{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,8,26]],"date-time":"2026-08-26T16:20:02Z","timestamp":1787761202622,"version":"build-2784847793"},"reference-count":19,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"3","content-domain":{"domain":["lww.com","ovid.com"],"crossmark-restriction":true},"short-container-title":[],"published-print":{"date-parts":[[2023,7]]},"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:sec>\n                    <jats:title>PURPOSE:<\/jats:title>\n                    <jats:p>The purpose of this study was to evaluate the safety and efficacy of one trabecular microbypass stent (first generation iStent) combined with phacoemulsification cataract surgery (phaco) in eyes with open-angle glaucoma (OAG) in a Taiwanese population.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>MATERIALS AND METHODS:<\/jats:title>\n                    <jats:p>One trabecular microbypass stent was implanted after phacoemulsification cataract surgery by one surgeon. Intraocular pressure (IOP), medications, corrected distance visual acuity, complications, and adverse events were evaluated.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>RESULTS:<\/jats:title>\n                    <jats:p>\n                      This case series included 28 eyes of 25 patients with OAG (19 primary open-angle glaucoma [POAG] and 9 normal tension glaucoma [NTG]). None had previous trabeculectomy or laser trabeculoplasty. At 1 year, the mean IOP decreased from 19.34 \u00b1 3.92 mmHg to 15.84 \u00b1 3.05 mmHg, and the mean number of glaucoma medications decreased from 1.82 \u00b1 1.12 to 0.79 \u00b1 1.17 (both\n                      <jats:italic toggle=\"yes\">P<\/jats:italic>\n                      &lt; 0.001). Longer survival was observed in the NTG eyes (NTG: 11.67 \u00b1 1.00 months, POAG: 9.53 \u00b1 3.78 months,\n                      <jats:italic toggle=\"yes\">P<\/jats:italic>\n                      = 0.031). iStent reposition was performed in one eye, and four eyes received laser treatment for stent occlusion. None had secondary glaucoma surgery.\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>CONCLUSION:<\/jats:title>\n                    <jats:p>Combined phacoemulsification and iStent implantations are a safe and effective way in reducing IOP and medication burden in patients with OAG, especially NTG.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.4103\/2211-5056.364567","type":"journal-article","created":{"date-parts":[[2022,12,21]],"date-time":"2022-12-21T00:36:56Z","timestamp":1671583016000},"page":"360-365","update-policy":"https:\/\/doi.org\/10.1097\/lww.0000000000001000","source":"Crossref","is-referenced-by-count":1,"title":["Trabecular microbypass stent combined with phacoemulsification in patients with open-angle glaucoma, 1-year outcome in a Taiwanese population"],"prefix":"10.4103","volume":"13","author":[{"given":"Wei-Wen","family":"Su","sequence":"first","affiliation":[{"name":"Department of Ophthalmology, Chang Gung Memorial Hospital, Taoyuan, Taiwan"},{"name":"Chang Gung University College of Medicine, Taoyuan, Taiwan"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"276","published-online":{"date-parts":[[2022,12,21]]},"reference":[{"key":"R1-20240830","doi-asserted-by":"crossref","first-page":"262","DOI":"10.1136\/bjo.2005.081224","article-title":"The number of people with glaucoma worldwide in 2010 and 2020","volume":"90","author":"Quigley","year":"2006","journal-title":"Br J Ophthalmol"},{"key":"R2-20240830","doi-asserted-by":"crossref","first-page":"e0162229","DOI":"10.1371\/journal.pone.0162229","article-title":"Number of people blind or visually impaired by glaucoma worldwide and in world regions 1990 \u20132010:A meta-analysis","volume":"11","author":"Bourne","year":"2016","journal-title":"PLoS One"},{"key":"R3-20240830","doi-asserted-by":"crossref","first-page":"e888","DOI":"10.1016\/S2214-109X(17)30293-0","article-title":"Magnitude, temporal trends, and projections of the global prevalence of blindness and distance and near vision impairment:A systematic review and meta-analysis","volume":"5","author":"Bourne","year":"2017","journal-title":"Lancet Glob Health"},{"key":"R4-20240830","doi-asserted-by":"crossref","first-page":"804","DOI":"10.1016\/j.ajo.2011.10.024","article-title":"Postoperative complications in the Tube Versus Trabeculectomy (TVT) study during five years of follow-up","volume":"153","author":"Gedde","year":"2012","journal-title":"Am J Ophthalmol"},{"key":"R5-20240830","doi-asserted-by":"crossref","first-page":"96","DOI":"10.1097\/ICU.0b013e32834ff1e7","article-title":"Micro-invasive glaucoma surgery:Current perspectives and future directions","volume":"23","author":"Saheb","year":"2012","journal-title":"Curr Opin Ophthalmol"},{"key":"R6-20240830","doi-asserted-by":"crossref","first-page":"135","DOI":"10.1007\/s40123-016-0054-6","article-title":"The new era of glaucoma micro-stent surgery","volume":"5","author":"Manasses","year":"2016","journal-title":"Ophthalmol Ther"},{"key":"R7-20240830","doi-asserted-by":"crossref","first-page":"1339","DOI":"10.1016\/j.jcrs.2012.03.025","article-title":"Cataract surgery with trabecular micro-bypass stent implantation in patients with mild-to-moderate open-angle glaucoma and cataract:Two-year follow-up","volume":"38","author":"Craven","year":"2012","journal-title":"J Cataract Refract Surg"},{"key":"R8-20240830","doi-asserted-by":"crossref","first-page":"1332","DOI":"10.1016\/j.jcrs.2016.07.023","article-title":"Outcomes after combined phacoemulsification and trabecular microbypass stent implantation in controlled open-angle glaucoma","volume":"42","author":"Seibold","year":"2016","journal-title":"J Cataract Refract Surg"},{"key":"R9-20240830","doi-asserted-by":"crossref","first-page":"407","DOI":"10.1016\/j.jcrs.2009.10.031","article-title":"Phacoemulsification versus phacoemulsification with micro-bypass stent implantation in primary open-angle glaucoma:Randomized double-masked clinical trial","volume":"36","author":"Fea","year":"2010","journal-title":"J Cataract Refract Surg"},{"key":"R10-20240830","doi-asserted-by":"crossref","first-page":"459","DOI":"10.1016\/j.ophtha.2010.07.007","article-title":"Randomized evaluation of the trabecular micro-bypass stent with phacoemulsification in patients with glaucoma and cataract","volume":"118","author":"Samuelson","year":"2011","journal-title":"Ophthalmology"},{"key":"R11-20240830","doi-asserted-by":"crossref","first-page":"1250","DOI":"10.1136\/bjophthalmol-2012-302394","article-title":"Mid-term evaluation of the new Glaukos iStent with phacoemulsification in coexistent open-angle glaucoma or ocular hypertension and cataract","volume":"97","author":"Arriola-Villalobos","year":"2013","journal-title":"Br J Ophthalmol"},{"key":"R12-20240830","doi-asserted-by":"crossref","first-page":"648","DOI":"10.1111\/ceo.12098","article-title":"Manchester iStent study:Early results from a prospective UK case series","volume":"41","author":"Patel","year":"2013","journal-title":"Clin Exp Ophthalmol"},{"key":"R13-20240830","doi-asserted-by":"crossref","first-page":"3327","DOI":"10.1167\/iovs.09-3972","article-title":"Fluorophotometric study of the effect of the glaukos trabecular microbypass stent on aqueous humor dynamics","volume":"51","author":"Fern\u00e1ndez-Barrientos","year":"2010","journal-title":"Invest Ophthalmol Vis Sci"},{"key":"R14-20240830","doi-asserted-by":"crossref","first-page":"1295","DOI":"10.1016\/j.jcrs.2014.07.004","article-title":"Prospective evaluation of microinvasive glaucoma surgery with trabecular microbypass stents and prostaglandin in open-angle glaucoma","volume":"40","author":"Ahmed","year":"2014","journal-title":"J Cataract Refract Surg"},{"key":"R15-20240830","first-page":"2313","article-title":"Prospective, randomized study of one, two, or three trabecular bypass stents in open-angle glaucoma subjects on topical hypotensive medication","volume":"9","author":"Katz","year":"2015","journal-title":"Clin Ophthalmol"},{"key":"R16-20240830","doi-asserted-by":"crossref","first-page":"1767","DOI":"10.2147\/OPTH.S114306","article-title":"Clinical evaluation of a trabecular microbypass stent with phacoemulsification in patients with open-angle glaucoma and cataract","volume":"10","author":"Ferguson","year":"2016","journal-title":"Clin Ophthalmol"},{"key":"R17-20240830","doi-asserted-by":"crossref","first-page":"976","DOI":"10.1007\/s12325-019-00899-5","article-title":"Case Series of combined iStent implantation and phacoemulsification in eyes with primary angle closure disease:One-year outcomes","volume":"36","author":"Hernstadt","year":"2019","journal-title":"Adv Ther"},{"key":"R18-20240830","doi-asserted-by":"crossref","first-page":"1294","DOI":"10.1016\/j.ophtha.2015.03.021","article-title":"The effect of phacoemulsification on intraocular pressure in glaucoma patients:A report by the American academy of ophthalmology","volume":"122","author":"Chen","year":"2015","journal-title":"Ophthalmology"},{"key":"R19-20240830","doi-asserted-by":"crossref","first-page":"5346","DOI":"10.1167\/iovs.08-1707","article-title":"Reduction of the available area for aqueous humor outflow and increase in meshwork herniations into collector channels following acute IOP elevation in bovine eyes","volume":"49","author":"Battista","year":"2008","journal-title":"Invest Ophthalmol Vis Sci"}],"container-title":["Taiwan Journal of Ophthalmology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.ovid.com\/10.4103\/2211-5056.364567","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,8,26]],"date-time":"2026-08-26T15:26:15Z","timestamp":1787757975000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.ovid.com\/10.4103\/2211-5056.364567"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2022,12,21]]},"references-count":19,"journal-issue":{"issue":"3","published-print":{"date-parts":[[2023]]}},"URL":"https:\/\/doi.org\/10.4103\/2211-5056.364567","relation":{},"ISSN":["2211-5056","2211-5072"],"issn-type":[{"value":"2211-5056","type":"print"},{"value":"2211-5072","type":"electronic"}],"subject":[],"published":{"date-parts":[[2022,12,21]]},"assertion":[{"value":"2022-08-30","name":"received","label":"Received","group":{"name":"publication_history","label":"Publication History"}},{"value":"2022-10-31","name":"accepted","label":"Accepted","group":{"name":"publication_history","label":"Publication History"}}]}}