{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,14]],"date-time":"2026-10-14T13:46:38Z","timestamp":1791985598857,"version":"4.4.0"},"reference-count":16,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"4","license":[{"start":{"date-parts":[[2026,10,1]],"date-time":"2026-10-01T00:00:00Z","timestamp":1790812800000},"content-version":"unspecified","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by-nc-nd\/4.0"}],"content-domain":{"domain":["lww.com","ovid.com"],"crossmark-restriction":true},"short-container-title":[],"published-print":{"date-parts":[[2026,10]]},"abstract":"<jats:title>ABSTRACT<\/jats:title>\n                  <jats:sec>\n                    <jats:title>Objective:<\/jats:title>\n                    <jats:p>To compare the effectiveness and safety of a novel geometric landmark technique with the conventional palpation technique for central venous cannulation.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Study Design:<\/jats:title>\n                    <jats:p>Comparative observational study.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Place and Duration of the Study:<\/jats:title>\n                    <jats:p>This study was conducted at National Medical Centre (NMC) from January 01, 2025 to June 30, 2025.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Methods:<\/jats:title>\n                    <jats:p>\n                      A total of 100 adult patients requiring central venous cannulation were enrolled and allocated into two groups based on the technique used. Group A (\n                      <jats:italic toggle=\"yes\">n<\/jats:italic>\n                      = 50) underwent cannulation using the geometric landmark method, while Group B (\n                      <jats:italic toggle=\"yes\">n<\/jats:italic>\n                      = 50) underwent cannulation using the conventional palpation technique. First-attempt success rate was the main outcome. Secondary outcomes were the number of attempts, arterial puncture, and change of technique. SPSS software was used for analysis. Chi-square test was used to compare categorical variables whereas the Mann-Whitney U test was applied to the non-normally distributed continuous variables. A P value of less than 0.05 was considered statistically significant.\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results:<\/jats:title>\n                    <jats:p>\n                      First-attempt success was significantly higher in the geometric landmark group compared to the palpation group (98% vs. 86%;\n                      <jats:italic toggle=\"yes\">P<\/jats:italic>\n                      = 0.027). The geometric landmark technique was associated with fewer cannulation attempts (mean 1.00 \u00b1 0.00 vs. 1.18 \u00b1 0.57;\n                      <jats:italic toggle=\"yes\">P<\/jats:italic>\n                      = 0.012). Arterial puncture occurred in one patient (2%) in each group, with no statistically significant difference (\n                      <jats:italic toggle=\"yes\">P<\/jats:italic>\n                      = 1.000). Technique change was required in one patient (2%) in each group, with no statistically significant difference between the two techniques (\n                      <jats:italic toggle=\"yes\">P<\/jats:italic>\n                      = 1.000). The two groups had similar baseline demographic and clinical characteristics.\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusion:<\/jats:title>\n                    <jats:p>The geometric landmark technique significantly improves first-attempt success and reduces the number of cannulation attempts compared with the conventional palpation method while maintaining a comparable safety profile. This technique represents a practical and cost-effective alternative for central venous cannulation, particularly in resource-limited settings.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.4103\/aca.aca_43_26","type":"journal-article","created":{"date-parts":[[2026,10,12]],"date-time":"2026-10-12T17:00:14Z","timestamp":1791824414000},"page":"503-509","update-policy":"https:\/\/doi.org\/10.1097\/lww.0000000000001000","source":"Crossref","is-referenced-by-count":0,"title":["Comparison of a Novel Geometric Landmark Method Versus Conventional Palpation Technique for Central Venous Cannulation: A Comparative Observational Study of Two Techniques"],"prefix":"10.4103","volume":"29","author":[{"given":"Muhammad Arslan","family":"Zahid","sequence":"first","affiliation":[{"name":"Department of Anesthesiology, National Medical Centre, Karachi, Pakistan"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ahmed Arslan","family":"Shahbaz","sequence":"additional","affiliation":[{"name":"Department of Anesthesiology, National Medical Centre, Karachi, Pakistan"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Dawood Hasan","family":"Khan","sequence":"additional","affiliation":[{"name":"Department of Cardiac Surgery, Sheikh Zayed Hospital, Rahim Yar Khan, Pakistan"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Maqsood Ahmed","family":"Siddiqui","sequence":"additional","affiliation":[{"name":"Department of Cardiac Surgery, Ghulam Muhammad Mahar Medical College, Sukkur, Pakistan"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Wajid","family":"Ali","sequence":"additional","affiliation":[{"name":"Department of Anesthesiology, General Practice Hospital, Islamabad, Pakistan"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Akbar","family":"Mistry","sequence":"additional","affiliation":[{"name":"Department of Anesthesiology, SIUT (Congenital Cardiac Surgery Section), Karachi, Pakistan"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"276","published-online":{"date-parts":[[2026,10,12]]},"reference":[{"key":"R1-20261014","doi-asserted-by":"crossref","first-page":"1327","DOI":"10.2147\/AMEP.S439243","article-title":"Comparing the utility of landmark-palpation guided to ultrasound-guided teaching methodologies for subclavian central venous access using a formalin-embalmed cadaver model","volume":"14","author":"Lundgreen Mason","year":"2023","journal-title":"Adv Med Educ Pract"},{"key":"R2-20261014","doi-asserted-by":"crossref","first-page":"642","DOI":"10.1097\/CCM.0000000000005819","article-title":"Real-time ultrasound guidance as compared with landmark technique for subclavian central venous cannulation: A systematic review and meta-analysis with trial sequential analysis","volume":"51","author":"Zawadka","year":"2023","journal-title":"Crit Care Med"},{"key":"R3-20261014","doi-asserted-by":"crossref","first-page":"391","DOI":"10.1016\/j.medin.2023.01.003","article-title":"Arterial cannulation in adult critical care patients: A comparative study between ultrasound guidance and palpation technique","volume":"47","author":"Gutte","year":"2023","journal-title":"Med Intensiva (Engl Ed)"},{"key":"R4-20261014","doi-asserted-by":"crossref","first-page":"872","DOI":"10.1186\/s12891-025-09156-z","article-title":"Comparative analysis of intraoperative fluoroscopic vs. Anatomical landmark positioning methods in MPFL reconstruction for recurrent patellar dislocation","volume":"26","author":"Lin","year":"2025","journal-title":"BMC Musculoskelet Disord"},{"key":"R5-20261014","doi-asserted-by":"crossref","first-page":"3443","DOI":"10.1053\/j.jvca.2025.09.002","article-title":"A retrospective observational cohort study of ultrasound-guided subclavian central venous cannulation in children undergoing cardiac surgery","volume":"39","author":"Shtayer","year":"2025","journal-title":"J Cardiothorac Vasc Anesth"},{"key":"R6-20261014","doi-asserted-by":"crossref","first-page":"31","DOI":"10.1186\/s12871-024-02415-x","article-title":"Evaluation of a modified ultrasound-assisted technique for mid-thoracic epidural placement: A prospective observational study","volume":"24","author":"Huang","year":"2024","journal-title":"BMC Anesthesiol"},{"key":"R8-20261014","doi-asserted-by":"crossref","first-page":"273","DOI":"10.4103\/njcp.njcp_371_24","article-title":"Comparative study of preprocedure and real-time ultrasound-guided combined spinal epidural anesthesia in obese patients","volume":"28","author":"Anand","year":"2025","journal-title":"Niger J Clin Pract"},{"key":"R9-20261014","doi-asserted-by":"crossref","first-page":"1303","DOI":"10.1186\/s12909-025-07899-w","article-title":"The effect of reversed screen orientation versus standard orientation in bedside ultrasound on vascular access skill acquisition: A cadaver study","volume":"25","author":"K\u00f6ksal","year":"2025","journal-title":"BMC Med Educ"},{"key":"R10-20261014","doi-asserted-by":"crossref","first-page":"268","DOI":"10.1186\/s13023-024-03278-8","article-title":"A horizontal and perpendicular interlaminar approach for intrathecal nusinersen injection in patients with spinal muscular atrophy and scoliosis: An observational study","volume":"19","author":"Huang","year":"2024","journal-title":"Orphanet J Rare Dis"},{"key":"R11-20261014","doi-asserted-by":"crossref","first-page":"109164","DOI":"10.5492\/wjccm.v14.i4.109164","article-title":"Intra-arterial catheters: An evidence-based review of device design, function and application","volume":"14","author":"Yaxley","year":"2025","journal-title":"World J Crit Care Med"},{"key":"R12-20261014","doi-asserted-by":"crossref","first-page":"83","DOI":"10.1186\/s13005-025-00558-x","article-title":"Intraoperative CT evaluation of repositioning accuracy in zygomaticomaxillary complex fractures: 1-point versus multiple-point fixation","volume":"21","author":"Sakkas","year":"2025","journal-title":"Head Face Med"},{"key":"R13-20261014","doi-asserted-by":"crossref","first-page":"686","DOI":"10.3390\/healthcare11050686","article-title":"Validity and reliability of a non-radiographic postural analysis device based on an RGB-depth camera comparing EOS 3D imaging: A prospective observational study","volume":"11","author":"Lee","year":"2023","journal-title":"Healthcare (Basel)"},{"key":"R14-20261014","doi-asserted-by":"crossref","first-page":"1593","DOI":"10.1007\/s00192-022-05444-7","article-title":"A novel anchoring system for pelvic organ prolapse repair: An observational study","volume":"34","author":"van Raalte","year":"2023","journal-title":"Int Urogynecol J"},{"key":"R15-20261014","first-page":"309","article-title":"MetaAcuPoint: Metahuman-generated synthetic data for hand acupoint localization","volume":"13","author":"Guruge","year":"2025","journal-title":"Healthcare (Basel)"},{"key":"R16-20261014","doi-asserted-by":"crossref","first-page":"38984","DOI":"10.1038\/s41598-025-22823-4","article-title":"Reassessing chest compression sites in pediatric cardiopulmonary resuscitation without ventilatory support using echocardiographic assessment: A prospective observational study","volume":"15","author":"Suh","year":"2025","journal-title":"Sci Rep"},{"key":"R17-20261014","doi-asserted-by":"crossref","first-page":"461","DOI":"10.1186\/s12882-025-04374-y","article-title":"UK Kidney Association Clinical Practice Guideline on vascular access for haemodialysis","volume":"26","author":"Aitken","year":"2025","journal-title":"BMC Nephrol"}],"container-title":["Annals of Cardiac Anaesthesia"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.ovid.com\/10.4103\/aca.aca_43_26","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,10,14]],"date-time":"2026-10-14T13:01:02Z","timestamp":1791982862000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.ovid.com\/10.4103\/aca.aca_43_26"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,10]]},"references-count":16,"journal-issue":{"issue":"4","published-print":{"date-parts":[[2026]]}},"URL":"https:\/\/doi.org\/10.4103\/aca.aca_43_26","relation":{},"ISSN":["0971-9784","0974-5181"],"issn-type":[{"value":"0971-9784","type":"print"},{"value":"0974-5181","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,10]]},"assertion":[{"value":"2026-02-06","name":"received","label":"Received","group":{"name":"publication_history","label":"Publication History"}},{"value":"2026-04-15","name":"accepted","label":"Accepted","group":{"name":"publication_history","label":"Publication History"}}]}}