{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,8,3]],"date-time":"2026-08-03T13:49:49Z","timestamp":1785764989668,"version":"3.56.0"},"reference-count":8,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"3","license":[{"start":{"date-parts":[[2026,7,1]],"date-time":"2026-07-01T00:00:00Z","timestamp":1782864000000},"content-version":"unspecified","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by-nc-nd\/4.0"}],"content-domain":{"domain":["lww.com","ovid.com"],"crossmark-restriction":true},"short-container-title":[],"published-print":{"date-parts":[[2026,7]]},"abstract":"<jats:title>ABSTRACT<\/jats:title>\n                  <jats:p>This case report tells the story of a 36-year-old overweight male with suspected myocarditis, who goes into cardiac arrest, and is subsequently transported to a heart center for extracorporeal membrane oxygenation. Mechanical support was established and running until distal limb perfusion was attempted. It is suspected that an aspired guidewire of a central venous catheter placed with the Seldinger technique was aspired and eventually obstructed the impeller of the centrifugal pump.<\/jats:p>","DOI":"10.4103\/aca.aca_259_25","type":"journal-article","created":{"date-parts":[[2026,7,13]],"date-time":"2026-07-13T19:00:32Z","timestamp":1783969232000},"page":"421-423","update-policy":"https:\/\/doi.org\/10.1097\/lww.0000000000001000","source":"Crossref","is-referenced-by-count":0,"title":["Guidewire Obstruction of Centrifugal Pump, in Patient on Extracorporeal Circulatory Support"],"prefix":"10.4103","volume":"29","author":[{"given":"Johannes Bladt","family":"Andersen","sequence":"first","affiliation":[{"name":"Department of Cardiothoracic and Vascular Surgery, Odense University Hospital, Odense, Denmark"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Henrik Frederiksen","family":"H\u00f8jgaard","sequence":"additional","affiliation":[{"name":"Department of Cardiothoracic and Vascular Surgery, Odense University Hospital, Odense, Denmark"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Claus","family":"Andersen","sequence":"additional","affiliation":[{"name":"Department of Cardiothoracic and Vascular Surgery, Odense University Hospital, Odense, Denmark"},{"name":"Department of Clinical Medicine, University of Southern Denmark, Denmark"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"276","published-online":{"date-parts":[[2026,7,13]]},"reference":[{"key":"R1-20260803","doi-asserted-by":"crossref","first-page":"47","DOI":"10.1080\/02841850802133386","article-title":"Catheter replacement of the needle in percutaneous arteriography. A new technique","volume":"434","author":"Seldinger","year":"2008","journal-title":"Acta Radiol Suppl (Stockholm)"},{"key":"R2-20260803","doi-asserted-by":"crossref","first-page":"144","DOI":"10.1093\/bja\/88.1.144","article-title":"Loss of the guide wire: Mishap or blunder?","volume":"88","author":"Schummer","year":"2002","journal-title":"Br J Anaesth"},{"key":"R3-20260803","doi-asserted-by":"crossref","first-page":"ytz085","DOI":"10.1093\/ehjcr\/ytz085","article-title":"Aspiration of the guidewire of a central venous jugular catheter by the venous cannula of a veno-arterial extracorporeal membrane oxygenation","volume":"3","author":"Seguin","year":"2019","journal-title":"Eur Heart J Case Rep"},{"key":"R4-20260803","doi-asserted-by":"crossref","first-page":"199","DOI":"10.4266\/acc.2023.01270","article-title":"Transjugular central venous catheter guidewire embolism to venoarterial extracorporeal membrane oxygenation cannula","volume":"39","author":"Devanand","year":"2024","journal-title":"Acute Crit Care"},{"key":"R5-20260803","doi-asserted-by":"crossref","first-page":"e37638","DOI":"10.1097\/MD.0000000000037638","article-title":"Intravascular guide wire aspiration in a patient on extracorporeal membrane oxygenation: A case report","volume":"103","author":"Choi","year":"2024","journal-title":"Medicine (Baltimore)"},{"key":"R6-20260803","doi-asserted-by":"crossref","first-page":"162","DOI":"10.1016\/j.jclinane.2018.11.003","article-title":"ECMO circuit embolism: A potentially hazardous complication during ECMO therapy","volume":"54","author":"Aizawa","year":"2019","journal-title":"J Clin Anesth"},{"key":"R7-20260803","doi-asserted-by":"crossref","first-page":"43","DOI":"10.3390\/reports7020043","article-title":"Guidewire retention by the venous cannula of veno-arterial extracorporeal membrane oxygenation","volume":"7","author":"Bratke","year":"2024","journal-title":"Reports (MDPI)"},{"key":"R8-20260803","first-page":"269","article-title":"Central venous catheter placement during extracorporeal membrane oxygenation therapy","volume":"37","author":"Picard","year":"2018","journal-title":"Anaesth Crit Care Pain Med"}],"container-title":["Annals of Cardiac Anaesthesia"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.ovid.com\/10.4103\/aca.aca_259_25","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,8,3]],"date-time":"2026-08-03T13:09:05Z","timestamp":1785762545000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.ovid.com\/10.4103\/aca.aca_259_25"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,7]]},"references-count":8,"journal-issue":{"issue":"3","published-print":{"date-parts":[[2026]]}},"URL":"https:\/\/doi.org\/10.4103\/aca.aca_259_25","relation":{},"ISSN":["0971-9784","0974-5181"],"issn-type":[{"value":"0971-9784","type":"print"},{"value":"0974-5181","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,7]]},"assertion":[{"value":"2025-09-09","name":"received","label":"Received","group":{"name":"publication_history","label":"Publication History"}},{"value":"2025-10-28","name":"accepted","label":"Accepted","group":{"name":"publication_history","label":"Publication History"}}]}}