{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,23]],"date-time":"2026-09-23T04:12:05Z","timestamp":1790136725501,"version":"4.0.1"},"reference-count":12,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"2","license":[{"start":{"date-parts":[[2025,4,1]],"date-time":"2025-04-01T00:00:00Z","timestamp":1743465600000},"content-version":"unspecified","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by-nc-sa\/4.0"}],"content-domain":{"domain":["lww.com","ovid.com"],"crossmark-restriction":true},"short-container-title":[],"published-print":{"date-parts":[[2025,4]]},"abstract":"<jats:title>ABSTRACT<\/jats:title>\n                  <jats:sec>\n                    <jats:title>Introduction:<\/jats:title>\n                    <jats:p>Elevated endotracheal tube (ETT) cuff pressures during surgery can lead to tracheal ischemia and airway complications, including postoperative sore throat, subglottic edema, and tracheal stenosis. The insertion of a transesophageal echocardiography (TEE) probe, commonly used in cardiac surgeries, may increase ETT cuff pressure due to its proximity to the trachea. This study assesses the impact of TEE probe insertion on ETT cuff pressures and related postoperative airway complications in patients undergoing coronary artery bypass graft (CABG) surgery.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Methods:<\/jats:title>\n                    <jats:p>In this prospective, randomized controlled trial, 40 patients undergoing CABG were assigned to either a control group (Group C, n = 20) or an intervention group (Group T, n = 20). Cuff pressures were monitored at baseline (T1), during TEE probe manipulation (T2), after initial examination (T3), and during recovery (T4). In Group T, cuff pressures were adjusted to 20-30 cmH2O if they exceeded 30 cmH2O during T2 and T3. Postoperative complications, including sore throat, hoarseness, and cough, were assessed using standardized scales.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results:<\/jats:title>\n                    <jats:p>TEE probe manipulation significantly increased ETT cuff pressures in both groups, with lower pressures consistently observed in Group T (P &lt; 0.05). At T3, the mean cuff pressure in Group C was 41.00 cmH2O versus 33.30 cmH2O in Group T (P &lt; 0.001). The control group experienced more severe postoperative airway complications, while Group T had a significantly reduced risk of severe complications (odds ratio &lt; 0.2).<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusion:<\/jats:title>\n                    <jats:p>TEE probe manipulation significantly increases ETT cuff pressures, but cuff deflation during manipulation effectively reduces these pressures and lowers the risk of postoperative airway complications.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.4103\/aca.aca_175_24","type":"journal-article","created":{"date-parts":[[2025,4,16]],"date-time":"2025-04-16T11:00:23Z","timestamp":1744801223000},"page":"143-148","update-policy":"https:\/\/doi.org\/10.1097\/lww.0000000000001000","source":"Crossref","is-referenced-by-count":1,"title":["Effect of Transesophageal Echocardiography Probe Insertion on Endotracheal Tube Cuff Pressure in Patients Undergoing Coronary Artery Bypass Graft (CABG) Surgery. A Prospective Randomized Control Trial"],"prefix":"10.4103","volume":"28","author":[{"given":"A","family":"Kireeti","sequence":"first","affiliation":[{"name":"Department of Anaesthesia, Govt Medical College, Wanaparthy, Telangana, India"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ravikanth","family":"Pula","sequence":"additional","affiliation":[{"name":"Department of Anaesthesia, ESIC MC and SSH, Sanathnagar, Hyderabad, Telangana, India"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"T","family":"Nagarjuna","sequence":"additional","affiliation":[{"name":"Department of Anaesthesia, ESIC MC and SSH, Sanathnagar, Hyderabad, Telangana, India"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"T.","family":"Rabbani","sequence":"additional","affiliation":[{"name":"Department of Anaesthesia, ESIC MC and SSH, Sanathnagar, Hyderabad, Telangana, India"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"R","family":"Gopinath","sequence":"additional","affiliation":[{"name":"Department of Anaesthesia, ESIC MC and SSH, Sanathnagar, Hyderabad, Telangana, India"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"276","published-online":{"date-parts":[[2025,4,16]]},"reference":[{"key":"R1-20250416","doi-asserted-by":"crossref","first-page":"1237","DOI":"10.1136\/bmj.288.6422.965","article-title":"Endotracheal cuff pressure and tracheal mucosal blood flow:An endoscopic study of effects of four large volume cuffs","volume":"288","author":"Seegobin","year":"1984","journal-title":"Br Med J"},{"key":"R2-20250416","doi-asserted-by":"crossref","first-page":"223","DOI":"10.2147\/VHRM.S400117","article-title":"Cardiac anesthesia intraoperative interpretation accuracy of transesophageal echocardiograms:A review of the current literature and meta-analysis","volume":"19","author":"Kawana","year":"2023","journal-title":"Vasc Health Risk Manag"},{"key":"R3-20250416","doi-asserted-by":"crossref","first-page":"181","DOI":"10.5005\/jp-journals-10071-23737","article-title":"Utility of endotracheal tube cuff pressure monitoring in mechanically ventilated (MV) children in preventing post-extubation stridor (PES)","volume":"25","author":"Shaikh","year":"2021","journal-title":"Indian J Crit Care Med"},{"key":"R4-20250416","doi-asserted-by":"crossref","first-page":"1590","DOI":"10.1016\/j.jtcvs.2017.04.091","article-title":"Optimal blood pressure during cardiopulmonary bypass is defined by cerebral autoregulation monitoring","volume":"154","author":"Hori","year":"2017","journal-title":"J Thorac Cardiovasc Surg"},{"key":"R5-20250416","doi-asserted-by":"crossref","first-page":"3090","DOI":"10.1053\/j.jvca.2022.04.014","article-title":"Increased endotracheal tube cuff pressures during transesophageal echocardiography\u2013A hidden risk factor for injury or inconsequential?","volume":"36","author":"Patel","year":"2022","journal-title":"J Cardiothorac Vasc Anesth"},{"key":"R6-20250416","doi-asserted-by":"crossref","first-page":"18192","DOI":"10.1038\/s41598-022-21980-0","article-title":"The impact of esophageal device insertion on cuff pressure of endotracheal tube:A literature review and meta-analysis","volume":"12","author":"Hung","year":"2022","journal-title":"Sci Rep"},{"key":"R7-20250416","doi-asserted-by":"crossref","first-page":"393","DOI":"10.4103\/aca.aca_19_23","article-title":"Effect of transesophageal echocardiography probe on tracheal perfusion pressure and ventilatory parameters in pediatric patients undergoing cardiac surgery using cardiopulmonary bypass:A prospective observational study","volume":"26","author":"Verma","year":"2023","journal-title":"Ann Card Anaesth"},{"key":"R8-20250416","doi-asserted-by":"crossref","first-page":"460","DOI":"10.4103\/aca.ACA_52_19","article-title":"Does the endotracheal tube cuff pressure increase with transesophageal probe insertion?","volume":"23","author":"Borde","year":"2020","journal-title":"Ann Card Anaesth"},{"key":"R9-20250416","doi-asserted-by":"crossref","first-page":"549","DOI":"10.1097\/EJA.0000000000000204","article-title":"Increased tracheal cuff pressure during insertion of a transoesophageal echocardiography probe","volume":"32","author":"Kim","year":"2015","journal-title":"Eur J Anaesthesiol"},{"key":"R10-20250416","first-page":"e42519","article-title":"The effect of endotracheal tube cuff shape on post-extubation sore throat in critically ill patients in a rural tertiary care hospital","volume":"15","author":"Venkatesh","year":"2023","journal-title":"Cureus"},{"key":"R11-20250416","doi-asserted-by":"crossref","first-page":"2356","DOI":"10.1097\/MS9.0000000000000786","article-title":"Incidence and risk factors for postoperative sore throat after general anesthesia with endotracheal intubation:prospective cohort study","volume":"85","author":"Bekele","year":"2023","journal-title":"Ann Med Surg (Lond)"},{"key":"R12-20250416","doi-asserted-by":"crossref","first-page":"3084","DOI":"10.1053\/j.jvca.2022.02.037","article-title":"The effect of intraoperative transesophageal echocardiography probe placement on the endotracheal tube cuff pressure in adult patients undergoing on-pump cardiac surgery","volume":"36","author":"Maddali","year":"2022","journal-title":"J Cardiothorac Vasc Anesth"}],"container-title":["Annals of Cardiac Anaesthesia"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.ovid.com\/10.4103\/aca.aca_175_24","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,8,14]],"date-time":"2026-08-14T19:34:06Z","timestamp":1786736046000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.ovid.com\/10.4103\/aca.aca_175_24"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,4]]},"references-count":12,"journal-issue":{"issue":"2","published-print":{"date-parts":[[2025]]}},"URL":"https:\/\/doi.org\/10.4103\/aca.aca_175_24","relation":{},"ISSN":["0971-9784","0974-5181"],"issn-type":[{"value":"0971-9784","type":"print"},{"value":"0974-5181","type":"electronic"}],"subject":[],"published":{"date-parts":[[2025,4]]},"assertion":[{"value":"2024-08-29","name":"received","label":"Received","group":{"name":"publication_history","label":"Publication History"}},{"value":"2024-11-06","name":"accepted","label":"Accepted","group":{"name":"publication_history","label":"Publication History"}}]}}