{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,20]],"date-time":"2026-10-20T17:52:32Z","timestamp":1792518752732,"version":"4.5.0"},"reference-count":41,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"4","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["J Orthodont Sci"],"published-print":{"date-parts":[[2016]]},"DOI":"10.4103\/2278-0203.192112","type":"journal-article","created":{"date-parts":[[2016,10,13]],"date-time":"2016-10-13T00:06:39Z","timestamp":1476317199000},"page":"109","source":"Crossref","is-referenced-by-count":10,"title":["Effects of intraoral aging of arch-wires on frictional forces: An\n                    <i>ex vivo<\/i>\n                    study"],"prefix":"10.4103","volume":"5","author":[{"given":"Avinash","family":"Kumar","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Arifa","family":"Khanam","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Hajra","family":"Ghafoor","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"276","reference":[{"key":"key-10.4103\/2278-0203.192112-1","first-page":"364","article-title":"Clinical considerations in the use of retraction mechanics","author":"Staggers","year":"1991","journal-title":"J Clin Orthod"},{"key":"key-10.4103\/2278-0203.192112-2","doi-asserted-by":"crossref","first-page":"341","DOI":"10.1016\/0889-5406(91)70072-5","article-title":"Static frictional force and surface roughness of NiTi arch wires","author":"Prososki","year":"1991","journal-title":"Am J Orthod Dentofac Orthop"},{"key":"key-10.4103\/2278-0203.192112-3","doi-asserted-by":"crossref","first-page":"403","DOI":"10.1016\/j.ajodo.2004.09.015","article-title":"Intraoral aging of orthodontic materials: The picture we miss and its clinical relevance","author":"Eliades","year":"2005","journal-title":"Am J Orthod Dentofacial Orthop"},{"key":"key-10.4103\/2278-0203.192112-4","doi-asserted-by":"crossref","first-page":"117","DOI":"10.1016\/0889-5406(90)70005-W","article-title":"Evaluation of friction between edgewise stainless steel brackets and orthodontic wires of four alloys","author":"Kapila","year":"1990","journal-title":"Am J Ortho Dentofac Orthop"},{"key":"key-10.4103\/2278-0203.192112-5","first-page":"66","article-title":"Comparative Evaluation of Friction Resistance of Titanium, Stainless Steel, Ceramic and Ceramic with Metal Insert Brackets with Varying Dimensions of Stainless Steel Wire: An in vitro multi-center Study","author":"Kumar","year":"2014","journal-title":"J Int Oral Health","ISSN":"https:\/\/id.crossref.org\/issn\/0976-7428","issn-type":"print"},{"key":"key-10.4103\/2278-0203.192112-6","doi-asserted-by":"crossref","first-page":"513","DOI":"10.1016\/0889-5406(91)70091-A","article-title":"A comparative study of frictional forces between orthodontic brackets and archwires","author":"Bednar","year":"1991","journal-title":"Am J Orthod Dentofac Orthop"},{"key":"key-10.4103\/2278-0203.192112-7","doi-asserted-by":"crossref","first-page":"416","DOI":"10.1067\/mod.2003.14","article-title":"The effect of ligation method on friction in sliding mechanics","author":"Hain","year":"2003","journal-title":"Am J Orthod Dentofac Orthop"},{"key":"key-10.4103\/2278-0203.192112-8","first-page":"91","article-title":"Frictional resistance between orthodontic brackets and archwire: An in vitro study","author":"Husain","year":"2011","journal-title":"J Contemp Dent Pract"},{"key":"key-10.4103\/2278-0203.192112-9","first-page":"16","article-title":"Orthodontic attachment corrosion susceptibilities","author":"Matasa","year":"1995","journal-title":"J Clin Orthod"},{"key":"key-10.4103\/2278-0203.192112-10","doi-asserted-by":"crossref","first-page":"521","DOI":"10.2319\/081109-457.1","article-title":"Debris, roughness and friction of stainless steel archwires following clinical use","author":"Marques","year":"2010","journal-title":"Angle Orthod"},{"key":"key-10.4103\/2278-0203.192112-11","first-page":"41","article-title":"Surface Roughness of Orthodontic Archwires via Laser Spectroscopy","author":"Kusy","year":"1988","journal-title":"Angle Orthod"},{"key":"key-10.4103\/2278-0203.192112-12","first-page":"4","article-title":"Surface corrosion of Nitinol and Stainless steel under clinical conditions","author":"Edie","year":"1981","journal-title":"Angle Orthod"},{"key":"key-10.4103\/2278-0203.192112-13","doi-asserted-by":"crossref","first-page":"236","DOI":"10.1016\/j.sodo.2003.08.004","article-title":"Friction: Validation of manufacturer\u2032s claim","author":"Mendes","year":"2003","journal-title":"Semin Orthod"},{"key":"key-10.4103\/2278-0203.192112-14","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1016\/S0889-5406(97)70295-6","article-title":"Force decay and deformation of orthodontic elastomeric ligatures","author":"Taloumis","year":"1997","journal-title":"Am J Orthod Dentofac Orthop"},{"key":"key-10.4103\/2278-0203.192112-15","doi-asserted-by":"crossref","first-page":"141","DOI":"10.2319\/052110-276.1","article-title":"Effects of a diamond like carbon coating on the frictional properties of orthodontic wires","author":"Muguruma","year":"2011","journal-title":"Angle Orthod"},{"key":"key-10.4103\/2278-0203.192112-16","doi-asserted-by":"crossref","first-page":"410","DOI":"10.1093\/ejo\/cjr011","article-title":"The effect of Teflon coating on the resistance to sliding of orthodontic archwires","author":"Farronato","year":"2012","journal-title":"Eur J Orthod"},{"key":"key-10.4103\/2278-0203.192112-17","doi-asserted-by":"crossref","first-page":"938","DOI":"10.1016\/j.dental.2004.11.011","article-title":"The effect of surface treatment and clinical use on friction in NiTi orthodontic wires","author":"Wichelhaus","year":"2005","journal-title":"Dental Materials"},{"key":"key-10.4103\/2278-0203.192112-18","doi-asserted-by":"crossref","first-page":"665","DOI":"10.2319\/081213-593.1","article-title":"Effects of intraoral aging on surface properties of coated nickel-titanium archwires","author":"Rongo","year":"2014","journal-title":"Angle Orthod"},{"key":"key-10.4103\/2278-0203.192112-19","first-page":"215","article-title":"Frictional Resistance between orthodontic brackets and archwires in buccal segments","author":"Taylor","year":"1996","journal-title":"Angle Orthod"},{"key":"key-10.4103\/2278-0203.192112-20","doi-asserted-by":"crossref","first-page":"74","DOI":"10.1016\/j.ajodo.2009.02.031","article-title":"Static frictional force and surface roughness of various bracket and wire combinations","author":"Doshi","year":"2011","journal-title":"Am J Orthod Dentofac Orthop"},{"key":"key-10.4103\/2278-0203.192112-21","doi-asserted-by":"crossref","first-page":"399","DOI":"10.1002\/sca.21225","article-title":"Correlation between frictional force and surface roughness of orthodontic archwires","author":"Choi","year":"2015","journal-title":"Scanning"},{"key":"key-10.4103\/2278-0203.192112-22","doi-asserted-by":"crossref","first-page":"44","DOI":"10.4103\/0976-237X.149291","article-title":"Estimation of changes in nickel and chromium content in nickel titanium and stainless steel orthodontic wires used during orthodontic treatment: An analytical and scanning electron microscopic study","author":"Kararia","year":"2015","journal-title":"Contemp Clin Dent,"},{"key":"key-10.4103\/2278-0203.192112-23","unstructured":"Proffit WR. Mechanical principles in orthodontic force control. In: Proffit WR, Fields HW, Sarver DM. Contemporary orthodontics. 5 th ed. St Louis: Mosby Elsevier; 2013. p. 332-3."},{"key":"key-10.4103\/2278-0203.192112-24","doi-asserted-by":"crossref","first-page":"67","DOI":"10.1016\/j.ajodo.2008.07.023","article-title":"In-vitro evaluation of frictional resistance with 5 ligation methods and Gianelly type working Wires","author":"Kahlon","year":"2010","journal-title":"Am J Orthod Dentofac Orthop"},{"key":"key-10.4103\/2278-0203.192112-25","doi-asserted-by":"crossref","first-page":"797","DOI":"10.1002\/1097-4636(20001215)52:4<797::AID-JBM25>3.0.CO;2-9","article-title":"Resistance to sliding of orthodontic appliances in the dry and wet states: Influence of archwire alloy, interbracket distance, and bracket engagement","author":"Kusy","year":"2000","journal-title":"J Biomed Mater Res"},{"key":"key-10.4103\/2278-0203.192112-26","doi-asserted-by":"crossref","first-page":"100","DOI":"10.1016\/0889-5406(89)90251-5","article-title":"Mechanical properties and clinical applications of orthodontic wires","author":"Kapila","year":"1989","journal-title":"Am J Orthod Dentofacial Orthop"},{"key":"key-10.4103\/2278-0203.192112-27","doi-asserted-by":"crossref","first-page":"623","DOI":"10.1016\/j.ajodo.2009.01.032","article-title":"Physical, mechanical, and flexural properties of 3 orthodontic wires: An in-vitro study","author":"Juvvadi","year":"2010","journal-title":"Am J Orthod Dentofacial Orthop"},{"key":"key-10.4103\/2278-0203.192112-28","doi-asserted-by":"crossref","first-page":"367","DOI":"10.5405\/jmbe.700","article-title":"Surface Roughness and Topography of Four Commonly Used Types of Orthodontic Archwire","author":"Yu","year":"2011","journal-title":"J Med Biol Eng"},{"key":"key-10.4103\/2278-0203.192112-29","doi-asserted-by":"crossref","first-page":"922","DOI":"10.2319\/100211-620.1","article-title":"Evaluation of surface roughness of Orthodontic wires by means of Atomic force Microscopy","author":"D\u2032Anto","year":"2012","journal-title":"Angle Orthod"},{"key":"key-10.4103\/2278-0203.192112-30","doi-asserted-by":"crossref","first-page":"129","DOI":"10.4041\/kjod.2012.42.3.129","article-title":"Variations in surface roughness of seven orthodontic archwires: An SEM-profilometry study","author":"Amini","year":"2012","journal-title":"Korean J Orthod"},{"key":"key-10.4103\/2278-0203.192112-31","first-page":"994","article-title":"Coating stability and surface characteristics of esthetic orthodontic coated archwires","author":"Lopes","year":"2013","journal-title":"Angle Orthod"},{"key":"key-10.4103\/2278-0203.192112-32","doi-asserted-by":"crossref","first-page":"39","DOI":"10.1186\/s40510-014-0039-8","article-title":"A new esthetic fiber reinforced polymer composite resin archwire: A comparative atomic force","author":"Chng","year":"2014","journal-title":"Prog Orthod"},{"key":"key-10.4103\/2278-0203.192112-33","doi-asserted-by":"crossref","first-page":"S340","DOI":"10.1016\/j.mjafi.2013.12.006","article-title":"Surface characterization of nickel titanium orthodontic arch wires","author":"Krishnan","year":"2015","journal-title":"Med J Armed Forces Ind"},{"key":"key-10.4103\/2278-0203.192112-34","first-page":"912","article-title":"Effects of Surface Roughness on the Coefficients of Friction in model Orthodontic Systems","author":"Kusy","year":"1990","journal-title":"J Biomechanics"},{"key":"key-10.4103\/2278-0203.192112-35","doi-asserted-by":"crossref","first-page":"409","DOI":"10.1093\/ejo\/22.4.409","article-title":"Influence of ceramic and stainless steel brackets on the notching of archwires during clinical treatment","author":"Articolo","year":"2000","journal-title":"Eur J Orthod"},{"key":"key-10.4103\/2278-0203.192112-36","doi-asserted-by":"crossref","first-page":"317","DOI":"10.1093\/ejo\/22.3.317","article-title":"Surface characterization of retrieved NiTi orthodontic archwires","author":"Eliades","year":"2000","journal-title":"Eur J Orthod"},{"key":"key-10.4103\/2278-0203.192112-37","doi-asserted-by":"crossref","first-page":"661","DOI":"10.1093\/ejo\/cjn057","article-title":"Ex vivo surface and mechanical properties of coated orthodontic Archwires","author":"Elayyan","year":"2008","journal-title":"Eur J Orthod;"},{"key":"key-10.4103\/2278-0203.192112-38","first-page":"31:260","article-title":"Morphological characterization of as-received and in vivo orthodontic stainless steel archwires","author":"Daems","year":"2009","journal-title":"Eur J Orthod"},{"key":"key-10.4103\/2278-0203.192112-39","doi-asserted-by":"crossref","first-page":"223","DOI":"10.1093\/ejo\/cjr104","article-title":"Archwire cleaning after intraoral ageing: The effects on debris, roughness, and friction","author":"Normando","year":"2013","journal-title":"Eur J Orthod"},{"key":"key-10.4103\/2278-0203.192112-40","doi-asserted-by":"crossref","first-page":"79","DOI":"10.1093\/ejo\/20.1.79","article-title":"Surface roughness of orthodontic wires via atomic force microscopy, laser specular reflectance, and profilometry","author":"Bourauel","year":"1998","journal-title":"Eur J Orthod"},{"key":"key-10.4103\/2278-0203.192112-41","doi-asserted-by":"crossref","first-page":"1039","DOI":"10.1016\/j.dental.2009.03.003","article-title":"Nanoindentation of orthodontic archwires: The effect of decontamination and clinical use on hardness, elastic modulus and surface roughness","author":"Alcock","year":"2009","journal-title":"Dental Materials"}],"container-title":["journal of orthodontic science"],"original-title":[],"language":"en","deposited":{"date-parts":[[2026,8,14]],"date-time":"2026-08-14T13:28:16Z","timestamp":1786714096000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.ovid.com\/10.4103\/2278-0203.192112"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2016]]},"references-count":41,"journal-issue":{"issue":"4","published-print":{"date-parts":[[2016]]}},"alternative-id":["192112"],"URL":"https:\/\/doi.org\/10.4103\/2278-0203.192112","relation":{},"ISSN":["2278-0203"],"issn-type":[{"value":"2278-0203","type":"print"}],"subject":[],"published":{"date-parts":[[2016]]}}}