope blade for insertion of double-lumen tubes","volume":"67","author":"Lin","year":"2012","journal-title":"Anesthesia"},{"key":"R23-20250926","doi-asserted-by":"crossref","first-page":"446","DOI":"10.1093\/bja\/aep164","article-title":"Tracheal intubation with videolaryngoscopes in patients with cervical spine immobilization: A randomized trial of the Airway Scope and the GlideScope","volume":"103","author":"Liu","year":"2009","journal-title":"Br J Anesth"},{"key":"R24-20250926","doi-asserted-by":"crossref","first-page":"180","DOI":"10.1097\/EJA.0b013e32835fe574","article-title":"Comparison of the Airtraq and the Macintosh laryngoscope for double-lumen tube intubation: A randomised clinical trial","volume":"30","author":"Wasem","year":"2013","journal-title":"Eur J Anesthesiol"},{"key":"R25-20250926","doi-asserted-by":"crossref","first-page":"955","DOI":"10.1007\/BF03026807","article-title":"The Airtraq laryngoscope for placement of double-lumen endobronchial tube","volume":"54","author":"Hirabayashi","year":"2007","journal-title":"Can J Anesth"},{"key":"R26-20250926","first-page":"89","article-title":"Usefulness of the Airtraq DL\u2122 videolaryngoscope for placing a double-lumen tube","volume":"34","author":"Chastel","year":"2015","journal-title":"Anesth Crit Care Pain Med"},{"key":"R27-20250926","first-page":"54","article-title":"Haemodynamic response at double lumen bronchial tube placement \u2014 Airtraq vs. MacIntosh laryngoscope, a randomised controlled trial","volume":"7","author":"Hamp","year":"2015","journal-title":"Heart Lung Vessel"},{"key":"R28-20250926","doi-asserted-by":"crossref","first-page":"58","DOI":"10.1186\/s12871-015-0037-5","article-title":"Comparison of the Airtraq laryngoscope and the GlideScope for double-lumen tube intubation in patients with predicted normal airways: A prospective randomized trial","volume":"15","author":"Yi","year":"2015","journal-title":"BMC Anesthesiol"},{"key":"R29-20250926","doi-asserted-by":"crossref","first-page":"315","DOI":"10.1016\/S0034-9356(11)70068-8","article-title":"Double lumen tube insertion in awake patients through the AirTraq laryngoscope in 2 cases of expected difficult airway","volume":"58","author":"Salazar Herbozo","year":"2011","journal-title":"Rev Esp Anestesiol Reanim"},{"key":"R30-20250926","first-page":"406","article-title":"Successful double-lumen tube insertion using Pentax-AWS Airwayscope with an infant-sized intlock in a rheumatoid arthritis patient with restricted mouth opening and head tilting","volume":"63","author":"Ono","year":"2014","journal-title":"Masui"},{"key":"R31-20250926","first-page":"817","article-title":"Usability of modified INTLOCK for double-lumen endobronchial tube insertion with airway scope","volume":"56","author":"Nakamura","year":"2007","journal-title":"Masui"},{"key":"R32-20250926","doi-asserted-by":"crossref","first-page":"926","DOI":"10.1053\/j.jvca.2008.12.015","article-title":"The airway scope is a practical intubation device for a double-lumen tube during rapid-sequence induction","volume":"23","author":"Yamazaki","year":"2009","journal-title":"J Cardiothorac Vasc Anesth"},{"key":"R33-20250926","doi-asserted-by":"crossref","first-page":"319","DOI":"10.1016\/j.jclinane.2008.02.003","article-title":"The Airway Scope for difficult double-lumen tube intubation","volume":"20","author":"Poon","year":"2008","journal-title":"J Clin Anesth"},{"key":"R34-20250926","doi-asserted-by":"crossref","first-page":"853","DOI":"10.1007\/BF03021719","article-title":"Double lumen tube placement with the Pentax-Airway Scope","volume":"54","author":"Suzuki","year":"2007","journal-title":"Can J Anesth"},{"key":"R35-20250926","doi-asserted-by":"crossref","first-page":"129","DOI":"10.12688\/f1000research.4481.3","article-title":"Case report: Double lumen tube insertion in a morbidly obese patient through the non-channelled blade of the King Vision (\u2122) videolaryngoscope","volume":"3","author":"El-Tahan","year":"2014","journal-title":"F1000Res"},{"key":"R36-20250926","doi-asserted-by":"crossref","first-page":"990","DOI":"10.1093\/bja\/aet281","article-title":"Double-lumen tube tracheal intubation using a rigid video-stylet: A randomized controlled comparison with the Macintosh laryngoscope","volume":"111","author":"Yang","year":"2013","journal-title":"Br J Anesth"},{"key":"R37-20250926","doi-asserted-by":"crossref","first-page":"85","DOI":"10.4097\/kjae.2013.65.1.85","article-title":"The use of the Clarus Video System for double-lumen endobronchial tube intubation in a patient with a difficult airway","volume":"65","author":"Kim","year":"2013","journal-title":"Korean J Anesthesiol"},{"key":"R38-20250926","doi-asserted-by":"crossref","first-page":"157","DOI":"10.4097\/kjae.2014.66.2.157","article-title":"An awake double lumen endotracheal tube intubation using the Clarus Video System in a patient with an epiglottic cyst: A case report","volume":"66","author":"Seo","year":"2014","journal-title":"Korean J Anesthesiol"},{"key":"R39-20250926","doi-asserted-by":"crossref","first-page":"851","DOI":"10.1111\/anae.12340","article-title":"Left endobronchial intubation with a double-lumen tube using direct laryngoscopy or the Trachway\u00ae video stylet","volume":"68","author":"Hsu","year":"2013","journal-title":"Anesthesia"},{"key":"R40-20250926","doi-asserted-by":"crossref","first-page":"774","DOI":"10.1053\/j.jvca.2006.07.023","article-title":"Positioning of double-lumen tubes by a lighted stylet","volume":"21","author":"Weng","year":"2007","journal-title":"J Cardiothorac Vasc Anesth"},{"key":"R41-20250926","doi-asserted-by":"crossref","first-page":"568","DOI":"10.4103\/0970-9185.142867","article-title":"Bonfils assisted double lumen endobronchial tube placement in an anticipated difficult airway","volume":"30","author":"Subramani","year":"2014","journal-title":"J Anesthesiol Clin Pharmacol"},{"key":"R42-20250926","doi-asserted-by":"crossref","first-page":"789","DOI":"10.1007\/s11739-014-1122-3","article-title":"Improvement in GlideScope\u00ae Video Laryngoscopy performance over a seven-year period in an academic emergency department","volume":"9","author":"Sakles","year":"2014","journal-title":"Intern Emerg Med"},{"key":"R43-20250926","doi-asserted-by":"crossref","first-page":"877","DOI":"10.1053\/j.jvca.2013.07.015","article-title":"High-fidelity simulation of lung isolation with double-lumen endotracheal tubes and bronchial blockers in anesthesiology resident training","volume":"28","author":"Failor","year":"2014","journal-title":"J Cardiothorac Vasc Anesth"}],"container-title":["Saudi Journal of Anaesthesia"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.ovid.com\/01437113-201610020-00020","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,8,18]],"date-time":"2026-08-18T15:45:53Z","timestamp":1787067953000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.ovid.com\/01437113-201610020-00020"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2016,4]]},"references-count":43,"journal-issue":{"issue":"2","published-print":{"date-parts":[[2016]]}},"URL":"https:\/\/doi.org\/10.4103\/1658-354x.168804","relation":{},"ISSN":["1658-354X","0975-3125"],"issn-type":[{"value":"1658-354X","type":"print"},{"value":"0975-3125","type":"electronic"}],"subject":[],"published":{"date-parts":[[2016,4]]}}}