{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,8,26]],"date-time":"2026-08-26T16:35:08Z","timestamp":1787762108255,"version":"build-2784847793"},"reference-count":37,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"2","content-domain":{"domain":["lww.com","ovid.com"],"crossmark-restriction":true},"short-container-title":[],"published-print":{"date-parts":[[2023,4]]},"abstract":"<jats:title>ABSTRACT<\/jats:title>\n                  <jats:p>Appropriate size selection of double-lumen tubes (DLTs) for one-lung ventilation (OLV) in adults is still a humongous task. Several important factors are to be considered like patient height, gender, tracheal diameter, left main bronchial diameter, and cricoid cartilage transverse diameter. In addition to radiological assessment of the airway diameters, the manufacturing details of the particular DLT being used also play a significant role in size selection. Optimal positioning of the appropriately sized DLT is indispensable to avoid complications like airway trauma, cuff rupture, hypoxemia, and tube displacement. It is imperative to know whether the one-size-fits-all dictum holds for DLT size selection as claimed by certain studies. Further randomized studies are required for crystallizing standard protocols ascertaining the correct DLT size. This systematic review article highlights the various parameters employed for DLT size selection and explores the newer DLTs used for adult OLV.<\/jats:p>","DOI":"10.4103\/aca.aca_140_22","type":"journal-article","created":{"date-parts":[[2023,6,20]],"date-time":"2023-06-20T03:00:34Z","timestamp":1687230034000},"page":"124-132","update-policy":"https:\/\/doi.org\/10.1097\/lww.0000000000001000","source":"Crossref","is-referenced-by-count":22,"title":["Choosing the Correct-Sized Adult Double-Lumen Tube: Quest for the Holy Grail"],"prefix":"10.4103","volume":"26","author":[{"given":"Shagun Bhatia","family":"Shah","sequence":"first","affiliation":[{"name":"Department of Anaesthesia and Critical Care, Rajiv Gandhi Cancer Institute and Research Centre, Rohini, New Delhi, India"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Uma","family":"Hariharan","sequence":"additional","affiliation":[{"name":"Department of Anaesthesiology, Atal Bihari Vajpayee Institute of Medical Sciences and Dr Ram Manohar Lohia Hospital, CHS, New Delhi, India"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Rajiv","family":"Chawla","sequence":"additional","affiliation":[{"name":"Department of Anaesthesia and Critical Care, Rajiv Gandhi Cancer Institute and Research Centre, Rohini, New Delhi, India"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"276","published-online":{"date-parts":[[2023,4,3]]},"reference":[{"key":"R1-20240901","doi-asserted-by":"crossref","first-page":"1485","DOI":"10.1213\/ANE.0000000000004669","article-title":"Airway rupture caused by double-lumen tubes:A review of 187 cases","volume":"131","author":"Liu","year":"2020","journal-title":"Anesth Analg"},{"key":"R2-20240901","doi-asserted-by":"crossref","first-page":"117","DOI":"10.1016\/S1053-0770(05)80179-X","article-title":"Choosing the appropriate double lumen tube:A glimmer of science comes to a dark art","volume":"9","author":"Slinger","year":"1995","journal-title":"J Cardiothorac Vasc Anesth"},{"key":"R3-20240901","doi-asserted-by":"crossref","first-page":"412","DOI":"10.1016\/S1053-0770(03)00077-6","article-title":"The height-based formula for prediction of left-sided double-lumen tracheal tube depth","volume":"17","author":"Takita","year":"2003","journal-title":"J Cardiothorac Vasc Anesth"},{"key":"R4-20240901","doi-asserted-by":"crossref","first-page":"158","DOI":"10.1213\/00000539-199807000-00033","article-title":"Predicting the size of a double-lumen endobronchial tube based on tracheal diameter","volume":"87","author":"Chow","year":"1998","journal-title":"Anesth Analg"},{"key":"R5-20240901","doi-asserted-by":"crossref","first-page":"168","DOI":"10.1016\/S1053-0770(97)90208-1","article-title":"Evaluation of an approach to choosing a left doublelumen tube size based on chest computed tomographic scan measurement of left mainstem bronchial diameter","volume":"11","author":"Hannallah","year":"1997","journal-title":"J Cardiothorac Vasc Anesth"},{"key":"R6-20240901","doi-asserted-by":"crossref","first-page":"231","DOI":"10.1097\/00003643-201206001-00768","article-title":"Double lumen endobronchial tube (DLT) sizes in routine practice:19AP2-7","volume":"29","author":"Duthie","year":"2012","journal-title":"Euro J Anaesthesiol"},{"key":"R7-20240901","doi-asserted-by":"crossref","first-page":"28","DOI":"10.4103\/0971-9784.197824","article-title":"Selection of an appropriate left-sided double-lumen tube size for one-lung ventilation among Asians","volume":"20","author":"Ideris","year":"2017","journal-title":"Ann Card Anaesth"},{"key":"R8-20240901","doi-asserted-by":"crossref","first-page":"215","DOI":"10.1097\/EJA.0000000000000939","article-title":"Use of tracheal ultrasound combined with clinical parameters to select left double-lumen tube size:A prospective observational study","volume":"36","author":"Roldi","year":"2019","journal-title":"Eur J Anaesthesiol"},{"key":"R9-20240901","first-page":"861","article-title":"Tracheal diameter predicts double-lumen tube size:A method for selecting left double-lumen tubes","volume":"82","author":"Brodsky","year":"1996","journal-title":"Anesth Analg"},{"key":"R10-20240901","doi-asserted-by":"crossref","first-page":"540","DOI":"10.1177\/0310057X0002800510","article-title":"Estimating the diameter of the left main bronchus","volume":"28","author":"Hampton","year":"2000","journal-title":"Anaesth Intensive Care"},{"key":"R11-20240901","doi-asserted-by":"crossref","first-page":"267","DOI":"10.1016\/j.jclinane.2004.07.008","article-title":"Tracheal width and left double-lumen tube size:A formula to estimate left-bronchial width","volume":"17","author":"Brodsky","year":"2005","journal-title":"J Clin Anesth"},{"key":"R12-20240901","doi-asserted-by":"crossref","first-page":"247","DOI":"10.1016\/j.jclinane.2007.11.002","article-title":"Can ultrasound be useful for predicting the size of a left double-lumen bronchial tube?Tracheal width as measured by ultrasonography versus computed tomography","volume":"20","author":"\u0160usti\u0107","year":"2008","journal-title":"J Clin Anesth"},{"key":"R13-20240901","doi-asserted-by":"crossref","first-page":"302","DOI":"10.1213\/00000539-199902000-00014","article-title":"Predicting the size of a double-lumen endobronchial tube using computed tomographic scan measurements of the left main bronchus diameter","volume":"88","author":"Chow","year":"1999","journal-title":"Anesth Analg"},{"key":"R14-20240901","first-page":"799","article-title":"Analysis of the association between double-lumen endobronchial tube and inner diameter of the left main bronchus","volume":"25","author":"Cui","year":"2005","journal-title":"Acad J First Med Col PLA"},{"key":"R15-20240901","doi-asserted-by":"crossref","first-page":"59","DOI":"10.1177\/0310057X0503300109","article-title":"A new technique to determine the size of double-lumen endobronchial tubes by the two perpendicularly measured bronchial diameters","volume":"33","author":"Jeon","year":"2005","journal-title":"Anaesth Intensive Care"},{"key":"R16-20240901","doi-asserted-by":"crossref","first-page":"863","DOI":"10.1053\/j.jvca.2017.10.008","article-title":"Computed tomographic window setting for bronchial measurement to guide double-lumen tube size","volume":"32","author":"Seo","year":"2018","journal-title":"J Cardiothorac Vasc Anesth"},{"key":"R17-20240901","doi-asserted-by":"crossref","first-page":"51","DOI":"10.4103\/aca.ACA_11_18","article-title":"Practice patterns of left-sided double-lumen tube:Does it match recommendation from literature\u2013A single-centre observational pilot study","volume":"22","author":"Kar","year":"2019","journal-title":"Ann Cardiac Anaesth"},{"key":"R18-20240901","doi-asserted-by":"crossref","first-page":"358","DOI":"10.4103\/aca.ACA_117_18","article-title":"Comparison between computerized tomography-guided bronchial width measurement versus conventional method for selection of adequate double lumen tube size","volume":"22","author":"Suvvari","year":"2019","journal-title":"Ann Cardiac Anaesth"},{"key":"R19-20240901","doi-asserted-by":"crossref","first-page":"379","DOI":"10.1213\/ane.0b013e3181602e41","article-title":"Practice patterns in choice of left double-lumen tube size for thoracic surgery","volume":"106","author":"Amar","year":"2008","journal-title":"Anesth Analg"},{"key":"R20-20240901","doi-asserted-by":"crossref","first-page":"42","DOI":"10.4103\/aca.ACA_93_19","article-title":"Comparison of different size left-sided double-lumen tubes for thoracic surgery","volume":"24","author":"Nguyen","year":"2021","journal-title":"Ann Card Anaesth"},{"key":"R21-20240901","doi-asserted-by":"crossref","first-page":"299","DOI":"10.1016\/S1053-0770(03)00057-0","article-title":"The relationship between the diameters of the adult cricoid ring and main tracheobronchial tree:A cadaver study to investigate the basis for double-lumen tube selection","volume":"17","author":"Seymour","year":"2003","journal-title":"J Cardiothorac Vasc Anesth"},{"key":"R22-20240901","doi-asserted-by":"crossref","first-page":"762","DOI":"10.1213\/ANE.0000000000003839","article-title":"Predicting the size of a left double-lumen tube for Asian women based on the combination of the diameters of the cricoid ring and left main bronchus:A randomized, prospective, controlled trial","volume":"130","author":"Shiqing","year":"2020","journal-title":"Anesth Analg"},{"key":"R23-20240901","doi-asserted-by":"crossref","first-page":"1410","DOI":"10.1053\/j.jvca.2020.07.077","article-title":"Prediction of double-lumen tube size by ultrasonography for Asian women:A prospective observational study","volume":"35","author":"Shiqing","year":"2021","journal-title":"J Cardiothorac Vasc Anesth"},{"key":"R24-20240901","doi-asserted-by":"crossref","first-page":"657612","DOI":"10.3389\/fmed.2021.657612","article-title":"Prediction of left double-lumen tube size by measurement of cricoid cartilage transverse diameter by ultrasound and ct multi-planar reconstruction","volume":"8","author":"Zhang","year":"2021","journal-title":"Front Med (Lausanne)"},{"key":"R26-20240901","doi-asserted-by":"crossref","first-page":"287","DOI":"10.1016\/S1053-0770(03)00058-2","article-title":"A view of and through double-lumen tubes","volume":"17","author":"Slinger","year":"2003","journal-title":"J Cardiothorac Vasc Anesth"},{"key":"R27-20240901","doi-asserted-by":"crossref","first-page":"50","DOI":"10.1177\/0310057X0303100109","article-title":"Dimensions of double-lumen tracheobronchial tubes","volume":"31","author":"Russell","year":"2003","journal-title":"Anaesth Intensiv Care"},{"key":"R28-20240901","doi-asserted-by":"crossref","first-page":"119","DOI":"10.1016\/S1053-0770(05)80180-6","article-title":"The relationship between left mainstem bronchial diameter and patient size","volume":"9","author":"Hannallah","year":"1995","journal-title":"J Cardiothor Vasc Anesth"},{"key":"R29-20240901","doi-asserted-by":"crossref","first-page":"393","DOI":"10.4103\/ija.IJA_13_17","article-title":"Difficulty in inserting left double-lumen endobronchial tubes at the cricoid level in small-statured women:A retrospective study","volume":"61","author":"Sato","year":"2017","journal-title":"Indian J Anaesth"},{"key":"R30-20240901","first-page":"210","article-title":"The dimensional interrelationships of the major components of the human tracheobronchial tree","volume":"105","author":"Jesseph","year":"1957","journal-title":"Surg Gynecol Obstet"},{"key":"R31-20240901","first-page":"3634202","article-title":"Dimensional variations of left-sided double-lumen endobronchial tubes","volume":"2019","author":"Hegland","year":"2019","journal-title":"Anesthesiol Res Pract"},{"key":"R33-20240901","doi-asserted-by":"crossref","first-page":"177","DOI":"10.1186\/s12871-022-01698-2","article-title":"Comparisons of the segments of left-sided double-lumen tracheobronchial tubes as industrial products","volume":"22","author":"Wajima","year":"2022","journal-title":"BMC Anesthesiol"},{"key":"R34-20240901","doi-asserted-by":"crossref","first-page":"101","DOI":"10.1378\/chest.130.1.101","article-title":"Measurement of left mainstem bronchus using multiplane CT reconstructions and relationship between patient characteristics or tracheal diameters and left bronchial diameters","volume":"130","author":"Olivier","year":"2006","journal-title":"Chest"},{"key":"R35-20240901","doi-asserted-by":"crossref","first-page":"532","DOI":"10.1016\/S1053-0770(99)90003-4","article-title":"Computed tomography-based tracheobronchial image reconstruction allows selection of the individually appropriate double-lumen tube size","volume":"13","author":"Eberle","year":"1999","journal-title":"J Cardiothorac Vasc Anesth"},{"key":"R36-20240901","doi-asserted-by":"crossref","first-page":"1281","DOI":"10.23736\/S0375-9393.19.13458-X","article-title":"Automated measurement of tracheal and main bronchial diameters:A feasibility study","volume":"85","author":"Ma","year":"2019","journal-title":"Minerva Anestesiol"},{"key":"R37-20240901","doi-asserted-by":"crossref","first-page":"1259","DOI":"10.1111\/anae.13177","article-title":"Comparison of VivaSight double lumen tube with a conventional double lumen tube in adult patients undergoing video-assisted thoracoscopic surgery","volume":"70","author":"Levy-Faber","year":"2015","journal-title":"Anaesthesia"},{"key":"R38-20240901","doi-asserted-by":"crossref","first-page":"279","DOI":"10.4103\/aca.aca_43_21","article-title":"Intubation with vivasight double-lumen tube versus conventional double-lumen tube in adult patients undergoing lung resection:A retrospective analysis","volume":"25","author":"Granell","year":"2022","journal-title":"Ann Card Anaesth"},{"key":"R39-20240901","doi-asserted-by":"crossref","first-page":"977","DOI":"10.3390\/jcm9040977","article-title":"A randomized controlled trial comparing novel triple-cuffed double-lumen endobronchial tubes with conventional double-lumen endobronchial tubes for lung isolation","volume":"9","author":"Kim","year":"2020","journal-title":"J Clin Med"}],"container-title":["Annals of Cardiac Anaesthesia"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.ovid.com\/10.4103\/aca.aca_140_22","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,8,26]],"date-time":"2026-08-26T16:14:43Z","timestamp":1787760883000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.ovid.com\/10.4103\/aca.aca_140_22"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2023,4]]},"references-count":37,"journal-issue":{"issue":"2","published-print":{"date-parts":[[2023]]}},"URL":"https:\/\/doi.org\/10.4103\/aca.aca_140_22","relation":{},"ISSN":["0971-9784","0974-5181"],"issn-type":[{"value":"0971-9784","type":"print"},{"value":"0974-5181","type":"electronic"}],"subject":[],"published":{"date-parts":[[2023,4]]},"assertion":[{"value":"2022-08-15","name":"received","label":"Received","group":{"name":"publication_history","label":"Publication History"}},{"value":"2022-10-12","name":"accepted","label":"Accepted","group":{"name":"publication_history","label":"Publication History"}}]}}