{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,8,19]],"date-time":"2026-08-19T20:02:46Z","timestamp":1787169766056,"version":"build-2736575974"},"reference-count":16,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"3","content-domain":{"domain":["lww.com","ovid.com"],"crossmark-restriction":true},"short-container-title":[],"published-print":{"date-parts":[[2021,7]]},"abstract":"<jats:sec>\n                    <jats:title\/>\n                    <jats:p>The incidence aortic valve injury during percutaneous coronary intervention is scarce, mostly resulting in acute aortic regurgitation. However, rarely patients may remain asymptomatic in the immediate post-procedure period and present latter with chronic aortic regurgitation. Determining etiology of such an aortic regurgitation may be challenging. We present a case of a 51-year-old man with history of percutaneous coronary intervention for coronary artery disease and moderate aortic regurgitation scheduled for coronary artery bypass grafting and aortic valve replacement. Intra-operative transesophageal echocardiography was instrumental in deciding etiology of aortic regurgitation that change surgical management of the patient.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.4103\/aca.aca_125_20","type":"journal-article","created":{"date-parts":[[2023,3,31]],"date-time":"2023-03-31T06:11:56Z","timestamp":1680243116000},"page":"392-395","update-policy":"https:\/\/doi.org\/10.1097\/lww.0000000000001000","source":"Crossref","is-referenced-by-count":5,"title":["Iatrogenic aortic regurgitation following percutaneous coronary intervention"],"prefix":"10.4103","volume":"24","author":[{"given":"Avneet","family":"Singh","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Bhupesh","family":"Kumar","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Gurpinder Singh","family":"Ghotra","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Vikas","family":"Kumar","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Shyam K S","family":"Thingnam","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"276","reference":[{"key":"R1-24-20240901","doi-asserted-by":"crossref","first-page":"204","DOI":"10.1111\/jocs.14272","article-title":"Rare case of iatrogenic aortic valve leaflet tear following a diagnostic coronary angiogram","volume":"35","author":"Madigan","year":"2020","journal-title":"J Card Surg"},{"key":"R2-24-20240901","doi-asserted-by":"crossref","first-page":"155","DOI":"10.1111\/j.1540-8191.1988.tb00233.x","article-title":"Pericardial patch repair of aortic cusp perforation caused by cardiac catheterization","volume":"3","author":"Denyer","year":"1988","journal-title":"J Card Surg"},{"key":"R3-24-20240901","doi-asserted-by":"crossref","first-page":"1765","DOI":"10.1016\/j.athoracsur.2006.12.054","article-title":"Aortic valve as a victim of percutaneous coronary angioplasty and stenting","volume":"84","author":"Kotoulas","year":"2007","journal-title":"Ann Thorac Surg"},{"key":"R4-24-20240901","doi-asserted-by":"crossref","first-page":"485","DOI":"10.1111\/j.1540-8191.2011.01306.x","article-title":"Repair of iatrogenic aortic regurgitation following cardiac catheterization","volume":"26","author":"Bouabdallaoui","year":"2011","journal-title":"J Card Surg"},{"key":"R5-24-20240901","doi-asserted-by":"crossref","first-page":"e8","DOI":"10.1161\/CIRCINTERVENTIONS.110.960369","article-title":"Severe aortic regurgitation after transradial percutaneous coronary intervention","volume":"4","author":"Ong","year":"2011","journal-title":"Circ Cardiovasc Interv"},{"key":"R6-24-20240901","doi-asserted-by":"crossref","first-page":"501","DOI":"10.1016\/j.recesp.2016.07.020","article-title":"Percutaneous coronary intervention: A rare cause of acute traumatic aortic regurgitation","volume":"70","author":"Gamaza Chuli\u00e1n","year":"2017","journal-title":"Rev Esp Cardiol (Engl Ed"},{"key":"R7-24-20240901","doi-asserted-by":"crossref","first-page":"205","DOI":"10.1510\/icvts.2010.252155","article-title":"Aortic valve lesion after coronary angiography","volume":"12","author":"Rolf","year":"2011","journal-title":"Interact Cardiovasc Thorac Surg"},{"key":"R8-24-20240901","doi-asserted-by":"crossref","first-page":"984","DOI":"10.1016\/j.jcin.2010.04.018","article-title":"Aortic regurgitation after cardiac catheterization","volume":"3","author":"Safar","year":"2010","journal-title":"JACC Cardiovasc Interv"},{"key":"R9-24-20240901","first-page":"366","article-title":"Lambl\u2019s excrescences: Review and recommendations","volume":"3","author":"Aziz","year":"2007","journal-title":"Tex Heart Inst J"},{"key":"R10-24-20240901","doi-asserted-by":"crossref","first-page":"784","DOI":"10.1016\/S0735-1097(97)00211-8","article-title":"Papillary fibroelastoma: Echocardiographic characteristics for diagnosis and pathologic correlation","volume":"30","author":"Klarich","year":"1997","journal-title":"J Am Coll Cardiol"},{"key":"R11-24-20240901","doi-asserted-by":"crossref","first-page":"647","DOI":"10.1016\/j.athoracsur.2005.03.060","article-title":"Results of aortic valve-sparing and restoration with autologous pericardial leaflet extensions in congenital heart disease","volume":"80","author":"Odim","year":"2005","journal-title":"Ann Thorac Surg"},{"key":"R12-24-20240901","doi-asserted-by":"crossref","first-page":"946","DOI":"10.1016\/j.athoracsur.2007.10.037","article-title":"Single cusp replacement for aortic regurgitation","volume":"85","author":"Tao","year":"2008","journal-title":"Ann Thorac Surg"},{"key":"R13-24-20240901","doi-asserted-by":"crossref","first-page":"331","DOI":"10.21037\/acs.2019.05.15","article-title":"Systematic echocardiographic assessment of aortic regurgitation- What should the surgeon know for aortic valve repair?","volume":"8","author":"Berrebi","year":"2019","journal-title":"Ann Cardiothorac Surg"},{"key":"R14-24-20240901","first-page":"268","article-title":"Perioperative echocardiography in Ozaki\u2019s procedure: An observational study-Single centre experience. MedPulse International Journal of Anesthesiology","volume":"11","author":"Pushpa","year":"2019","journal-title":"September"},{"key":"R15-24-20240901","doi-asserted-by":"crossref","first-page":"931","DOI":"10.1016\/j.jcmg.2009.04.013","article-title":"Mechanisms of recurrent aortic regurgitation after aortic valve repair: Predictive value of intraoperative transesophageal echocardiography","volume":"2","author":"Le Polain de Waroux","year":"2009","journal-title":"JACC Cardiovasc Imaging"},{"key":"R16-24-20240901","doi-asserted-by":"crossref","first-page":"178","DOI":"10.1161\/CIRCULATIONAHA.109.934679","article-title":"Valve configuration determines long-term results after repair of the bicuspid aortic valve","volume":"123","author":"Aicher","year":"2011","journal-title":"Circulation"}],"container-title":["Annals of Cardiac Anaesthesia"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.ovid.com\/10.4103\/aca.ACA_125_20","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,8,19]],"date-time":"2026-08-19T19:13:04Z","timestamp":1787166784000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.ovid.com\/10.4103\/aca.ACA_125_20"}},"subtitle":["Role of transesophageal echocardiography in the detection and management"],"short-title":[],"issued":{"date-parts":[[2021,7]]},"references-count":16,"journal-issue":{"issue":"3","published-print":{"date-parts":[[2021]]}},"URL":"https:\/\/doi.org\/10.4103\/aca.aca_125_20","relation":{},"ISSN":["0971-9784"],"issn-type":[{"value":"0971-9784","type":"print"}],"subject":[],"published":{"date-parts":[[2021,7]]}}}