{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,8,18]],"date-time":"2026-08-18T16:44:55Z","timestamp":1787071495535,"version":"build-2736575974"},"reference-count":22,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"4","content-domain":{"domain":["lww.com","ovid.com"],"crossmark-restriction":true},"short-container-title":[],"published-print":{"date-parts":[[2014,7]]},"abstract":"<jats:sec>\n                    <jats:title>Background:<\/jats:title>\n                    <jats:p>The purpose of this study was to evaluate the value of Tc-99m pertechnetate planar, dual-phase MIBI and MIBI-SPECT images in the determination and localization of parathyroid lesions.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Materials and Methods:<\/jats:title>\n                    <jats:p>In this study, 38 patients who underwent operation for primary hyperparathyroidism were included. Tc-99m pertechnetate planar-pinhole imaging of the neck and then MIBI planar and SPECT images in supine position was performed. Late SPECT images were acquired 120 minutes after the injection. Early and late MIBI images were quantitatively evaluated.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results:<\/jats:title>\n                    <jats:p>Of the 38 patients, 30 of them had adenoma, 2 patients had hyperplasia and 6 of them were normal on planar images. Thirty-four of 38 patients were positive on SPECT images. SPECT images of the patients with positive results were matched with pathology results.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusion:<\/jats:title>\n                    <jats:p>As a result, Tc-99m pertechnetate planar-pinhole, Tc-99m MIBI planar and SPECT images are useful for localization of parathyroid lesions especially in multinodular thyroid gland. However, US or CT images are necessary for more accurate localization and Tc-99m pertechnetate images are useful for interpreting and comparing with the early and late MIBI images.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.4103\/2230-8210.137520","type":"journal-article","created":{"date-parts":[[2014,7,23]],"date-time":"2014-07-23T07:26:23Z","timestamp":1406100383000},"page":"531-536","update-policy":"https:\/\/doi.org\/10.1097\/lww.0000000000001000","source":"Crossref","is-referenced-by-count":1,"title":["Comparison of Tc-99m pertechnetate images with dual-phase Tc 99m MIBI and SPECT images in primary hyperparathyroidism"],"prefix":"10.4103","volume":"18","author":[{"given":"Sait","family":"Sager","sequence":"first","affiliation":[{"name":"Department of Nuclear Medicine, Istanbul University, Cerrahpasa Medical Faculty, Istanbul, Turkey"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Hojjat","family":"Shafipour","sequence":"additional","affiliation":[{"name":"Department of Nuclear Medicine, Istanbul University, Cerrahpasa Medical Faculty, Istanbul, Turkey"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Sertac","family":"Asa","sequence":"additional","affiliation":[{"name":"Department of Nuclear Medicine, Istanbul University, Cerrahpasa Medical Faculty, Istanbul, Turkey"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Sabire","family":"Y\u0131lmaz","sequence":"additional","affiliation":[{"name":"Department of Nuclear Medicine, Istanbul University, Cerrahpasa Medical Faculty, Istanbul, Turkey"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Serkan","family":"Teks\u00f6z","sequence":"additional","affiliation":[{"name":"Department of Endocrine Surgery, Istanbul University, Cerrahpasa Medical Faculty, Istanbul, Turkey"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"\u00c7etin","family":"\u00d6nsel","sequence":"additional","affiliation":[{"name":"Department of Nuclear Medicine, Istanbul University, Cerrahpasa Medical Faculty, Istanbul, Turkey"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"276","reference":[{"key":"R1-20260327","doi-asserted-by":"crossref","first-page":"39","DOI":"10.1111\/j.1365-2362.1988.tb01163.x","article-title":"Prevalence of hypercalcemia in a health survey: A 14-year follow-up study of serum calcium values","volume":"18","author":"Palmer","year":"1988","journal-title":"Eur J Clin Invest"},{"key":"R2-20260327","doi-asserted-by":"crossref","first-page":"116","DOI":"10.1159\/000323912","article-title":"Can ultrasound be used as the primary screening modality for the localization of parathyroid disease prior to surgery for primary hyperparathyroidism? A review of 440 cases","volume":"73","author":"Levy","year":"2011","journal-title":"ORL J Otorhinolaryngol Relat Spec"},{"key":"R3-20260327","doi-asserted-by":"crossref","first-page":"239","DOI":"10.1016\/S0009-9260(05)81656-3","article-title":"Pre-operative localisation in primary hyperparathyroidism","volume":"41","author":"Lloyd","year":"1990","journal-title":"Clin Radiol"},{"key":"R4-20260327","doi-asserted-by":"crossref","first-page":"967","DOI":"10.1016\/j.crad.2004.04.005","article-title":"Imaging for primary hyperparathyroidism- what beginners should know","volume":"59","author":"Ahuja","year":"2004","journal-title":"Clin Radiol"},{"key":"R5-20260327","doi-asserted-by":"crossref","first-page":"29","DOI":"10.1067\/msy.2000.107066","article-title":"Technetium 99m-MIBI-SPECT: A highly sensitive diagnostic tool for Localization of Parathyroid adenomas","volume":"128","author":"Moka","year":"2000","journal-title":"Surgery"},{"key":"R6-20260327","doi-asserted-by":"crossref","first-page":"949","DOI":"10.1097\/MNM.0b013e328309789e","article-title":"Comparison of pin hole and SPECT Tc-99m-MIBI imaging in primary hyperparathyroidism","volume":"29","author":"HoShon","year":"2008","journal-title":"Nucl Med Commun"},{"key":"R7-20260327","doi-asserted-by":"crossref","first-page":"39","DOI":"10.1097\/00006231-200101000-00006","article-title":"The relationship between 99Tc (m)-sestamibi uptake and ultrastructural cell types of thyroid tumours","volume":"22","author":"Sarikaya","year":"2001","journal-title":"Nucl Med Commun"},{"key":"R8-20260327","doi-asserted-by":"crossref","first-page":"998","DOI":"10.1016\/S0039-6060(99)70053-X","article-title":"The evolution of parathyroidectomy failures","volume":"126","author":"Boggs","year":"1999","journal-title":"Surgery"},{"key":"R9-20260327","first-page":"241","article-title":"Parathyroid scintigraphy: Rapid washout of technetium 99m MIBI from a large parathyroid adenoma","volume":"34","author":"Benard","year":"1995","journal-title":"J Nucl Med"},{"key":"R10-20260327","doi-asserted-by":"crossref","first-page":"651","DOI":"10.1097\/RLU.0b013e3181b591c9","article-title":"Single photonemission computed tomography (SPECT) should be routinely performed for thedetection of parathyroid abnormalities utilizing technetium-99m sestamibiparathyroid scintigraphy","volume":"34","author":"Thomas","year":"2009","journal-title":"Clin Nucl Med"},{"key":"R11-20260327","doi-asserted-by":"crossref","first-page":"736","DOI":"10.1007\/s002590100523","article-title":"The value of oblique pinhole images in pre-operative localization with Tc-99m-MIBI for primary hyperparathyroidism","volume":"28","author":"Ho Shon","year":"2001","journal-title":"Eur J Nucl Med"},{"key":"R12-20260327","doi-asserted-by":"crossref","first-page":"221","DOI":"10.1148\/radiol.2481071066","article-title":"Preoperative parathyroid scintigraphic lesion localization: Accuracy of various types of readings","volume":"248","author":"Nichols","year":"2008","journal-title":"Radiology"},{"key":"R13-20260327","first-page":"40","article-title":"The usefulness of neck pinhole SPECT as a complementary tool to planar scintigraphy in primary and secondary hyperparathyroidism","volume":"45","author":"Spanu","year":"2004","journal-title":"J Nucl Med"},{"key":"R14-20260327","doi-asserted-by":"crossref","first-page":"249","DOI":"10.1097\/00003072-200204000-00003","article-title":"Presurgical localization of abnormal parathyroid glands using a single injection of Tc-99m sestamibi: comparison of high-resolution parallel-hole and pinhole collimators, and interobserver and intraobserver","volume":"27","author":"Arveschoug","year":"2002","journal-title":"Clin Nucl Med"},{"key":"R15-20260327","doi-asserted-by":"crossref","first-page":"149","DOI":"10.1067\/msy.2002.119817","article-title":"Prospective evaluation of delayed technetium-99m sestamibi SPECT scintigraphy for preoperative localization of primarhy perparathyroidism","volume":"131","author":"Civelek","year":"2002","journal-title":"Surgery"},{"key":"R16-20260327","first-page":"85","article-title":"Parathyroid adenomas: Accurate detection and localization with Tc-99m sestamibiSpect","volume":"201","author":"Perez-Monte","year":"1996","journal-title":"Radiololgy"},{"key":"R17-20260327","doi-asserted-by":"crossref","first-page":"221","DOI":"10.1148\/radiol.2481071066","article-title":"Preoperative parathyroid scintigraphic lesion localization: Accuracyof various types of readings","volume":"248","author":"Nichols","year":"2008","journal-title":"Radiology"},{"key":"R18-20260327","doi-asserted-by":"crossref","first-page":"433","DOI":"10.1001\/archsurg.139.4.433","article-title":"Early, postinjection MIBI-SPECT as the only preoperative localizing study for minimally invasive parathyroidectomy","volume":"139","author":"Schachter","year":"2004","journal-title":"Arch Surg"},{"key":"R19-20260327","first-page":"834","article-title":"Comparison of parathyroid imaging with technetium-99m-pertechnetate\/sestamibi subtraction, double-phase technetium-99m-sestamibi and technetium-99m-sestamibi SPECT","volume":"38","author":"Chen","year":"1997","journal-title":"J Nucl Med"},{"key":"R20-20260327","doi-asserted-by":"crossref","first-page":"143","DOI":"10.1007\/BF02439546","article-title":"Comparison and histopathological correlation of three parathyroid imaging methods in a population with a high prevalence of concomitant thyroid diseases","volume":"24","author":"Staudenherz","year":"1997","journal-title":"Eur J Nucl Med"},{"key":"R21-20260327","doi-asserted-by":"crossref","first-page":"128","DOI":"10.1007\/s00268-010-0818-4","article-title":"Limitations of Tc99m-MIBI-SPECT imaging scans in persistent primary hyperparathyroidism","volume":"35","author":"Witteveen","year":"2010","journal-title":"World J Surg"},{"key":"R22-20260327","doi-asserted-by":"crossref","first-page":"1071","DOI":"10.1001\/archotol.134.10.1071","article-title":"Correlation of plasma 25-hydroxyvitamin D levels with severity of primary hyperparathyroidism and likelihood of parathyroid adenoma localization on sestamibi scan","volume":"134","author":"Kandil","year":"2008","journal-title":"Arch Otolaryngol Head Neck Surg"}],"container-title":["Indian Journal of Endocrinology and Metabolism"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.ovid.com\/02223308-201418040-00018","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,8,18]],"date-time":"2026-08-18T15:47:00Z","timestamp":1787068020000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.ovid.com\/02223308-201418040-00018"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2014,7]]},"references-count":22,"journal-issue":{"issue":"4","published-print":{"date-parts":[[2014]]}},"URL":"https:\/\/doi.org\/10.4103\/2230-8210.137520","relation":{},"ISSN":["2230-8210","2230-9500"],"issn-type":[{"value":"2230-8210","type":"print"},{"value":"2230-9500","type":"electronic"}],"subject":[],"published":{"date-parts":[[2014,7]]}}}