{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,8,26]],"date-time":"2026-08-26T20:32:22Z","timestamp":1787776342047,"version":"build-2784847793"},"reference-count":10,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"2","content-domain":{"domain":["lww.com","ovid.com"],"crossmark-restriction":true},"short-container-title":[],"published-print":{"date-parts":[[2017,4]]},"abstract":"<jats:p>We report a case of rheumatic heart disease with severe mitral stenosis having cyanosis and low oxygen saturation on pulse oximetry. The findings of clinical examination and low values on pulse oximetry were inconsistent with the findings of normal partial pressure of oxygen and oxygen saturation on arterial blood gas analysis, leading to diagnostic dilemma. In such clinical scenario, the anesthesiologist should be aware and vigilant about the differential diagnosis of low oxygen saturation on pulse oximetry.<\/jats:p>","DOI":"10.4103\/aca.aca_34_17","type":"journal-article","created":{"date-parts":[[2017,4,6]],"date-time":"2017-04-06T11:15:08Z","timestamp":1491477308000},"page":"262-264","update-policy":"https:\/\/doi.org\/10.1097\/lww.0000000000001000","source":"Crossref","is-referenced-by-count":3,"title":["Diagnostic Dilemma: Low Oxygen Saturation during Cardiac Surgery"],"prefix":"10.4103","volume":"20","author":[{"given":"Suruchi","family":"Ladha","sequence":"first","affiliation":[{"name":"Department of Cardiac Anaesthesia, CNC, AIIMS, New Delhi, India"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Shivani","family":"Aggarwal","sequence":"additional","affiliation":[{"name":"Department of Cardiac Anaesthesia, CNC, AIIMS, New Delhi, India"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Usha","family":"Kiran","sequence":"additional","affiliation":[{"name":"Department of Cardiac Anaesthesia, CNC, AIIMS, New Delhi, India"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Arindam","family":"Choudhary","sequence":"additional","affiliation":[{"name":"Department of Cardiac Anaesthesia, CNC, AIIMS, New Delhi, India"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Poonam Malhotra","family":"Kapoor","sequence":"additional","affiliation":[{"name":"Department of Cardiac Anaesthesia, CNC, AIIMS, New Delhi, India"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ujjwal Kumar","family":"Choudhary","sequence":"additional","affiliation":[{"name":"Department of Cardiothoracic and Vascular Surgery, CNC, AIIMS, New Delhi, India"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"276","reference":[{"key":"R1-20250528","doi-asserted-by":"crossref","first-page":"686","DOI":"10.1016\/j.jvs.2003.08.023","article-title":"Methemoglobinemia: An unusual cause of postoperative cyanosis","volume":"39","author":"Anderson","year":"2004","journal-title":"J Vasc Surg"},{"key":"R2-20250528","doi-asserted-by":"crossref","first-page":"434","DOI":"10.1373\/clinchem.2004.035154","article-title":"Laboratory assessment of oxygenation in methemoglobinemia","volume":"51","author":"Haymond","year":"2005","journal-title":"Clin Chem"},{"key":"R3-20250528","doi-asserted-by":"crossref","first-page":"646","DOI":"10.1016\/S0196-0644(99)70167-8","article-title":"Methemoglobinemia: Etiology, pharmacology, and clinical management","volume":"34","author":"Wright","year":"1999","journal-title":"Ann Emerg Med"},{"key":"R4-20250528","doi-asserted-by":"crossref","first-page":"291","DOI":"10.1111\/j.1365-2044.1991.tb11501.x","article-title":"Potential errors in pulse oximetry. III: Effects of interferences, dyes, dyshaemoglobins and other pigments","volume":"46","author":"Ralston","year":"1991","journal-title":"Anaesthesia"},{"key":"R5-20250528","first-page":"845","article-title":"Pulse oximetry in methemoglobinemia","volume":"143","author":"Watcha","year":"1989","journal-title":"Am J Dis Child"},{"key":"R6-20250528","doi-asserted-by":"crossref","first-page":"112","DOI":"10.1097\/00000542-198901000-00021","article-title":"Effects of methemoglobinemia on pulse oximetry and mixed venous oximetry","volume":"70","author":"Barker","year":"1989","journal-title":"Anesthesiology"},{"key":"R7-20250528","first-page":"76","article-title":"Methemoglobinemia in a young man","volume":"35","author":"Hamirani","year":"2008","journal-title":"Tex Heart Inst J"},{"key":"R8-20250528","doi-asserted-by":"crossref","first-page":"837","DOI":"10.1213\/ane.0b013e318187c4b1","article-title":"Methemoglobinemia related to local anesthetics: A summary of 242 episodes","volume":"108","author":"Guay","year":"2009","journal-title":"Anesth Analg"},{"key":"R9-20250528","doi-asserted-by":"crossref","first-page":"181","DOI":"10.1016\/0002-9149(85)90324-8","article-title":"Association of methemoglobinemia and intravenous nitroglycerin administration","volume":"55","author":"Kaplan","year":"1985","journal-title":"Am J Cardiol"},{"key":"R10-20250528","doi-asserted-by":"crossref","first-page":"170","DOI":"10.1067\/mje.2003.5","article-title":"Benzocaine-induced methemoglobinemia: Experience from a high-volume transesophageal echocardiography laboratory","volume":"16","author":"Novaro","year":"2003","journal-title":"J Am Soc Echocardiogr"}],"container-title":["Annals of Cardiac Anaesthesia"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.ovid.com\/00660469-201720020-00029","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,8,26]],"date-time":"2026-08-26T20:08:28Z","timestamp":1787774908000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.ovid.com\/00660469-201720020-00029"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2017,4]]},"references-count":10,"journal-issue":{"issue":"2","published-print":{"date-parts":[[2017]]}},"URL":"https:\/\/doi.org\/10.4103\/aca.aca_34_17","relation":{},"ISSN":["0971-9784","0974-5181"],"issn-type":[{"value":"0971-9784","type":"print"},{"value":"0974-5181","type":"electronic"}],"subject":[],"published":{"date-parts":[[2017,4]]}}}