{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,8,26]],"date-time":"2026-08-26T20:26:38Z","timestamp":1787775998322,"version":"build-2784847793"},"reference-count":14,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"1","content-domain":{"domain":["lww.com","ovid.com"],"crossmark-restriction":true},"short-container-title":[],"published-print":{"date-parts":[[2017,1]]},"abstract":"<jats:sec>\n                    <jats:title>Background:<\/jats:title>\n                    <jats:p>To assess the clinical consequences of AcrySof toric intraocular lens (IOL) and Hoya toric IOL implantation to correct preexisting corneal astigmatism in patients undergoing cataract surgery.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Materials and Methods:<\/jats:title>\n                    <jats:p>In this study, we examined 55 eyes of 45 patients with at least 1.00 D corneal astigmatism who were scheduled for cataract surgery. After phacoemulsification, toric IOL was inserted and axis was aligned. We observed the patients, uncorrected distance visual acuity (UDVA), corrected distance visual acuity (CDVA), keratometry, manifest refraction, and IOL axis alignment 6 months after surgery.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results:<\/jats:title>\n                    <jats:p>\n                      After 6 months, the UDVA was 0.17 \u00b1 0.17 logMAR in the AcrySof group and 0.17 \u00b1 0.18 logMar in the Hoya group. More than 78% of eyes in the AcrySof group and 80% of eyes in the Hoya toric IOL achieved a UDVA of 20\/40 or better. In the AcrySof group, the mean preoperative corneal astigmatism was 2.73 \u00b1 0.92 D. The mean postoperative refractive astigmatism was 0.84 \u00b1 0.63 D. In the Hoya group, the preoperative corneal astigmatism was 2.58 \u00b1 0.76 D and the postoperative refractive astigmatism was 0.87 \u00b1 0.66 D (\n                      <jats:italic toggle=\"yes\">P<\/jats:italic>\n                      &lt; 0.05). The mean AcrySof IOL axis rotation was 1.88\u00b0 \u00b1 3.05\u00b0. In the Hoya group, the mean axis rotation was 1.53\u00b0 \u00b1 3.66\u00b0. All changes in visual and refractive data before and after surgery were statistically significant (\n                      <jats:italic toggle=\"yes\">P<\/jats:italic>\n                      &lt; 0.05). There was no significant difference between the two groups regarding refractive and visual outcome after surgery (\n                      <jats:italic toggle=\"yes\">P<\/jats:italic>\n                      &gt; 0.05 for all).\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusion:<\/jats:title>\n                    <jats:p>Implantation of AcrySof toric IOL and Hoya toric IOL was an effective way to correct preexisting corneal astigmatism in cataract surgery.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.4103\/2277-9175.216777","type":"journal-article","created":{"date-parts":[[2017,10,16]],"date-time":"2017-10-16T06:00:40Z","timestamp":1508133640000},"update-policy":"https:\/\/doi.org\/10.1097\/lww.0000000000001000","source":"Crossref","is-referenced-by-count":10,"title":["Toric Intraocular Lens for Astigmatism Correction in Cataract Patients"],"prefix":"10.4103","volume":"6","author":[{"given":"Hassan","family":"Razmjoo","sequence":"first","affiliation":[{"name":"From the Department of Ophthalmology, Feiz Hospital, Isfahan University of Medical Sciences, Isfahan, Iran"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Mohammad","family":"Ghoreishi","sequence":"additional","affiliation":[{"name":"From the Department of Ophthalmology, Feiz Hospital, Isfahan University of Medical Sciences, Isfahan, Iran"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Azadeh Mohammadi","family":"Milasi","sequence":"additional","affiliation":[{"name":"From the Department of Ophthalmology, Feiz Hospital, Isfahan University of Medical Sciences, Isfahan, Iran"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Alireza","family":"Peyman","sequence":"additional","affiliation":[{"name":"From the Department of Ophthalmology, Feiz Hospital, Isfahan University of Medical Sciences, Isfahan, Iran"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Zahra","family":"Jafarzadeh","sequence":"additional","affiliation":[{"name":"Department of Ophthalmology, Kashani Hospital, Shahrekord University of Medical Science, Isfahan, Iran"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Mohadeseh","family":"Mohammadinia","sequence":"additional","affiliation":[{"name":"From the Department of Ophthalmology, Feiz Hospital, Isfahan University of Medical Sciences, Isfahan, Iran"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Nasrollahi","family":"Kobra","sequence":"additional","affiliation":[{"name":"From the Department of Ophthalmology, Feiz Hospital, Isfahan University of Medical Sciences, Isfahan, Iran"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"276","published-online":{"date-parts":[[2017,10,16]]},"reference":[{"key":"R1-20250806","doi-asserted-by":"crossref","first-page":"41","DOI":"10.1186\/1471-2415-12-41","article-title":"Visual acuity improvements after implantation of toric intraocular lenses in cataract patients with astigmatism: A systematic review","volume":"12","author":"Agresta","year":"2012","journal-title":"BMC Ophthalmol"},{"key":"R2-20250806","doi-asserted-by":"crossref","first-page":"360","DOI":"10.1016\/S0002-9394(14)74917-7","article-title":"Biometry of 7,500 cataractous eyes","volume":"90","author":"Hoffer","year":"1980","journal-title":"Am J Ophthalmol"},{"key":"R3-20250806","doi-asserted-by":"crossref","first-page":"523","DOI":"10.1016\/S0886-3350(13)80232-5","article-title":"Toric intraocular lenses: Correcting astigmatism while controlling axis shift","volume":"20","author":"Shimizu","year":"1994","journal-title":"J Cataract Refract Surg"},{"key":"R4-20250806","doi-asserted-by":"crossref","first-page":"1479","DOI":"10.1016\/j.jcrs.2010.02.025","article-title":"Analysis of biometry and prevalence data for corneal astigmatism in 23,239 eyes","volume":"36","author":"Hoffmann","year":"2010","journal-title":"J Cataract Refract Surg"},{"key":"R6-20250806","doi-asserted-by":"crossref","first-page":"1700","DOI":"10.1016\/j.jcrs.2010.04.043","article-title":"Comparison of toric intraocular lenses and peripheral corneal relaxing incisions to treat astigmatism during cataract surgery","volume":"36","author":"Mingo-Bot\u00edn","year":"2010","journal-title":"J Cataract Refract Surg"},{"key":"R7-20250806","doi-asserted-by":"crossref","first-page":"601","DOI":"10.1016\/j.jcrs.2007.11.033","article-title":"Foldable toric intraocular lens for astigmatism correction in cataract patients","volume":"34","author":"Mendicute","year":"2008","journal-title":"J Cataract Refract Surg"},{"key":"R8-20250806","doi-asserted-by":"crossref","first-page":"1492","DOI":"10.1016\/j.jcrs.2006.04.022","article-title":"Evaluation of a toric intraocular lens with a Z-haptic","volume":"32","author":"De Silva","year":"2006","journal-title":"J Cataract Refract Surg"},{"key":"R9-20250806","doi-asserted-by":"crossref","first-page":"609","DOI":"10.1016\/j.jcrs.2009.10.044","article-title":"Canadian Toric Study Group. Visual function and patient experience after bilateral implantation of toric intraocular lenses","volume":"36","author":"Ahmed","year":"2010","journal-title":"J Cataract Refract Surg"},{"key":"R12-20250806","doi-asserted-by":"crossref","first-page":"31","DOI":"10.1016\/S0886-3350(00)00798-7","article-title":"Astigmatism analysis by the Alpins method","volume":"27","author":"Alpins","year":"2001","journal-title":"J Cataract Refract Surg"},{"key":"R13-20250806","doi-asserted-by":"crossref","first-page":"8","DOI":"10.1186\/1471-2415-8-8","article-title":"Rotational stability of the AcrySof SA60TT toric intraocular lenses: A cohort study","volume":"8","author":"Zuberbuhler","year":"2008","journal-title":"BMC Ophthalmol"},{"key":"R14-20250806","doi-asserted-by":"crossref","first-page":"1483","DOI":"10.1016\/j.jcrs.2008.05.031","article-title":"Astigmatism management in cataract surgery with the AcrySof toric intraocular lens","volume":"34","author":"Bauer","year":"2008","journal-title":"J Cataract Refract Surg"},{"key":"R15-20250806","doi-asserted-by":"crossref","first-page":"953","DOI":"10.1016\/S0886-3350(99)00085-1","article-title":"Comparison of the effects of viscoelastic agents on clinical properties of the Unfolder lens injection system","volume":"25","author":"Myers","year":"1999","journal-title":"J Cataract Refract Surg"},{"key":"R16-20250806","doi-asserted-by":"crossref","first-page":"376","DOI":"10.1038\/eye.2009.150","article-title":"Miyake-Apple study of the rotational stability of the Acrysof toric intraocular lens after experimental eye trauma","volume":"24","author":"Pereira","year":"2010","journal-title":"Eye (Lond)"},{"key":"R17-20250806","doi-asserted-by":"crossref","first-page":"1842","DOI":"10.1016\/j.jcrs.2008.07.012","article-title":"Comparative rotational stability of single-piece open-loop acrylic and plate-haptic silicone toric intraocular lenses","volume":"34","author":"Chang","year":"2008","journal-title":"J Cataract Refract Surg"}],"container-title":["Advanced Biomedical Research"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.ovid.com\/01679891-201706000-00123","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,8,26]],"date-time":"2026-08-26T19:48:38Z","timestamp":1787773718000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.ovid.com\/01679891-201706000-00123"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2017,1]]},"references-count":14,"journal-issue":{"issue":"1","published-print":{"date-parts":[[2017]]}},"URL":"https:\/\/doi.org\/10.4103\/2277-9175.216777","relation":{},"ISSN":["2277-9175"],"issn-type":[{"value":"2277-9175","type":"electronic"}],"subject":[],"published":{"date-parts":[[2017,1]]},"assertion":[{"value":"2014-02-01","name":"received","label":"Received","group":{"name":"publication_history","label":"Publication History"}},{"value":"2014-05-01","name":"accepted","label":"Accepted","group":{"name":"publication_history","label":"Publication History"}}]}}