{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,8,18]],"date-time":"2026-08-18T05:29:12Z","timestamp":1787030952399,"version":"build-2736575974"},"reference-count":20,"publisher":"Scientific Scholar","content-domain":{"domain":["clinicalimagingscience.org"],"crossmark-restriction":true},"short-container-title":[],"abstract":"<jats:sec id=\"st1\">\n                    <jats:title>Objective:<\/jats:title>\n                    <jats:p>The purpose of this study is to identify early computed tomography findings around the driveline which would predict mediastinal or left ventricular assist device (LVAD) pocket abscess formation.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec id=\"st2\">\n                    <jats:title>Materials and Methods:<\/jats:title>\n                    <jats:p>A retrospective analysis was performed on 128 LVAD recipients between January 2007 and December 2011. Infectious complications were subdivided into those affecting the driveline and those resulting in abscess formation either around the LVAD pump or mediastinum. The size and location of infiltrative changes surrounding the driveline were used to predict infection propagation resulting in abscess.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec id=\"st3\">\n                    <jats:title>Results:<\/jats:title>\n                    <jats:p>\n                      Of the 128 patients, 49 (38.3%) patients developed driveline infections and 24 (18.8%) patients developed abscess. 87.5% patients who developed abscess had a preceding driveline infection. The mean time from driveline infection to the development of pump pocket abscess was approximately 7 months. In addition, patients with abscess in the pump pocket or mediastinum had preceding infiltrative changes surrounding the driveline \u226514 mm (\n                      <jats:italic>P<\/jats:italic>\n                      = 0.0001). A preperitoneal location and size of infiltrative changes \u226514 mm were correlated with a higher likelihood of abscess formation (\n                      <jats:italic>P<\/jats:italic>\n                      = 0.0002).\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec id=\"st4\">\n                    <jats:title>Conclusion:<\/jats:title>\n                    <jats:p>Our study demonstrates the predictive value of infection\/infiltrative changes around the driveline, which increases the risk for abscess formation in the LVAD pump pocket and\/or in the mediastinum.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.4103\/2156-7514.192835","type":"journal-article","created":{"date-parts":[[2016,10,21]],"date-time":"2016-10-21T06:13:35Z","timestamp":1477030415000},"page":"43","update-policy":"https:\/\/doi.org\/10.25259\/crossmark_policy","source":"Crossref","is-referenced-by-count":10,"title":["The Role of Computed Tomography in Predicting Left Ventricular Assist Device Infectious Complications"],"prefix":"10.25259","volume":"6","author":[{"given":"Carrie K","family":"Gomez","sequence":"first","affiliation":[{"name":"Department of Imaging Sciences, University of Rochester, Rochester, New York, USA"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Scott R","family":"Schiffman","sequence":"additional","affiliation":[{"name":"Department of Imaging Sciences, University of Rochester, Rochester, New York, USA"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Susan K","family":"Hobbs","sequence":"additional","affiliation":[{"name":"Department of Imaging Sciences, University of Rochester, Rochester, New York, USA"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"10894","published-online":{"date-parts":[[2016,10,21]]},"reference":[{"key":"10.4103\/2156-7514.192835\/ref-1","first-page":"e6","article-title":"Heart disease and stroke statistics-2013 update: A report from the American Heart Association","volume":"127","author":"Go","year":"2013","journal-title":"Circulation"},{"key":"10.4103\/2156-7514.192835\/ref-2","doi-asserted-by":"crossref","first-page":"1381","DOI":"10.1016\/j.athoracsur.2012.05.074","article-title":"Driveline infections in left ventricular assist devices: Implications for destination therapy","volume":"94","author":"Sharma","year":"2012","journal-title":"Ann Thorac Surg"},{"key":"10.4103\/2156-7514.192835\/ref-3","doi-asserted-by":"crossref","first-page":"1807","DOI":"10.3390\/ijerph7041807","article-title":"The heart failure epidemic","volume":"7","author":"Roger","year":"2010","journal-title":"Int J Environ Res Public Health"},{"key":"10.4103\/2156-7514.192835\/ref-4","doi-asserted-by":"crossref","first-page":"1435","DOI":"10.1056\/NEJMoa012175","article-title":"Long-term use of a left ventricular assist device for end-stage heart failure","volume":"345","author":"Rose","year":"2001","journal-title":"N Engl J Med"},{"key":"10.4103\/2156-7514.192835\/ref-5","doi-asserted-by":"crossref","first-page":"429","DOI":"10.1148\/rg.302095734","article-title":"CT of left ventricular assist devices","volume":"30","author":"Carr","year":"2010","journal-title":"Radiographics"},{"key":"10.4103\/2156-7514.192835\/ref-6","doi-asserted-by":"crossref","first-page":"1081","DOI":"10.1016\/j.healun.2010.04.024","article-title":"Clinical management of continuous-flow left ventricular assist devices in advanced heart failure","volume":"29","author":"Swetz","year":"2010","journal-title":"J Heart Lung Transplant"},{"issue":"3 Suppl","key":"10.4103\/2156-7514.192835\/ref-7","doi-asserted-by":"crossref","first-page":"S116","DOI":"10.1016\/S0003-4975(00)02639-4","article-title":"HeartMate II left ventricular assist system: From concept to first clinical use","volume":"71","author":"Griffith","year":"2001","journal-title":"Ann Thorac Surg"},{"key":"10.4103\/2156-7514.192835\/ref-8","first-page":"582","article-title":"Hemorrhage and thrombosis with different LVAD technologies: A matter of flow?","volume":"3","author":"Tarzia","year":"2014","journal-title":"Ann Cardiothorac Surg"},{"key":"10.4103\/2156-7514.192835\/ref-9","first-page":"557","article-title":"Technique for minimizing and treating driveline infections","volume":"3","author":"Yarboro","year":"2014","journal-title":"Ann Cardiothorac Surg"},{"key":"10.4103\/2156-7514.192835\/ref-10","doi-asserted-by":"crossref","first-page":"201","DOI":"10.1586\/eri.12.163","article-title":"Current concepts in the diagnosis and management of left ventricular assist device infections","volume":"11","author":"Nienaber","year":"2013","journal-title":"Expert Rev Anti Infect Ther"},{"key":"10.4103\/2156-7514.192835\/ref-11","doi-asserted-by":"crossref","first-page":"515","DOI":"10.1016\/j.ccl.2011.08.004","article-title":"Left ventricular assist device driveline infections","volume":"29","author":"Pereda","year":"2011","journal-title":"Cardiol Clin"},{"key":"10.4103\/2156-7514.192835\/ref-12","doi-asserted-by":"crossref","first-page":"885","DOI":"10.1056\/NEJMoa067758","article-title":"Use of a continuous-flow device in patients awaiting heart transplantation","volume":"357","author":"Miller","year":"2007","journal-title":"N Engl J Med"},{"key":"10.4103\/2156-7514.192835\/ref-13","doi-asserted-by":"crossref","first-page":"1359","DOI":"10.1016\/j.healun.2003.09.025","article-title":"Infection in permanent circulatory support: Experience from the REMATCH trial","volume":"23","author":"Holman","year":"2004","journal-title":"J Heart Lung Transplant"},{"key":"10.4103\/2156-7514.192835\/ref-14","doi-asserted-by":"crossref","first-page":"396","DOI":"10.1016\/0003-4975(95)01020-3","article-title":"Results of extended bridge to transplantation: Window into the future of permanent ventricular assist devices","volume":"61","author":"Griffith","year":"1996","journal-title":"Ann Thorac Surg"},{"key":"10.4103\/2156-7514.192835\/ref-15","doi-asserted-by":"crossref","first-page":"1632","DOI":"10.1016\/j.jtcvs.2010.01.014","article-title":"Infection after implantation of pulsatile mechanical circulatory support devices","volume":"139","author":"Holman","year":"2010","journal-title":"J Thorac Cardiovasc Surg"},{"key":"10.4103\/2156-7514.192835\/ref-16","doi-asserted-by":"crossref","first-page":"164","DOI":"10.1016\/j.healun.2010.08.003","article-title":"Infectious complications after pulsatile-flow and continuous-flow left ventricular assist device implantation","volume":"30","author":"Schaffer","year":"2011","journal-title":"J Heart Lung Transplant"},{"key":"10.4103\/2156-7514.192835\/ref-17","doi-asserted-by":"crossref","first-page":"237","DOI":"10.1016\/j.healun.2008.12.007","article-title":"Effect of left ventricular assist device infection on post-transplant outcomes","volume":"28","author":"Schulman","year":"2009","journal-title":"J Heart Lung Transplant"},{"key":"10.4103\/2156-7514.192835\/ref-18","doi-asserted-by":"crossref","first-page":"2241","DOI":"10.1056\/NEJMoa0909938","article-title":"Advanced heart failure treated with continuous-flow left ventricular assist device","volume":"361","author":"Slaughter","year":"2009","journal-title":"N Engl J Med"},{"key":"10.4103\/2156-7514.192835\/ref-19","doi-asserted-by":"crossref","first-page":"1270","DOI":"10.1016\/j.athoracsur.2010.04.093","article-title":"Infectious complications in patients with left ventricular assist device: Etiology and outcomes in the continuous-flow era","volume":"90","author":"Topkara","year":"2010","journal-title":"Ann Thorac Surg"},{"key":"10.4103\/2156-7514.192835\/ref-20","doi-asserted-by":"crossref","first-page":"627","DOI":"10.1586\/erd.11.36","article-title":"Left ventricular assist device-related infections: Past, present and future","volume":"8","author":"Maniar","year":"2011","journal-title":"Expert Rev Med Devices"}],"container-title":["Journal of Clinical Imaging Science"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/clinicalimagingscience.org\/the-role-of-computed-tomography-in-predicting-left-ventricular-assist-device-infectious-complications\/","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/clinicalimagingscience.org\/the-role-of-computed-tomography-in-predicting-left-ventricular-assist-device-infectious-complications\/","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2019,8,30]],"date-time":"2019-08-30T01:29:39Z","timestamp":1567128579000},"score":1,"resource":{"primary":{"URL":"https:\/\/clinicalimagingscience.org\/the-role-of-computed-tomography-in-predicting-left-ventricular-assist-device-infectious-complications\/"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2016,10,21]]},"references-count":20,"alternative-id":["10.4103\/2156-7514.192835"],"URL":"https:\/\/doi.org\/10.4103\/2156-7514.192835","relation":{},"ISSN":["2156-7514"],"issn-type":[{"value":"2156-7514","type":"electronic"}],"subject":[],"published":{"date-parts":[[2016,10,21]]},"article-number":"43"}}